OPTIMIZATION OF AUTOMATIC PORTAL IMAGE-ANALYSIS

被引:34
作者
GILHUIJS, KGA
TOUW, A
VANHERK, M
VIJLBRIEF, RE
机构
[1] Department of Radiotherapy, Netherlands Cancer Institute (Antoni van Leeuwenhoek Huis), 1066 CX, Amsterdam
关键词
PORTAL IMAGING; IMAGE PROCESSING; ANALYSIS OF VARIANCE;
D O I
10.1118/1.597610
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to quantify and optimize the performance of an automatic portal image analysis procedure under clinical conditions and to compare the performance with that of human operators. A new method, based on analysis of variance, is introduced to quantify the clinical performance of portal image analysis tools in terms of systematic and random variations. The automatic portal image analysis procedure is based on chamfer matching. Two image enhancement techniques have been investigated in the automatic procedure: morphological top-hat (MTH) transformation and multiscale medial axis (MMA) transformation. The performance of these enhancements was quantified and optimized as a function of filter size using images obtained from clinical treatment. All images used for this study were obtained from pelvic treatment fields by means of an electronic portal imaging device. The random variations in the alignment of AP fields are typically 0.5 mm and 0.5 degrees (1 SD) for both the human operators and the optimized automatic analysis procedure. Random variations in the alignment of lateral pelvic fields are typically twice as large for all operators. MMA enhancement yields smaller random variations than MTH enhancement for lateral fields, but the differences are marginal for AP fields. The optimized automatic analysis procedure has a success rate ranging from 99% for AP large fields to 96% for lateral fields and 85% for AP boost fields. The accuracy of the method is comparable with the accuracy of the human operators for most investigated fields. For lateral boost fields and simultaneous boost fields, the random variations of the automatic analysis are typically two times larger than the variations of the human operators. Automatic analysis is 4 to 20 times faster than human operators yielding a large reduction in work load.
引用
收藏
页码:1089 / 1099
页数:11
相关论文
共 26 条
[1]  
BALTER J, 1990, INT J RADIAT ONCOL, V19, P86
[2]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[3]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[4]   AUTOMATIC VERIFICATION OF RADIATION-FIELD SHAPE USING DIGITAL PORTAL IMAGES [J].
BIJHOLD, J ;
GILHUIJS, KGA ;
VANHERK, M .
MEDICAL PHYSICS, 1992, 19 (04) :1007-1014
[5]   MAXIMIZING SETUP ACCURACY USING PORTAL IMAGES AS APPLIED TO A CONFORMAL BOOST TECHNIQUE FOR PROSTATIC-CANCER [J].
BIJHOLD, J ;
LEBESQUE, JV ;
HART, AAM ;
VIJLBRIEF, RE .
RADIOTHERAPY AND ONCOLOGY, 1992, 24 (04) :261-271
[6]  
BIJHOLD J, 1991, PHYS MED BIOL, V12, P1665
[7]   A REVIEW OF ELECTRONIC PORTAL IMAGING DEVICES (EPIDS) [J].
BOYER, AL ;
ANTONUK, L ;
FENSTER, A ;
VANHERK, M ;
MEERTENS, H ;
MUNRO, P ;
REINSTEIN, LE ;
WONG, J .
MEDICAL PHYSICS, 1992, 19 (01) :1-16
[8]   INTERACTIVE USE OF ONLINE PORTAL IMAGING IN PELVIC RADIATION [J].
DENEVE, W ;
VANDENHEUVEL, F ;
COGHE, M ;
VERELLEN, D ;
DEBEUKELEER, M ;
ROELSTRAETE, A ;
DEROOVER, P ;
THON, L ;
STORME, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03) :517-524
[9]   METHODS FOR FULLY AUTOMATED VERIFICATION OF PATIENT SET-UP IN EXTERNAL-BEAM RADIOTHERAPY WITH POLYGON SHAPED FIELDS [J].
EILERTSEN, K ;
SKRETTING, A ;
TENNVASSAS, TL .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (06) :993-1012
[10]   THE MULTISCALE MEDIAL AXIS AND ITS APPLICATIONS IN IMAGE REGISTRATION [J].
FRITSCH, DS ;
PIZER, SM ;
MORSE, BS ;
EBERLY, DH ;
LIU, A .
PATTERN RECOGNITION LETTERS, 1994, 15 (05) :445-452