Evaluation of multitransducer arrays for the determination of organic vapor mixtures

被引:51
作者
Jin, Chunguang [1 ,3 ]
Kurzawski, Petra [4 ]
Hierlemann, Andreas [4 ]
Zellers, Edward T. [1 ,2 ,3 ]
机构
[1] Univ Michigan, Ctr Wireless Integrated MicroSyst, Ann Arbor, MI 48105 USA
[2] Univ Michigan, Dept Chem, Ann Arbor, MI 48105 USA
[3] Univ Michigan, Dept Environm Hlth Sci, Ann Arbor, MI 48105 USA
[4] ETH, Phys Elect Lab, CH-8093 Zurich, Switzerland
关键词
D O I
10.1021/ac0715120
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A study of vapor recognition and quantification by polymer-coated multitransducer (MT) arrays is described. The primary data set consists of experimentally derived sensitivities for 11 organic vapors obtained from 15 microsensors comprising five cantilever, capacitor, and calorimeter devices coated with five different sorptive-polymer films. These are used in Monte Carlo simulations coupled with principal component regression models to assess expected performance. Recognition rates for individual vapors and for vapor mixtures of up to four components are estimated for single-transducer (ST) arrays of up to five sensors and MT arrays of up to 15 sensors. Recognition rates are not significantly improved by including more than five sensors in an W array for any specific analysis, regardless of difficulty. Optimal MT arrays consistently outperform optimal ST arrays of similar size, and with judiciously selected 5-sensor MT arrays, one-third of all possible ternary vapor mixtures are reliably discriminated from their individual components and binary component mixtures, whereas none are reliably determined with any of the ST arrays. Quaternary mixtures could not be analyzed effectively with any of the arrays. A "universal" MT array consisting of eight sensors is defined, which provides the best possible performance for all analytical scenarios. Accurate quantification is predicted for correctly identified vapors.
引用
收藏
页码:227 / 236
页数:10
相关论文
共 64 条
[1]   CONDUCTING POLYMER GAS SENSORS .3. RESULTS FOR 4 DIFFERENT POLYMERS AND 5 DIFFERENT VAPORS [J].
BARTLETT, PN ;
LINGCHUNG, SK .
SENSORS AND ACTUATORS, 1989, 20 (03) :287-292
[2]   THE USE OF MULTISENSOR SYSTEMS IN MONITORING HAZARDOUS ATMOSPHERES [J].
BOTT, B ;
JONES, TA .
SENSORS AND ACTUATORS, 1986, 9 (01) :19-25
[3]   Classification performance of carbon black-polymer composite vapor detector arrays as a function of array size and detector composition [J].
Burl, MC ;
Sisk, BC ;
Vaid, TP ;
Lewis, NS .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (01) :130-149
[4]   Dual-chemiresistor GC detector employing layer-protected metal nanocluster interfaces [J].
Cai, QY ;
Zellers, ET .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3533-3539
[5]   Vapor recognition with an integrated array of polymer-coated flexural plate wave sensors [J].
Cai, QY ;
Park, J ;
Heldsinger, D ;
Hsieh, MD ;
Zellers, ET .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (02) :121-130
[6]   Facile hyphenation of gas chromatography and a microcantilever array sensor for enhanced selectivity [J].
Chapman, Peter J. ;
Vogt, Frank ;
Dutta, Pampa ;
Datskos, Panos G. ;
Devault, Gerald L. ;
Sepaniak, Michael J. .
ANALYTICAL CHEMISTRY, 2007, 79 (01) :364-370
[7]   A method for selecting an optimum sensor array [J].
Chaudry, AN ;
Hawkins, TM ;
Travers, PJ .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (03) :236-242
[8]   CAPACITIVE SENSORS IN CMOS TECHNOLOGY WITH POLYMER COATING [J].
CORNILA, C ;
HIERLEMANN, A ;
LENGGENHAGER, R ;
MALCOVATI, P ;
BALTES, H ;
NOETZEL, G ;
WEIMAR, U ;
GOPEL, W .
SENSORS AND ACTUATORS B-CHEMICAL, 1995, 25 (1-3) :357-361
[9]   Quantitative study of the resolving power of arrays of carbon black-polymer composites in various vapor-sensing tasks [J].
Doleman, BJ ;
Lonergan, MC ;
Severin, EJ ;
Vaid, TP ;
Lewis, NS .
ANALYTICAL CHEMISTRY, 1998, 70 (19) :4177-4190
[10]   Response signatures for nanostructured, optically-probed functionalized microcantilever sensing arrays [J].
Dutta, P ;
Senesac, LR ;
Lavrik, NV ;
Datskos, PG ;
Sepaniak, MJ .
SENSOR LETTERS, 2004, 2 (3-4) :238-245