A new gas chromatography/mass spectrometry (GC/MS) system was designed and evaluated which we have named 'Supersonic GC/MS'. It is based on a modification of a commercially available GC/MS system to include a supersonic molecular beam (SMB) MS interface. In this system the standard electron ionization (EI) ion source was replaced with a fly-through EI ion source mounted in the path of the SMB. A hyperthermal surface ionization (HSI) ion source combined with a 90 degrees ion mirror (for the EI-produced ions) was also added, and placed inside the quadrupole mass analyzer in place of its original EI ion source. The 'Supersonic GC/MS' system requires 18 cm added bench space plus the addition of an air-cooled 60 L/s diffusion pump and a 537 L/min rotary pump. The system is user friendly since all the gas flow rates, heated zones, sampling and data analysis are performed the same way as the original system and are computer-controlled via the original software. Similar EI sensitivity was obtained as with the original system for hexachlorobenzene and octafluoronaphthalene, while improved EI detection limits were demonstrated for methyl stearate and eicosane due to the significant enhancement of their molecular ion abundances. A GC/MS detection limit of 500 ag for pyrene was demonstrated using HSI. Good supersonic expansion cooling was achieved with large alkanes, despite the use of a rotary pump at the nozzle chamber instead of a diffusion pump. High temperature GC/MS analysis was demonstrated for large polycyclic aromatic hydrocarbons (PAHs) including ovalene and decacyclene (ten rings). Library searches with EI mass spectra are demonstrated, and it is explained why the enhancement of the molecular ion actually improves the library search in most cases. The analysis of large phthalate esters is also described, and the improvement obtained is shown to originate from their enhanced molecular and high mass fragment ions. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:811 / 820
页数:10
相关论文
共 40 条
  • [1] ELECTRON-IMPACT AND HYPERTHERMAL SURFACE-IONIZATION MASS-SPECTROMETRY IN SUPERSONIC MOLECULAR-BEAMS
    AMIRAV, A
    [J]. ORGANIC MASS SPECTROMETRY, 1991, 26 (01): : 1 - 17
  • [2] A direct sample introduction device for mass spectrometry studies and gas chromatography mass spectrometry analyses
    Amirav, A
    Dagan, S
    [J]. EUROPEAN MASS SPECTROMETRY, 1997, 3 (02): : 105 - 111
  • [3] Megabore versus microbore as the optimal column for fast gas chromatography mass spectrometry
    Amirav, A
    Tzanani, N
    Wainhaus, SB
    Dagan, S
    [J]. EUROPEAN MASS SPECTROMETRY, 1998, 4 (01): : 7 - 13
  • [4] ELECTRON-IMPACT MASS-SPECTROMETRY IN SUPERSONIC MOLECULAR-BEAMS
    AMIRAV, A
    DANON, A
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 97 (01): : 107 - 113
  • [5] AMIRAV A, 1998, ADV MASS SPECTROM, V14, P529
  • [6] BRUMLEY WC, 1994, J AOAC INT, V77, P1230
  • [7] Dagan S, 1996, J AM SOC MASS SPECTR, V7, P737, DOI 10.1016/1044-0305(96)80519-8
  • [8] Surface ionization mass spectrometry of drugs in the thermal and hyperthermal energy range - A comparative study
    Dagan, S
    Amirav, A
    Fuju, T
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1995, 151 (2-3): : 159 - 165
  • [9] Fast gas chromatography mass spectrometry analysis of drugs in urine with hyperthermal surface ionization in supersonic molecular beams
    Dagan, S
    Amirav, A
    [J]. EUROPEAN MASS SPECTROMETRY, 1998, 4 (01): : 15 - 21
  • [10] FAST, HIGH-TEMPERATURE AND THERMOLABILE GC MS IN SUPERSONIC MOLECULAR-BEAMS
    DAGAN, S
    AMIRAV, A
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 133 (2-3): : 187 - 210