A model is presented describing the effects of dead time and mass bias correction factor uncertainties, flicker noise, and counting statistics on isotope ratio measurement precision using inductively coupled plasma mass spectrometry (ICPMS) with a single collector. Noise spectral analysis is exploited to enable estimation of the flicker noise parameters. For the instrument used, the flicker noise component exhibited a fairly weak frequency (f) dependence (proportional to f (-0.33 +/-0.12)), but was directly proportional to the total number of counts, Q. As white noise, determined by counting statistics, is given by Q(0.5), the isotope ratio measurement uncertainties will actually cease to improve when Q exceeds a certain threshold. This would suggest that flicker noise could become the limiting factor for the precision with which isotope ratios can be determined by ICPMS, However, under most experimental conditions, uncertainties associated with mass discrimination and dead time correction factors are decisive. For ratios up to similar to 22 (In-115/In-113), optimum major isotope count rates are generally below 0.3 MHz, for which precision in the mass discrimination factor is limiting. The model derived could be used as a starting point for determining optimum conditions and understanding the limitations of single-collector ICPMS for precise isotope ratio measurements.
引用
收藏
页码:2911 / 2919
页数:9
相关论文
共 26 条
  • [1] A model for calculating dead time and mass discrimination correction factors from inductively coupled plasma mass spectrometry calibration curves
    Appelblad, PK
    Baxter, DC
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (05) : 557 - 560
  • [2] Barnes RM, 1996, FRESEN J ANAL CHEM, V355, P433
  • [3] Ultratrace and precise isotope analysis by double-focusing sector field inductively coupled plasma mass spectrometry
    Becker, JS
    Dietze, HJ
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) : 1057 - 1063
  • [4] Characterisation and correction of instrumental bias in inductively coupled plasma quadrupole mass spectrometry for accurate measurement of lead isotope ratios
    Begley, IS
    Sharp, BL
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (04) : 395 - 402
  • [5] NONSPECTROSCOPIC INTERELEMENT INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    GILLSON, GR
    DOUGLAS, DJ
    FULFORD, JE
    HALLIGAN, KW
    TANNER, SD
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (14) : 1472 - 1474
  • [6] Applications of multiple collector-ICPMS to cosmochemistry, geochemistry, and paleoceanography
    Halliday, AN
    Lee, DC
    Christensen, JN
    Rehkamper, M
    Yi, W
    Luo, XZ
    Hall, CM
    Ballentine, CJ
    Pettke, T
    Stirling, C
    [J]. GEOCHIMICA ET COSMOCHIMICA ACTA, 1998, 62 (06) : 919 - 940
  • [7] HELD A, 2001, 19744EN EUR EUR COMM, P1
  • [8] Heumann KG, 1998, J ANAL ATOM SPECTROM, V13, P1001
  • [9] NOISE IN INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY - SOME PRELIMINARY MEASUREMENTS
    INCE, AT
    WILLIAMS, JG
    GRAY, AL
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (06) : 899 - &
  • [10] Ingle J.D., 1988, SPECTROCHEMICAL ANAL, P135