Facile hyphenation of gas chromatography and a microcantilever array sensor for enhanced selectivity

被引:18
作者
Chapman, Peter J.
Vogt, Frank
Dutta, Pampa
Datskos, Panos G.
Devault, Gerald L.
Sepaniak, Michael J. [1 ]
机构
[1] Univ Tennessee, Dept Chem, Knoxville, TN 37996 USA
[2] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
[3] Y12 Natl Secur Complex, Oak Ridge, TN 37831 USA
关键词
D O I
10.1021/ac061389x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The very simple coupling of a standard, packed-column gas chromatograph with a microcantilever array (MCA) is demonstrated for enhanced selectivity and potential analyte identification in the analysis of volatile organic compounds (VOCs). The cantilevers in MCAs are differentially coated on one side with responsive phases (RPs) and produce bending responses of the cantilevers due to analyte-induced surface stresses. Generally, individual components are difficult to elucidate when introduced to MCA systems as mixtures, although pattern recognition techniques are helpful in identifying single components, binary mixtures, or composite responses of distinct mixtures (e.g., fragrances). In the present work, simple test VOC mixtures composed of acetone, ethanol, and trichloroethylene (TCE) in pentane and methanol and acetonitrile in pentane are first separated using a standard gas chromatograph and then introduced into a MCA flow cell. Significant amounts of response diversity to the analytes in the mixtures are demonstrated across the RP-coated cantilevers of the array. Principal component analysis is used to demonstrate that only three components of a four-component VOC mixture could be identified without mixture separation. Calibration studies are performed, demonstrating a good linear response over 2 orders of magnitude for each component in the primary study mixture. Studies of operational parameters including column temperature, column flow rate, and array cell temperature are conducted. Reproducibility studies of VOC peak areas and peak heights are also carried out showing RSDs of less than 4 and 3%, respectively, for intra-assay studies. Of practical significance is the facile manner by which the hyphenation of a mature separation technique and the burgeoning sensing approach is accomplished, and the potential to use pattern recognition techniques with MCAs as a new type of detector for chromatography with analyte-identifying capabilities.
引用
收藏
页码:364 / 370
页数:7
相关论文
共 41 条
[1]   Micromachined piezoresistive cantilever array with integrated resistive microheater for calorimetry and mass detection [J].
Abedinov, N ;
Grabiec, P ;
Gotszalk, T ;
Ivanov, T ;
Voigt, J ;
Rangelow, IW .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2001, 19 (06) :2884-2888
[2]  
[Anonymous], APPL REGRESSION ANAL
[3]  
ARCHIBALD R, UNPUB ANAL CHIM ACTA
[4]   Chemical detection based on adsorption-induced and photoinduced stresses in microelectromechanical systems devices [J].
Datskos, PG ;
Rajic, S ;
Sepaniak, MJ ;
Lavrik, N ;
Tipple, CA ;
Senesac, LR ;
Datskou, I .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2001, 19 (04) :1173-1179
[5]   Detection of Bacillus subtilis spores using peptide-functionalized cantilever arrays [J].
Dhayal, B ;
Henne, WA ;
Doorneweerd, DD ;
Reifenberger, RG ;
Low, PS .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (11) :3716-3721
[6]   Response signatures for nanostructured, optically-probed functionalized microcantilever sensing arrays [J].
Dutta, P ;
Senesac, LR ;
Lavrik, NV ;
Datskos, PG ;
Sepaniak, MJ .
SENSOR LETTERS, 2004, 2 (3-4) :238-245
[7]   Characterization of ligand-functionalized microcantilevers for metal ion sensing [J].
Dutta, P ;
Chapman, PJ ;
Datskos, PG ;
Sepaniak, MJ .
ANALYTICAL CHEMISTRY, 2005, 77 (20) :6601-6608
[8]   Enantioselective sensors based on antibody-mediated nanomechanics [J].
Dutta, P ;
Tipple, CA ;
Lavrik, NV ;
Datskos, PG ;
Hofstetter, H ;
Hofstetter, O ;
Sepaniak, MJ .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2342-2348
[9]   Health effects of a mixture of indoor air volatile organics, their ozone oxidation products, and stress [J].
Fiedler, N ;
Laumbach, R ;
Kelly-McNeil, K ;
Lioy, P ;
Fan, ZH ;
Zhang, JF ;
Ottenweller, J ;
Ohman-Strickland, P ;
Kipen, H .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2005, 113 (11) :1542-1548
[10]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318