Amperometric determination of live Escherichia coli using antibody-coated paramagnetic beads

被引:52
作者
Boyaci, IH [1 ]
Aguilar, ZP [1 ]
Hossain, M [1 ]
Halsall, HB [1 ]
Seliskar, CJ [1 ]
Heineman, WR [1 ]
机构
[1] Hacettepe Univ, Dept Food Engn, TR-06532 Ankara, Turkey
关键词
immunoassay; amperometric detection; paramagnetic beads; Escherichia coli; beta-galactosidase;
D O I
10.1007/s00216-005-3263-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Detecting and enumerating fecal coliforms, especially Escherichia coli, as indicators of fecal contamination, are essential for the quality control of supplied and recreational waters. We have developed a sensitive, inexpensive, and small-volume amperometric detection method for E. coli beta-galactosidase by bead-based immunoassay. The technique uses biotin-labeled capture antibodies (Ab) immobilized on paramagnetic microbeads that have been functionalized with streptavidin (bead-Ab). The bead-Ab conjugate captures E. coli from solution. The captured E. coli is incubated in Luria Bertani (LB) broth medium with the added inducer isopropyl beta-D-thiogalactopyranoside (IPTG). The induced beta-galactosidase converts p-aminophenyl beta-D-galactopyranoside (PAPG) into p-aminophenol (PAP), which is measured by amperometry using a gold rotating disc electrode. A good linear correlation (R-2=0.989) was obtained between log cfu mL(-1) E. coli and the time necessary to product a specific concentration of PAP. Amperometric detection enabled determination of 2x10(6)supercript stop cfu mL(-1) E. coli within a 30 min incubation period, and the total analysis time was less than 1 h. It was also possible to determine as few as 20 cfu mL(-1) E. coli under optimized conditions within 6-7 h. This process may be easily adapted as an automated portable bioanalytical device for the rapid detection of live E. coli.
引用
收藏
页码:1234 / 1241
页数:8
相关论文
共 39 条
[21]   Combined phage typing and amperometric detection of released enzymatic activity for the specific identification and quantification of bacteria [J].
Neufeld, T ;
Schwartz-Mittelmann, A ;
Biran, D ;
Ron, EZ ;
Rishpon, J .
ANALYTICAL CHEMISTRY, 2003, 75 (03) :580-585
[22]   Rapid detection of Escherichia coli in water by a culture-based amperometric method [J].
Pérez, F ;
Tryland, I ;
Mascini, M ;
Fiksdal, L .
ANALYTICA CHIMICA ACTA, 2001, 427 (02) :149-154
[23]   Immunomagnetic separation with mediated flow injection analysis amperometric detection of viable Escherichia coli O157 [J].
Pérez, FG ;
Mascini, M ;
Tothill, IE ;
Turner, APF .
ANALYTICAL CHEMISTRY, 1998, 70 (11) :2380-2386
[24]   Use of PNA oligonucleotides for the in situ detection of Escherichia coli in water [J].
Prescott, AM ;
Fricker, CR .
MOLECULAR AND CELLULAR PROBES, 1999, 13 (04) :261-268
[25]   Small volume bead assay for ovalbumin with electrochemical detection [J].
Purushothama, S ;
Kradtap, S ;
Wijayawardhana, CA ;
Halsall, HB ;
Heineman, WR .
ANALYST, 2001, 126 (03) :337-341
[26]   ASSAY FOR BETA-GLUCURONIDASE IN SPECIES OF THE GENUS ESCHERICHIA AND ITS APPLICATIONS FOR DRINKING-WATER ANALYSIS [J].
RICE, EW ;
ALLEN, MJ ;
BRENNER, DJ ;
EDBERG, SC .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1991, 57 (02) :592-593
[27]  
Ruan C, 2002, T ASAE, V45, P249, DOI 10.13031/2013.7853
[28]   Rapid detection, identification, and enumeration of Escherichia coli cells in municipal water by chemiluminescent in situ hybridization [J].
Stender, H ;
Broomer, AJ ;
Oliveira, K ;
Perry-O'Keefe, H ;
Hyldig-Nielsen, JJ ;
Sage, A ;
Coull, J .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2001, 67 (01) :142-147
[29]   Comparison of ATP and in vivo bioluminescence for assessing the efficiency of immunomagnetic sorbents for live Escherichia coli O157:H7 cells [J].
Sun, W ;
Khosravi, F ;
Albrechtsen, H ;
Brovko, LY ;
Griffiths, MW .
JOURNAL OF APPLIED MICROBIOLOGY, 2002, 92 (06) :1021-1027
[30]  
SWAMINATHAN B, 1994, ANNU REV MICROBIOL, V48, P401, DOI 10.1146/annurev.micro.48.1.401