Portal imaging

被引:54
作者
Langmack, KA [1 ]
机构
[1] Lincoln Cty Hosp, Dept Phys Med, Lincoln, England
关键词
D O I
10.1259/bjr.74.885.740789
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Portal imaging is the acquisition of images with a radiotherapy beam. Imaging theory suggests that the quality of portal images could be much higher if the efficiency of the imaging media in detecting radiation could be improved. Introduction of new media (films and electronic portal imaging devices) has confirmed this by markedly increasing the quality of portal images. Images from these devices can then be used to verify a patient's treatment. Geometric verification requires the portal image to be registered with a reference image. Dosimetric verification requires the portal imager to be calibrated for dose. This review gives a brief overview of the current areas of interest in portal imaging: imaging theory; imaging media, film and electronic portal imaging devices; image registration; and dosimetry using these devices.
引用
收藏
页码:789 / 804
页数:16
相关论文
共 174 条
[51]   AN ALGORITHM FOR AUTOMATIC-ANALYSIS OF PORTAL IMAGES - CLINICAL-EVALUATION FOR PROSTATE TREATMENTS [J].
GILHUIJS, KGA ;
ELGAYED, AAH ;
VANHERK, M ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :261-268
[52]   Automatic three-dimensional inspection of patient setup in radiation therapy using portal images, simulator images, and computed tomography data [J].
Gilhuijs, KGA ;
vandeVen, PJH ;
vanHerk, M .
MEDICAL PHYSICS, 1996, 23 (03) :389-399
[53]   OPTIMIZATION OF AUTOMATIC PORTAL IMAGE-ANALYSIS [J].
GILHUIJS, KGA ;
TOUW, A ;
VANHERK, M ;
VIJLBRIEF, RE .
MEDICAL PHYSICS, 1995, 22 (07) :1089-1099
[54]   Automatic setup deviation measurements with electronic portal images for pelvic fields [J].
Girouard, LM ;
Pouliot, J ;
Maldague, X ;
Zaccarin, A .
MEDICAL PHYSICS, 1998, 25 (07) :1180-1185
[55]   Dosimetric properties of the Theraview™ fluoroscopic electronic portal imaging device [J].
Glendinning, AG ;
Bonnett, DE .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (869) :517-530
[56]  
Goretzky E J, 1992, Can J Med Radiat Technol, V23, P117
[57]   THE USE OF STORAGE PHOSPHORS FOR PORTAL IMAGING IN RADIATION-THERAPY - THERAPISTS PERCEPTION OF IMAGE QUALITY [J].
GUR, D ;
DEUTSCH, M ;
FUHRMAN, CR ;
CLAYTON, PA ;
WEISER, JC ;
ROSENTHAL, MS ;
BUKOVITZ, AG .
MEDICAL PHYSICS, 1989, 16 (01) :132-136
[58]  
Hamilton C S, 1991, Clin Oncol (R Coll Radiol), V3, P90, DOI 10.1016/S0936-6555(05)81170-7
[59]   SUPERVOLTAGE BEAM FILMS [J].
HAMMOUDAH, MM ;
HENSCHKE, UK .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 2 (5-6) :571-577
[60]   Extraction of primary signal from EPIDs using only forward convolution [J].
Hansen, VN ;
Swindell, W ;
Evans, PM .
MEDICAL PHYSICS, 1997, 24 (09) :1477-1484