Development of a preconcentration unit for a SAW sensor micro array and its use for indoor air quality monitoring

被引:70
作者
Bender, F [1 ]
Barié, N [1 ]
Romoudis, G [1 ]
Voigt, A [1 ]
Rapp, A [1 ]
机构
[1] Forschungszentrum Karlsruhe, Inst Instrumental Anal, D-76021 Karlsruhe, Germany
关键词
SAW sensor array; preconcentration unit (trap); electronic nose; BTXE;
D O I
10.1016/S0925-4005(03)00239-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new surface acoustic wave (SAW) sensor system for continuous monitoring of air quality was developed. The system employs a miniaturized array of eight polymer coated SAW sensors, a preconcentration unit ('trap'), and methods of pattern recognition. Care was taken to minimize both the response times of the sensors and the gas volume of the sensor array. Thus, a small trap with low heat capacity can be used, resulting in low power consumption and rapid thermal desorption. The capabilities of the system are demonstrated by successful discrimination of closely related aromatic compounds (BTXE) in the low- and sub-ppm ranges. Design considerations are made with particular emphasis on the necessities arising from the interplay between sensors, coatings, trap, gas fluidics, and pattern recognition software. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 17 条
  • [1] [Anonymous], ANAL CHEM
  • [2] Avramov I. D., 2000, IEEE EIA INT FREQ CO
  • [3] Investigations on plasma-polymer-coated SAW and STW resonators for chemical gas-sensing applications
    Avramov, ID
    Kurosawa, S
    Rapp, M
    Krawczak, P
    Radeva, EI
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2001, 49 (04) : 827 - 837
  • [4] BAER RL, 1992, ULTRASON, P293, DOI 10.1109/ULTSYM.1992.275993
  • [5] UV crosslinked polysiloxanes as new coating materials for SAW devices with high long-term stability
    Barie, N
    Rapp, M
    Ache, HJ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (02) : 97 - 103
  • [6] Acoustic wave gas sensors
    Cheeke, JDN
    Wang, Z
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 59 (2-3) : 146 - 153
  • [7] Ella Baker - Freedom bound
    Frantz, EO
    [J]. SOUTHERN CULTURES, 2000, 6 (02) : 88 - 89
  • [8] A LOVE PLATE BIOSENSOR UTILIZING A POLYMER LAYER
    GIZELI, E
    GODDARD, NJ
    LOWE, CR
    STEVENSON, AC
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) : 131 - 137
  • [9] GRATE JW, 1993, ANAL CHEM, V65, P987
  • [10] Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconcentrator adsorbent
    Groves, WA
    Zellers, ET
    Frye, GC
    [J]. ANALYTICA CHIMICA ACTA, 1998, 371 (2-3) : 131 - 143