Separation of a breast cancer cell line from human blood using a quadrupole magnetic flow sorter

被引:41
作者
Nakamura, M
Decker, K
Chosy, J
Comella, K
Melnik, K
Moore, L
Lasky, LC
Zborowski, M
Chalmers, JJ
机构
[1] Ohio State Univ, Dept Chem Engn, Koffolt Labs 125, Columbus, OH 43210 USA
[2] Ohio State Univ, Dept Pathol, Columbus, OH 43210 USA
[3] Cleveland Clin Fdn, Dept Biomed Engn, Cleveland, OH 44195 USA
[4] Amer Red Cross, Richard M Ross Cord Blood Bank, Columbus, OH 43205 USA
关键词
D O I
10.1021/bp010109q
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
We have developed a quadrupole magnetic flow sorter (QMS) to facilitate high-throughput binary cell separation. Optimized QMS operation requires the adjustment of three flow parameters based on the immunomagnetic characteristics of the target cell sample. To overcome the inefficiency of semiempirical operation/optimization of QMS flow parameters, a theoretical model of the QMS sorting process was developed. Application of this model requires measurement of the magnetophoretic mobility distribution of the cell sample by the cell tracking velocimetry (CTV) technique developed in our laboratory. In this work, the theoretical model was experimentally tested using breast carcinoma cells (HCC1954) overexpressing the HER-2/neu gene, and peripheral blood leukocytes (PBLs). The magnetophoretic mobility distribution of immunomagnetically labeled HCC1954 cells was measured using the CTV technique, and then theoretical predictions of sorting recoveries were calculated. Mean magnetophoretic mobilities of (1-3) x 10(-4) mm(3)/(T A s) were obtained depending on the labeling conditions. Labeled HCC1954 cells were mixed with unlabeled PBLs to form a "spiked" sample to be separated by the QMS. Fractional recoveries of-cells for different flow parameters were examined and compared with theoretical predictions. Experimental results showed that the theoretical model accurately predicted fractional recoveries of HCC1954 cells. High-throughput (3.29 x 10(5) cells/s) separations with high recovery (0.89) of HCC1954 cells were achieved.
引用
收藏
页码:1145 / 1155
页数:11
相关论文
共 27 条
[21]   Use of magnetic techniques for the isolation of cells [J].
Safarik, I ;
Safaríková, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 722 (1-2) :33-53
[22]   Use of a tumor-cell enrichment column for the enhanced detection of minimal residual disease in the BM or apheresis peripheral blood transplant products of breast-cancer patients [J].
Shammo, JM ;
Smith, SL ;
Bennett, MV ;
Lee, HW ;
Ostrander, A ;
Ross, AA ;
Williams, SF .
CYTOTHERAPY, 1999, 1 (05) :367-376
[23]  
SHAPIRO HM, 1995, PRACTICAL FLOW CYTOM, P217
[24]  
Sun LP, 1998, CYTOMETRY, V33, P469, DOI 10.1002/(SICI)1097-0320(19981201)33:4<469::AID-CYTO11>3.0.CO
[25]  
2-6
[26]   Flow rate optimization for the quadrupole magnetic cell sorter [J].
Williams, PS ;
Zborowski, M ;
Chalmers, JJ .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3799-3807
[27]   Continuous cell separation using novel magnetic quadrupole flow sorter [J].
Zborowski, M ;
Sun, LP ;
Moore, LR ;
Williams, PS ;
Chalmers, JJ .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1999, 194 (1-3) :224-230