Real-time time-domain fluorescence lifetime imaging including single-shot acquisition with a segmented optical image intensifier

被引:57
作者
Elson, DS
Munro, I
Requejo-Isidro, J
McGinty, J
Dunsby, C
Galletly, N
Stamp, GW
Neil, MAA
Lever, MJ
Kellett, PA
Dymoke-Bradshaw, A
Hares, J
French, PMW
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Phys, Photon Grp, London SW7 2AZ, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Histopathol, Div Investigat Sci, London W12 0NN, England
[3] Univ London Imperial Coll Sci Technol & Med, Dept Bioengn, London SW7 2AZ, England
[4] Kentech Instruments Ltd, Unit 9, Didcot OX11 9AG, Oxon, England
来源
NEW JOURNAL OF PHYSICS | 2004年 / 6卷
关键词
D O I
10.1088/1367-2630/6/1/180
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
High-speed (video-rate) fluorescence lifetime imaging (FLIM) is reported using two different time-domain approaches based on gated optical image intensifier technology. The first approach utilizes a rapidly switchable variable delay generator with sequential image acquisition, while the second employs a novel segmented gated optical imager to acquire lifetime maps in a single shot. Lifetimes are fitted using both a non-linear least-squares fit analysis and the rapid lifetime determination method. Monte Carlo simulations were used to optimize the acquisition parameters and a comparison between theory and experiment is presented. The importance of single-shot imaging to minimize the deleterious impact of sample movements is highlighted. Real-time FLIM movies of multi-well plate samples and tissue autofluorescence are presented.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 26 条
[1]   High frame rate fluorescence lifetime imaging [J].
Agronskaia, AV ;
Tertoolen, L ;
Gerritsen, HC .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (14) :1655-1662
[2]   AN ERROR ANALYSIS OF THE RAPID LIFETIME DETERMINATION METHOD FOR THE EVALUATION OF SINGLE EXPONENTIAL DECAYS [J].
BALLEW, RM ;
DEMAS, JN .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :30-33
[3]   Fluorescence lifetime imaging by time-correlated single-photon counting [J].
Becker, W ;
Bergmann, A ;
Hink, MA ;
König, K ;
Benndorf, K ;
Biskup, C .
MICROSCOPY RESEARCH AND TECHNIQUE, 2004, 63 (01) :58-66
[4]   Optimized gating scheme for rapid lifetime determinations of single-exponential luminescence lifetimes [J].
Chan, SP ;
Fuller, ZJ ;
Demas, JN ;
DeGraff, BA .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4486-4490
[5]   Dynamic fluorescence anisotropy imaging microscopy in the frequency domain (rFLIM) [J].
Clayton, AHA ;
Hanley, QS ;
Arndt-Jovin, DJ ;
Subramaniam, V ;
Jovin, TM .
BIOPHYSICAL JOURNAL, 2002, 83 (03) :1631-1649
[6]   Time-resolved fluorescence imaging in biology and medicine [J].
Cubeddu, R ;
Comelli, D ;
D'Andrea, C ;
Taroni, P ;
Valentini, G .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2002, 35 (09) :R61-R76
[7]   Fluorescence lifetime imaging with picosecond resolution for biomedical applications [J].
Dowling, K ;
Dayel, MJ ;
Lever, MJ ;
French, PMW ;
Hares, JD ;
Dymoke-Bradshaw, AKL .
OPTICS LETTERS, 1998, 23 (10) :810-812
[8]  
ELSON D, 2004, PHOTOCHEM PHOTOBIOL, V3, P1
[9]   Fluorescence lifetime system for microscopy and multiwell plate imaging with a blue picosecond diode laser [J].
Elson, DS ;
Siegel, J ;
Webb, SED ;
Lévêque-Fort, S ;
Lever, MJ ;
French, PMW ;
Lauritsen, K ;
Wahl, M ;
Erdmann, R .
OPTICS LETTERS, 2002, 27 (16) :1409-1411
[10]   FLUORESCENCE LIFETIME IMAGING MICROSCOPY (FLIM) - SPATIAL-RESOLUTION OF MICROSTRUCTURES ON THE NANOSECOND TIME-SCALE [J].
GADELLA, TWJ ;
JOVIN, TM ;
CLEGG, RM .