Improving the sensitivity of a quartz crystal microbalance for biosensing by using porous gold

被引:17
作者
van Noort, D [1 ]
Rani, R
Mandenius, CF
机构
[1] Linkoping Univ, Div Biotechnol, S-58182 Linkoping, Sweden
[2] Linkoping Univ, Dept Phys & Measurement Technol, Lab Appl Opt, S-58183 Linkoping, Sweden
关键词
quartz crystal microbalance; affinity biosensor; porous gold; myoglobin;
D O I
10.1007/s006040170066
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A quartz crystal microbalance can be used as a biosensor if biological receptor molecules (ligands) are attached to the crystal. To improve the sensitivity, the surface area of the gold electrodes on the crystal was increased by rendering the electrodes porous. This increased the response up to a factor of 3. A protein model system with human anti-myoglobin as ligand and sheep skeletal myoglobin at different concentrations as analyte was used. The quartz crystal was mounted in a flow-cell, where immobilisation, binding and regeneration of the surface were carried out. The kinetics of the model system was monitored under various experimental conditions.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 23 条
[1]  
ASIMOV, 1964, INTELLIGENT MANS GUI
[2]  
BUTTRY DA, 1991, ELECTROANALYTICAL CH, P1
[3]  
CARTER RM, 1995, ANAL LETT, V28, P1379
[4]   A piezoelectric quartz crystal sensor for the determination of coagulation time in plasma and whole blood [J].
Cheng, TJ ;
Chang, HC ;
Lin, TM .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (02) :147-156
[5]   Energy dissipation kinetics for protein and antibody-antigen adsorption under shear oscillation on a quartz crystal microbalance [J].
Hook, F ;
Rodahl, M ;
Brzezinski, P ;
Kasemo, B .
LANGMUIR, 1998, 14 (04) :729-734
[6]   CHEMISORPTION OF L-CYSTEINE AND 3-MERCAPTOPROPIONIC ACID ON GOLD AND COPPER SURFACES - AN INFRARED REFLECTION ABSORPTION STUDY [J].
IHS, A ;
LIEDBERG, B .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1991, 144 (01) :282-292
[7]   SELF-ASSEMBLY OF MEDIATOR-MODIFIED ENZYME IN POROUS GOLD-BLACK ELECTRODE FOR BIOSENSING [J].
IMAMURA, M ;
HARUYAMA, T ;
KOBATAKE, E ;
IKARIYAMA, Y ;
AIZAWA, M .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) :113-116
[8]  
JOHANSEN K, 1999, UNPUB
[9]  
Jonsson U., 1992, ADV BIOSENSORS, V2, P291, DOI DOI 10.1016/B978-1-85617-161-8.50079-3
[10]   A HIGH-STABILITY QUARTZ-CRYSTAL MICROBALANCE ELECTRODE FOR SIMULTANEOUS SOLUTION-PHASE ELECTROCHEMISTRY MICROGRAVITOMETRY [J].
KOMPLIN, GC ;
SCHLEIFER, F ;
PIETRO, WJ .