Ivabradine Versus Metoprolol for Heart Rate Reduction Before Coronary Computed Tomography Angiography

被引:37
作者
Pichler, Philipp [1 ,2 ]
Pichler-Cetin, Emel [3 ]
Vertesich, Markus [1 ]
Mendel, Helmuth [2 ]
Sochor, Heinz [1 ]
Dock, Wolfgang [2 ]
Syeda, Bonni [1 ]
机构
[1] Med Univ Vienna, Div Cardiol, Dept Internal Med 2, Vienna, Austria
[2] Privatklin Josefstadt, Dept Radiol, Vienna, Austria
[3] Hanusch Hosp, Dept Cardiol, Vienna, Austria
关键词
DIAGNOSTIC-ACCURACY; BRADYCARDIAC AGENT; IMAGE QUALITY; BETA-BLOCKADE; EFFICACY; RABBIT;
D O I
10.1016/j.amjcard.2011.08.025
中图分类号
R5 [内科学];
学科分类号
100201 [内科学];
摘要
Several studies have demonstrated the correlation of heart rate (HR) and image quality in coronary computed tomography angiography. Beta-blocker administration is critical because of its negative inotropic effect. Ivabradine is a selective HR-lowering agent that exclusively inhibits the If current in sinoatrial node cells without having any effect on cardiac contractility or atrioventricular conduction. A total of 120 patients were randomized to oral premedication with ivabradine 15 mg or metoprolol 50 mg. HR and blood pressure (BP) were measured before the administration of premedication and immediately before coronary computed tomographic angiography. The mean time between premedication administration and follow-up was 108 +/- 21.5 minutes for ivabradine and 110 +/- 22.2 minutes for metoprolol (p = NS). When comparing groups, there were no significant differences in reduction of HR (-11.83 +/- 8.6 vs 13.20 +/- 7.8 beats/min, p = NS) and diastolic BP (-5.05 +/- 14.2 mm Hg vs 4.08 +/- 10.8 mm Hg, p = NS), whereas the decrease of systolic BP was significantly lower in patients who received ivabradine compared to those in the metoprolol group (-3.95 +/- 13.6 vs -13.65 +/- 17.3 mm Hg, p <0.001). In the subgroup of patients who were receiving long-term a-blocker therapy, significantly stronger HR reduction was achieved with ivabradine (-13.19 +/- 5.4 vs -10.04 +/- 6.0 beats/min, p <0.05), while the decrease in systolic BP was less (-2.00 +/- 13.6 vs -15.04 +/- 20.8 mm Hg, p <0.05) compared to metoprolol. In conclusion, ivabradine decreases HR before coronary computed tomographic angiography sufficiently, with significantly less depression of systolic BP compared to metoprolol. (C) 2012 Elsevier Inc. All rights reserved. (Am J Cardiol 2012;109:169-173)
引用
收藏
页码:169 / 173
页数:5
相关论文
共 19 条
[1]
Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition [J].
Achenbach, Stephan ;
Marwan, Mohamed ;
Ropers, Dieter ;
Schepis, Tiziano ;
Pflederer, Tobias ;
Anders, Katharina ;
Kuettner, Axel ;
Daniel, Werner G. ;
Uder, Michael ;
Lell, Michael M. .
EUROPEAN HEART JOURNAL, 2010, 31 (03) :340-346
[2]
Radiation Dose and Image Quality of Prospective Triggering With Dual-Source Cardiac Computed Tomography [J].
Blankstein, Ron ;
Shah, Amar ;
Pale, Rodrigo ;
Abbara, Suhny ;
Bezerra, Hiram ;
Bolen, Michael ;
Mamuya, Wilfred S. ;
Hoffmann, Udo ;
Brady, Thomas J. ;
Cury, Ricardo C. .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (08) :1168-1173
[3]
Mode of action of bradycardic agent, S 16257, on ionic currents of rabbit sinoatrial node cells [J].
Bois, P ;
Bescond, J ;
Renaudon, B ;
Lenfant, J .
BRITISH JOURNAL OF PHARMACOLOGY, 1996, 118 (04) :1051-1057
[4]
Safety and efficacy of patient preparation with intravenous esmolol before 64-slice computed tomography coronary angiography [J].
Degertekin, Muzaffer ;
Gemici, Gokmen ;
Kaya, Zafer ;
Bayrak, Fatih ;
Guneysu, Tahsin ;
Sevinc, Deniz ;
Mutlu, Bulent ;
Aytaclar, Semih .
CORONARY ARTERY DISEASE, 2008, 19 (01) :33-36
[5]
CHARACTERIZATION OF SINGLE PACEMAKER CHANNELS IN CARDIAC SINOATRIAL NODE CELLS [J].
DIFRANCESCO, D .
NATURE, 1986, 324 (6096) :470-473
[6]
ACUTE AND CHRONIC CARDIAC AND REGIONAL HEMODYNAMIC-EFFECTS OF THE NOVEL BRADYCARDIAC AGENT, S16257, IN CONSCIOUS RATS [J].
GARDINER, SM ;
KEMP, PA ;
MARCH, JE ;
BENNETT, T .
BRITISH JOURNAL OF PHARMACOLOGY, 1995, 115 (04) :579-586
[7]
Guaricci AI, INT J CARDI IN PRESS
[8]
Husmann L, 2008, EUR HEART J, V29, P191, DOI 10.1093/eurheartj/ehm613
[9]
Coronary plaque imaging with 256-slice multidetector computed tomography: interobserver variability of volumetric lesion parameters with semiautomatic plaque analysis software [J].
Klass, Oliver ;
Kleinhans, Susanne ;
Walker, Matthew J. ;
Olszewski, Mark ;
Feuerlein, Sebastian ;
Juchems, Markus ;
Hoffmann, Martin H. K. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (06) :711-720
[10]
Comparison of Diagnostic Accuracy and Radiation Dose Between Prospective Triggering and Retrospective Gated Coronary Angiography by Dual-Source Computed Tomography [J].
Lu, Bin ;
Lu, Jin-Guo ;
Sun, Ming-Li ;
Hou, Zhi-Hui ;
Chen, Xiong-Biao ;
Tang, Xiang ;
Wu, Run-Ze ;
Johnson, Laura ;
Qiao, Shu-Bin ;
Yang, Yue-Jin ;
Jiang, Shi-Liang .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (09) :1278-1284