Use of surface electromyography to estimate neck muscle activity

被引:186
作者
Sommerich, CM [1 ]
Joines, SMB
Hermans, V
Moon, SD
机构
[1] N Carolina State Univ, Dept Ind Engn, Raleigh, NC 27695 USA
[2] Vrije Univ Amsterdam, Fac Human Movement Sci, Amsterdam, Netherlands
[3] Duke Univ, Med Ctr, Dept Community & Family Med, Durham, NC USA
关键词
D O I
10.1016/S1050-6411(00)00033-X
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This paper reviews the literature concerning the use of surface electromyography (sEMG) for the study of the neck musculature in response to work and workplace design during light work and semi-static tasks. The paper also draws upon basic research and biomechanical modeling in order to provide methodological recommendations for the use of surface electromyography in this region of the body and to identify areas which require further investigation. The paper includes review and discussion of electrode site location, methods of normalization, data reliability, and factors that can affect sEMG signals from this region, including noise, physiologic artifact, stress, visual deficiencies, and pain. General guidance for maximum exertions with the neck musculature, for sEMG normalization or other purposes, is also included. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:377 / 398
页数:22
相关论文
共 87 条
[41]  
Mayoux-Benhamou M A, 1993, Electromyogr Clin Neurophysiol, V33, P161
[42]  
Meyer J J, 1993, Electromyogr Clin Neurophysiol, V33, P217
[43]   SYMPTOMS OF THE NECK AND UPPER EXTREMITIES IN DENTISTS [J].
MILERAD, E ;
EKENVALL, L .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1990, 16 (02) :129-134
[44]   THE QUANTIFICATION OF EMG NORMALIZATION ERROR [J].
MIRKA, GA .
ERGONOMICS, 1991, 34 (03) :343-352
[45]   ANALYSIS AND MEASUREMENT OF NECK LOADS [J].
MORONEY, SP ;
SCHULTZ, AB ;
MILLER, JAA .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (05) :713-720
[46]   BIOMECHANICAL EVALUATION OF THE EXTENSOR MUSCULATURE OF THE CERVICAL-SPINE [J].
NOLAN, JP ;
SHERK, HH .
SPINE, 1988, 13 (01) :9-11
[47]  
Oberg T, 1993, J Dent Hyg, V67, P257
[48]   Body position effects on sternocleidomastoid and masseter EMG pattern activity in patients undergoing occlusal splint therapy [J].
Ormeno, G ;
Miralles, R ;
Santander, H ;
Casassus, R ;
Ferrer, P ;
Palazzi, C ;
Moya, H .
CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 1997, 15 (04) :300-309
[49]  
PHILLIPS CA, 1984, AVIAT SPACE ENVIR MD, V55, P740
[50]   THE RELATIONSHIP BETWEEN THE ELECTROMYOGRAM-AMPLITUDE AND ISOMETRIC EXTENSION TORQUES OF NECK MUSCLES AT DIFFERENT POSITIONS OF THE CERVICAL-SPINE [J].
QUEISSER, F ;
BLUTHNER, R ;
BRAUER, D ;
SEIDEL, H .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1994, 68 (01) :92-101