Results of a multicenter retrospective implantable cardioverter-defibrillator registry of pediatric and congenital heart disease patients

被引:261
作者
Berul, Charles I. [1 ]
Van Hare, George F. [2 ,3 ]
Kertesz, Naomi J. [4 ]
Dubin, Anne M. [2 ]
Cecchin, Frank [1 ]
Collins, Kathryn K. [3 ]
Cannon, Bryan C. [4 ]
Alexander, Mark E. [1 ]
Triedman, John K. [1 ]
Walsh, Edward P. [1 ]
Friedman, Richard A. [4 ]
机构
[1] Harvard Univ, Childrens Hosp, Sch Med, Boston, MA 02115 USA
[2] Stanford Univ, Palo Alto, CA 94304 USA
[3] Univ Calif San Francisco, San Francisco, CA 94143 USA
[4] Baylor Coll Med, Texas Childrens Hosp, Houston, TX 77030 USA
关键词
D O I
10.1016/j.jacc.2008.01.033
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We sought to determine the implications of implantable cardioverter-defibrillator (ICD) placement in children and patients with congenital heart disease (CHD). Background There is increasing frequency of ICD use in pediatric and CHD patients. Until recently, prospective registry enrollment of ICD patients was not available, and children and CHO patients account for only a small percentage of ICD recipients. Therefore, we retrospectively obtained collaborative data from 4 pediatric centers, aiming to identify implant characteristics, shock frequency, and complications in this unique population. Methods Databases from 4 centers were collated in a blinded fashion. Demographic information, implant electrical parameters, appropriate and inappropriate shock data, and complications were recorded for all implants from 1992 to 2004. Results A total of 443 patients were included, with a median age of 16 years (range 0 to 54 years) and median weight of 61 kg (range 2 to 130 kg), with 69% having structural heart disease. The most common diagnoses were tetralogy of Fallot (19%) and hypertrophic cardiomyopathy (14%). Implant indication was primary prevention in 52%. Shock data were available on 409 patients, of whom 105 (26%) received appropriate shocks (mean 4 shocks/patient, range I to 29 shocks/patient). Inappropriate shocks occurred in 87 of 409 patients (21%), with a mean of 6 per patient (range I to 60), mainly attributable to lead failure (14%), sinus or atria] tachy-cardias (9%), and/or oversensing (4%). Conclusions Children and CHD ICD recipients have significant appropriate and inappropriate shock frequencies. Optimizing programming, medical management, and compliance may diminish inappropriate shocks. Despite concerns regarding generator recalls, lead failure remains the major cause of inappropriate shocks, complications, and system malfunction in children. Prospective assessment of ICID usage in this population may identify additional important factors in pediatric and CHD patients.
引用
收藏
页码:1685 / 1691
页数:7
相关论文
共 30 条
[1]   Implications of implantable cardioverter defibrillator therapy in congenital heart disease and pediatrics [J].
Alexander, ME ;
Cecchin, F ;
Walsh, EP ;
Triedman, JK ;
Bevilacqua, LM ;
Berul, CI .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (01) :72-76
[2]   The use of implantable cardioverter-defibrillators (ICD) in children and adolescents [J].
Apitz, C. ;
Gass, M. ;
Doernberger, V. ;
Kuehlkamp, V. ;
Hofbeck, M. .
KLINISCHE PADIATRIE, 2006, 218 (05) :270-275
[3]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[4]   Minimally invasive Cardioverter defibrillator implantation for children: An animal model and pediatric case report [J].
Berul, CI ;
Triedman, JK ;
Forbess, J ;
Bevilacqua, LM ;
Alexander, ME ;
Dahlby, D ;
Gilkerson, JO ;
Walsh, EP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (12) :1789-1794
[5]   A randomized study of the prevention of sudden death in patients with coronary artery disease [J].
Buxton, AE ;
Lee, KL ;
Fisher, JD ;
Josephson, ME ;
Prystowsky, EN ;
Hafley, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) :1882-1890
[6]   Innovative techniques for placement of implantable cardioverter-defibrillator leads in patients with limited venous access to the heart [J].
Cannon, BC ;
Friedman, RA ;
Fenrich, AL ;
Fraser, CD ;
McKenzie, ED ;
Kertesz, NJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (02) :181-187
[7]   Implantable cardioverter defibrillator lead complications and laser extraction in children and young adults with congenital heart disease: Implications for implantation and management [J].
Cooper, JM ;
Stephenson, EA ;
Berul, CI ;
Walsh, EP ;
Epstein, LM .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (04) :344-349
[8]   Psychosocial factors and quality of life in children and adolescents with implantable cardioverter-defibrillators [J].
DeMaso, DR ;
Lauretti, A ;
Spieth, L ;
Van der Feen, JR ;
Jay, KS ;
Gauvreau, K ;
Walsh, EP ;
Berul, CI .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (05) :582-587
[9]   Implantable cardioverter defibrillator (ICD) in children [J].
Eicken, A ;
Kolb, C ;
Lange, S ;
Brodherr-Heberlein, S ;
Zrenner, B ;
Schreiber, C ;
Hess, J .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2006, 107 (01) :30-35
[10]   Implantable cardioverter defibrillator therapy in children with long QT syndrome [J].
Goel, AK ;
Berger, S ;
Pelech, A ;
Dhala, A .
PEDIATRIC CARDIOLOGY, 2004, 25 (04) :370-378