A simulation study of ion kinetic energies during resonant excitation in a stretched ion trap

被引:43
作者
Splendore, M
Londry, FA
March, RE
Morrison, RJS
Perrier, P
Andre, J
机构
[1] TRENT UNIV,DEPT CHEM,PETERBOROUGH,ON K9J 7B8,CANADA
[2] MONASH UNIV,DEPT CHEM,MELBOURNE,VIC 3168,AUSTRALIA
[3] UNIV AIX MARSEILLE 1,INST UNIV SYST THERM,F-13397 MARSEILLE 20,FRANCE
来源
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES | 1996年 / 156卷 / 1-2期
关键词
stretched quadrupole ion trap; resonant excitation; ion trajectory simulation; simulation; absorption curve;
D O I
10.1016/S0168-1176(96)04408-4
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The trajectories of ions confined individually in a commercial quadrupolar ion trap of stretched geometry and subjected to resonant excitation have been calculated. During resonant excitation, the average ion kinetic energy increases when the ion secular frequency motion is in phase with the resonant excitation and decreases when the phases are opposed. The temporal variation of ion kinetic energy when subjected to resonant excitation exhibits two cyclical forms, one with low ion kinetic energy and one with relatively high ion kinetic energy. In the low ion kinetic energy cyclical form is characterized by smoothly rounded profiles at time intervals of ca. 2 ms; the high ion kinetic energy cyclical form is characterized by sharply pointed crests at time intervals of ca. 1 ms. In the low ion kinetic energy cyclical form, the maximum instantaneous ion kinetic energy attained is ca. 16 eV and corresponds to axial excursions of up to 3 mm. In the high ion kinetic energy cyclical form, the maximum instantaneous ion kinetic energy attained increases in value to in excess of 70 eV, with an axial excursion of 6.2 mm, as the resonant excitation frequency is increased. At a critical frequency, epsilon(c), there is a discontinuous change from the high to the low ion kinetic energy cyclical form. The maximum instantaneous ion kinetic energy, KE(max), varies as a simple quadratic function of the axial excursion of the ion, so that ion kinetic energy is derived from the main storage field within the ion trap. The asymmetric form observed in the experimental resonance absorption curve, obtained as a function of resonant frequency, has been reproduced qualitatively and the asymmetry can be ascribed to the transition between the two cyclical forms of the temporal variation of ion kinetic energy.
引用
收藏
页码:11 / 29
页数:19
相关论文
共 48 条
[21]   COMPUTER-SIMULATION OF SINGLE-ION TRAJECTORIES IN PAUL-TYPE ION TRAPS [J].
LONDRY, FA ;
ALFRED, RL ;
MARCH, RE .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (09) :687-705
[22]  
LOURIS J, 1992, P 40 ASMS C MASS SPE, P1003
[23]   ION ISOLATION AND SEQUENTIAL STAGES OF MASS-SPECTROMETRY IN A QUADRUPOLE ION TRAP MASS-SPECTROMETER [J].
LOURIS, JN ;
BRODBELTLUSTIG, JS ;
COOKS, RG ;
GLISH, GL ;
VANBERKEL, GJ ;
MCLUCKEY, SA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 96 (02) :117-137
[24]  
March R. E., 1995, PRACTICAL ASPECTS IO, VII
[25]   SOME THOUGHTS ON THE STRETCHED ION TRAP [J].
MARCH, RE ;
LONDRY, FA ;
ALFRED, RL .
ORGANIC MASS SPECTROMETRY, 1992, 27 (10) :1151-1152
[26]   RESONANCE EXCITATION OF IONS STORED IN A QUADRUPOLE ION TRAP .1. A SIMULATION STUDY [J].
MARCH, RE ;
MCMAHON, AW ;
LONDRY, FA ;
ALFRED, RL ;
TODD, JFJ ;
VEDEL, F .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 95 (02) :119-156
[27]   RESONANCE EXCITATION OF IONS STORED IN A QUADRUPOLE ION TRAP .2. FURTHER SIMULATION STUDIES [J].
MARCH, RE ;
MCMAHON, AW ;
ALLINSON, ET ;
LONDRY, FA ;
ALFRED, RL ;
TODD, JFJ ;
VEDEL, F .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 99 (1-2) :109-124
[28]  
MARCH RE, 1991, INT J MASS SPECTROM, V110, P159, DOI 10.1016/0168-1176(91)80026-J
[29]   KINETIC-ENERGY EFFECTS IN AN ION ENSEMBLE SUBJECTED TO MASS-SELECTIVE ISOLATION AND RESONANCE EXCITATION - A SIMULATION STUDY [J].
MARCH, RE ;
WEIR, MR ;
TKACZYK, M ;
LONDRY, FA ;
ALFRED, RL ;
FRANKLIN, AM ;
TODD, JFJ .
ORGANIC MASS SPECTROMETRY, 1993, 28 (05) :499-509
[30]   MASS-SELECTIVE ISOLATION OF IONS STORED IN A QUADRUPOLE ION-TRAP .2. A SIMULATION STUDY OF CONSECUTIVE ISOLATION [J].
MARCH, RE ;
TKACYZK, M ;
LONDRY, FA ;
ALFRED, RL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1993, 125 (01) :9-32