Integrated hydrogenated amorphous Si photodiode detector for microfluidic bioanalytical devices

被引:124
作者
Kamei, T
Paegel, BM
Scherer, JR
Skelley, AM
Street, RA
Mathies, RA [1 ]
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[2] Xerox Corp, Palo Alto Res Ctr, Palo Alto, CA 94304 USA
关键词
D O I
10.1021/ac0301550
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hydrogenated amorphous silicon (a-Si:H) PIN photodiodes have been developed and characterized as fluorescence detectors for microfluidic analysis devices. A discrete a-Si:H photodiode is first fabricated on a glass substrate and used to detect fluorescent dye standards using conventional confocal microscopy. In this format, the limit of detection for fluorescein flowing in a 50-mum deep channel is 680 pM (S/N = 3). A hybrid integrated detection system consisting of a half-ball lens, a ZnS/YF3 multilayer optical interference filter with a pinhole, and an annular a-Si:H photodiode is also developed that allows the laser excitation to pass up through the central aperture in the detector. Using this integrated detection device, the limit of detection for fluorescein is 17 nM, and DNA fragment sizing and chiral analysis of glutamic acid are successfully performed. The a-Si:H detector exhibits high sensitivity at the emission wavelengths of commonly used fluorescent dyes and is readily microfabricated and integrated at low cost making it ideal for portable microfluidic bioanalyzers and emerging large scale integrated microfluidic technologies.
引用
收藏
页码:5300 / 5305
页数:6
相关论文
共 37 条
[1]   Microfluidic integration on detector arrays for absorption and fluorescence micro-spectrometers [J].
Adams, ML ;
Enzelberger, M ;
Quake, S ;
Scherer, A .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 104 (01) :25-31
[2]   A miniature integrated device for automated multistep genetic assays [J].
Anderson, Rolfe C. ;
Su, Xing ;
Bogdan, Gregory J. ;
Fenton, Jeffery .
NUCLEIC ACIDS RESEARCH, 2000, 28 (12)
[3]  
BABA Y, 2002, MICRO TOTAL ANAL SYS
[4]   BIOMOLECULES - ORIGINS OF HOMOCHIRALITY [J].
BADA, JL .
NATURE, 1995, 374 (6523) :594-595
[5]   A search for endogenous amino acids in martian meteorite ALH84001 [J].
Bada, JL ;
Glavin, DP ;
McDonald, GD ;
Becker, L .
SCIENCE, 1998, 279 (5349) :362-365
[6]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[7]   An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications [J].
Chabinyc, ML ;
Chiu, DT ;
McDonald, JC ;
Stroock, AD ;
Christian, JF ;
Karger, AM ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2001, 73 (18) :4491-4498
[8]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[9]   Microfabricated 384-lane capillary array electrophoresis bioanalyzer for ultrahigh-throughput genetic analysis [J].
Emrich, CA ;
Tian, HJ ;
Medintz, IL ;
Mathies, RA .
ANALYTICAL CHEMISTRY, 2002, 74 (19) :5076-5083
[10]   An integrated microfabricated cell sorter [J].
Fu, AY ;
Chou, HP ;
Spence, C ;
Arnold, FH ;
Quake, SR .
ANALYTICAL CHEMISTRY, 2002, 74 (11) :2451-2457