Controlled clinical comparison of BACTEC Plus Anaerobic/F to Standard Anaerobic/F as the anaerobic companion bottle to Plus Aerobic/F medium for culturing blood from adults

被引:18
作者
Wilson, ML
Mirrett, S
Meredith, FT
Weinstein, MP
Scotto, V
Reller, LB
机构
[1] Denver Hlth Med Ctr, Dept Pathol & Lab Serv, Denver, CO 80204 USA
[2] Univ Colorado, Sch Med, Dept Pathol, Denver, CO 80262 USA
[3] Robert Wood Johnson Univ Hosp, Clin Microbiol Lab, New Brunswick, NJ 08901 USA
[4] Robert Wood Johnson Med Sch, Dept Pathol, New Brunswick, NJ 08901 USA
[5] Robert Wood Johnson Med Sch, Dept Med, New Brunswick, NJ 08901 USA
[6] Duke Univ, Med Ctr, Dept Pathol, Durham, NC 27710 USA
[7] Duke Univ, Med Ctr, Dept Med, Durham, NC 27710 USA
[8] Duke Univ, Med Ctr, Clin Microbiol Lab, Durham, NC 27710 USA
关键词
D O I
10.1128/JCM.39.3.983-989.2001
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
To determine the optimal anaerobic companion bottle to pair with BACTEC Plus Aerobic/F medium for recovery of pathogenic microorganisms from adult patients with bacteremia and fungemia, we compared Plus Anaerobic/F bottles with Standard Anaerobic/F bottles, each of which was filled with 4 to 6 mi of blood. The two bottles were paired with a Plus Aerobic/F bottle filled with 8 to 12 mi of blood. A total of 14,011 blood culture sets were obtained. Of these, 11,583 sets were received with all three bottles filled adequately and 12,257 were received with both anaerobic bottles filled adequately. Of 818 clinically important isolates detected in one or both adequately filled anaerobic bottles, significantly more staphylococci (P < 0.001), streptococci (P < 0.005), Escherichia coli isolates (P < 0.02), Klebsiella pneumomiae isolates (P < 0.005), and all microorganisms combined (P < 0.001) were detected in Plus Anaerobic/F bottles. In contrast, significantly more anaerobic gram-negative bacilli were detected in Standard Anaerobic/F bottles (P < 0.05). Of 397 unimicrobial episodes of septicemia, 354 were detected with both pairs, 30 were detected with Plus Aerobic/F-Plus Anaerobic/F pairs only, and 13 were detected,vith Plus Aerobic/F-Standard Anaerobic/F pairs only (P < 0.05). Significantly more episodes of bacteremia caused by members of the family Enterobacteriaceae (P < 0.05) and aerobic and facultative gram-positive bacteria (P < 0.025) were detected with Plus Anaerobic/F bottles only. In a paired-bottle analysis, 810 of 950 isolates were recovered from both pairs, 90 were recovered from Plus Aerobic/F-Plus Anaerobic/F pairs only, and 50 were recovered from Plus Aerobic/F-Standard Anaerobic/F pairs only (P < 0.001). Paired Plus Aerobic/F-Plus Anaerobic/F bottles yielded significantly more staphylococci (P < 0.001), streptococci (P < 0.05), and members of the family Enterobacteriaceae (P < 0.001). We conclude that Plus Anaerobic/F bottles detect more microorganisms and episodes of bacteremia and fungemia than Standard Anaerobic/F bottles as companion bottles to Plus Aerobic/F bottles in the BACTEC 9240 blood culture system.
引用
收藏
页码:983 / 989
页数:7
相关论文
共 30 条
[11]   ANAEROBIC BACTEREMIA - INCIDENCE, PATIENT CHARACTERISTICS, AND CLINICAL-SIGNIFICANCE [J].
LOMBARDI, DP ;
ENGLEBERG, NC .
AMERICAN JOURNAL OF MEDICINE, 1992, 92 (01) :53-60
[12]   Clinical importance of increased sensitivity of BacT/Alert FAN aerobic and anaerobic blood culture bottles [J].
McDonald, LC ;
Fune, J ;
Gaido, LB ;
Weinstein, MP ;
Reimer, LG ;
Flynn, TM ;
Wilson, ML ;
Mirrett, S ;
Reller, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1996, 34 (09) :2180-2184
[13]  
MCNEMAR Q, 1962, PSYCHOL STATISTICS, P209
[14]   RATIONALE FOR SELECTIVE USE OF ANAEROBIC BLOOD CULTURES [J].
MORRIS, AJ ;
WILSON, ML ;
MIRRETT, S ;
RELLER, LB .
JOURNAL OF CLINICAL MICROBIOLOGY, 1993, 31 (08) :2110-2113
[15]   CRITICAL-ASSESSMENT OF BLOOD CULTURE TECHNIQUES - ANALYSIS OF RECOVERY OF OBLIGATE AND FACULTATIVE ANAEROBES, STRICT AEROBIC-BACTERIA, AND FUNGI IN AEROBIC AND ANAEROBIC BLOOD CULTURE BOTTLES [J].
MURRAY, PR ;
TRAYNOR, P ;
HOPSON, D .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (06) :1462-1468
[16]  
Murray PR., 1995, MANUAL CLIN MICROBIO
[17]   INCIDENCE AND CLINICAL-SIGNIFICANCE OF ANAEROBIC BACTEREMIA IN A COMMUNITY-HOSPITAL [J].
PERAINO, VA ;
CROSS, SA ;
GOLDSTEIN, EJC .
CLINICAL INFECTIOUS DISEASES, 1993, 16 :S288-S291
[18]   CONTROLLED CLINICAL-EVALUATION OF BACTEC PLUS AEROBIC/F AND BACT/ALERT AEROBIC FAN BOTTLES FOR DETECTION OF BLOOD-STREAM INFECTIONS [J].
POHLMAN, JK ;
KIRKLEY, BA ;
EASLEY, KA ;
BASILLE, BA ;
WASHINGTON, JA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (11) :2856-2858
[19]   Assessment of the yield of anaerobic blood cultures [J].
Pottumarthy, S ;
Morris, AJ .
PATHOLOGY, 1997, 29 (04) :415-417
[20]   Advantage of combining resin with lytic BACTEC: Blood culture media [J].
Rohner, P ;
Pepey, B ;
Auckenthaler, R .
JOURNAL OF CLINICAL MICROBIOLOGY, 1997, 35 (10) :2634-2638