Time-resolved fluorescence imaging of solvent interactions in microfluidic devices

被引:44
作者
Benninger, RKP [1 ]
Hofmann, O
McGinty, J
Requejo-Isidro, J
Munro, I
Neil, MAA
deMello, AJ
French, PMW
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Phys, London SW7 2AZ, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Chem, London SW7 2AZ, England
关键词
D O I
10.1364/OPEX.13.006275
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present the application of wide-field time-resolved fluorescence imaging methods for the study of solvent interactions and mixing in microfluidic devices. Time-resolved imaging of fluorescence polarization anisotropy allows us to image the local viscosity of fluorescein in three dimensions in order to directly monitor solvent mixing within a microfluidic channel. This provides a viscosity image acquisition time of the order of minutes, and has been applied to a steady-state laminar flow configuration. To image dynamic fluid mixing in real-time, we demonstrate high-speed fluorescence lifetime imaging at 12.3 Hz applied to DASPI, which directly exhibits a solvent viscosity-dependant fluorescence lifetime. These two methods facilitate a high degree of quantification of microfluidic flow in 3-D and/or at high speed, providing a tool for studying fluid dynamics and for developing enhanced microfluidic assays. (C) 2005 Optical Society of America.
引用
收藏
页码:6275 / 6285
页数:11
相关论文
共 25 条
[1]   High frame rate fluorescence lifetime imaging [J].
Agronskaia, AV ;
Tertoolen, L ;
Gerritsen, HC .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (14) :1655-1662
[2]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[3]   CARBOCYANINE DYE ORIENTATION IN RED-CELL MEMBRANE STUDIED BY MICROSCOPIC FLUORESCENCE POLARIZATION [J].
AXELROD, D .
BIOPHYSICAL JOURNAL, 1979, 26 (03) :557-573
[4]   Fluorescence imaging of two-photon linear dichroism:: Cholesterol depletion disrupts molecular orientation in cell membranes [J].
Benninger, RKP ;
Önfelt, B ;
Neil, MAA ;
Davis, DM ;
French, PMW .
BIOPHYSICAL JOURNAL, 2005, 88 (01) :609-622
[5]   Dynamic fluorescence anisotropy imaging microscopy in the frequency domain (rFLIM) [J].
Clayton, AHA ;
Hanley, QS ;
Arndt-Jovin, DJ ;
Subramaniam, V ;
Jovin, TM .
BIOPHYSICAL JOURNAL, 2002, 83 (03) :1631-1649
[6]   Whole-field optically sectioned fluorescence lifetime imaging [J].
Cole, MJ ;
Siegel, J ;
Webb, SED ;
Jones, R ;
Dowling, K ;
French, PMW ;
Lever, MJ ;
Sucharov, LOD ;
Neil, MAA ;
Juskaitis, R ;
Wilson, T .
OPTICS LETTERS, 2000, 25 (18) :1361-1363
[7]   High resolution time-domain fluorescence lifetime imaging for biomedical applications [J].
Dowling, K ;
Dayel, MJ ;
Hyde, SCW ;
French, PMW ;
Lever, MJ ;
Hares, JD ;
Dymoke-Bradshaw, AKL .
JOURNAL OF MODERN OPTICS, 1999, 46 (02) :199-209
[8]   2-D fluorescence lifetime imaging using a time-gated image intensifier [J].
Dowling, K ;
Hyde, SCW ;
Dainty, JC ;
French, PMW ;
Hares, JD .
OPTICS COMMUNICATIONS, 1997, 135 (1-3) :27-31
[9]   Real-time time-domain fluorescence lifetime imaging including single-shot acquisition with a segmented optical image intensifier [J].
Elson, DS ;
Munro, I ;
Requejo-Isidro, J ;
McGinty, J ;
Dunsby, C ;
Galletly, N ;
Stamp, GW ;
Neil, MAA ;
Lever, MJ ;
Kellett, PA ;
Dymoke-Bradshaw, A ;
Hares, J ;
French, PMW .
NEW JOURNAL OF PHYSICS, 2004, 6 :1-13
[10]  
GRANT D, 2005, FOC MICR JEN GERM 20