Portal imaging

被引:54
作者
Langmack, KA [1 ]
机构
[1] Lincoln Cty Hosp, Dept Phys Med, Lincoln, England
关键词
D O I
10.1259/bjr.74.885.740789
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Portal imaging is the acquisition of images with a radiotherapy beam. Imaging theory suggests that the quality of portal images could be much higher if the efficiency of the imaging media in detecting radiation could be improved. Introduction of new media (films and electronic portal imaging devices) has confirmed this by markedly increasing the quality of portal images. Images from these devices can then be used to verify a patient's treatment. Geometric verification requires the portal image to be registered with a reference image. Dosimetric verification requires the portal imager to be calibrated for dose. This review gives a brief overview of the current areas of interest in portal imaging: imaging theory; imaging media, film and electronic portal imaging devices; image registration; and dosimetry using these devices.
引用
收藏
页码:789 / 804
页数:16
相关论文
共 174 条
[1]   Physical characteristics of a commercial electronic portal imaging device [J].
Althof, VGM ;
deBoer, JCJ ;
Huizenga, H ;
Stroom, JC ;
Visser, AG ;
Swanenburg, BN .
MEDICAL PHYSICS, 1996, 23 (11) :1845-1855
[2]   A QUANTITATIVE ASSESSMENT OF PORTAL FILM CONTRAST AS A FUNCTION OF BEAM ENERGY [J].
AMOLS, HI ;
REINSTEIN, LE ;
LAGUEUX, B .
MEDICAL PHYSICS, 1986, 13 (05) :711-716
[3]   Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation [J].
Antonuk, LE ;
ElMohri, Y ;
Siewerdsen, JH ;
Yorkston, J ;
Huang, W ;
Scarpine, VE ;
Street, RA .
MEDICAL PHYSICS, 1997, 24 (01) :51-70
[4]   Initial performance evaluation of an indirect-detection, active matrix flat-panel imager (AMFPI) prototype for megavoltage imaging [J].
Antonuk, LE ;
El-Mohri, Y ;
Huang, WD ;
Jee, KW ;
Siewerdsen, JH ;
Maolinbay, M ;
Scarpine, VE ;
Sandler, H ;
Yorkston, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (02) :437-454
[5]   DEMONSTRATION OF MEGAVOLTAGE AND DIAGNOSTIC-X-RAY IMAGING WITH HYDROGENATED AMORPHOUS-SILICON ARRAYS [J].
ANTONUK, LE ;
BOUDRY, J ;
HUANG, WD ;
MCSHAN, DL ;
MORTON, EJ ;
YORKSTON, J ;
LONGO, MJ ;
STREET, RA .
MEDICAL PHYSICS, 1992, 19 (06) :1455-1466
[6]  
ANTONUK LE, 1998, AAPM MED PHYSICS MON, V24, P371
[7]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[8]   USE OF STORAGE PHOSPHOR IMAGING PLATES IN PORTAL IMAGING AND HIGH-ENERGY RADIOGRAPHY - THE INTENSIFYING EFFECT OF METALLIC SCREENS ON THE SENSITIVITY [J].
BARNEA, G ;
NAVON, E ;
GINZBURG, A ;
POLITCH, J ;
ROEHRIG, H ;
DICK, CE ;
PLACIOUS, RC .
MEDICAL PHYSICS, 1991, 18 (03) :432-438
[9]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[10]   AUTOMATIC VERIFICATION OF RADIATION-FIELD SHAPE USING DIGITAL PORTAL IMAGES [J].
BIJHOLD, J ;
GILHUIJS, KGA ;
VANHERK, M .
MEDICAL PHYSICS, 1992, 19 (04) :1007-1014