Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging

被引:67
作者
Kim, YK
Lee, JM [1 ]
Kim, CS
Chung, GH
Kim, CY
Kim, IH
机构
[1] Chonbuk Natl Univ Hosp & Med Sch, Dept Diagnost Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul, South Korea
[4] Chonbuk Natl Univ Hosp & Med Sch, Dept Gen Surg, Seoul, South Korea
[5] Chonbuk Natl Univ Hosp & Med Sch, Dept Internal Med, Seoul, South Korea
关键词
liver; neoplasm; magnetic resonance imaging; contrast agents;
D O I
10.1007/s00330-004-2570-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare the diagnostic performance of gadobenate dimeglumine (GdBOPTA)-enhanced MR imaging, including dynamic phases and one-hour delayed phase, versus superparamagnetic iron oxide (SPIO)-enhanced imaging for detection of liver metastases. Twenty-three patients with 59 liver metastases underwent Gd-BOPTA-enhanced MR imaging (unenhanced, arterial, portal, equilibrium and one-hour delayed phase) using three-dimensional volumetric interpolated imaging and SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences on a 1.5-T unit. Three observers independently interpreted the three sets of images, i.e. Gd-BOPTA-enhanced dynamic MRI (set 1), delayed phase imaging (set 2) and SPIO-enhanced MRI (set 3). Diagnostic accuracy was evaluated using the alternative-free response receiver operating chracteristic (ROC) analysis. Sensitivity and positive predictive value were also evaluated. The mean accuracy (Az values) and sensitivity of Gd-BOPTA-enhanced delayed phase imaging (0.982, 95.5%) were comparable to those of SPIO-enhanced imaging (0.984, 97.2%). In addition, Az values and sensitivities of both imaging sets were significantly higher than those of Gd-BOPTA-enhanced dynamic images (0.826, 77.4%: p<0.05). There was no significant difference in the positive predictive value among the three image sets. Gd-BOPTA-enhanced delayed phase imaging showed comparable diagnostic performance to SPIO-enhanced imaging for the detection of liver metastases, and had a better diagnostic performance than Gd-BOPTA-enhanced dynamic images.
引用
收藏
页码:220 / 228
页数:9
相关论文
共 34 条
[1]   LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING [J].
BELLIN, MF ;
ZAIM, S ;
AUBERTON, E ;
SARFATI, G ;
DURON, JJ ;
KHAYAT, D ;
GRELLET, J .
RADIOLOGY, 1994, 193 (03) :657-663
[2]   Focal malignant hepatic lesions: MR imaging enhanced with gadolinium benzyloxypropionictetra-acetate (BOPTA) - Preliminary results of phase II clinical application [J].
Caudana, R ;
Morana, G ;
Pirovano, GP ;
Nicoli, N ;
Portuese, A ;
Spinazzi, A ;
DiRito, R ;
Pistolesi, GF .
RADIOLOGY, 1996, 199 (02) :513-520
[3]   Gadolinium chelates with weak binding to serum proteins - A new class of high-efficiency, general purpose contrast agents for magnetic resonance imaging [J].
Cavagna, FM ;
Maggioni, F ;
Castelli, PM ;
Dapra, M ;
Imperatori, LG ;
Lorusso, V ;
Jenkins, BG .
INVESTIGATIVE RADIOLOGY, 1997, 32 (12) :780-796
[4]   FREE-RESPONSE METHODOLOGY - ALTERNATE ANALYSIS AND A NEW OBSERVER-PERFORMANCE EXPERIMENT [J].
CHAKRABORTY, DP ;
WINTER, LHL .
RADIOLOGY, 1990, 174 (03) :873-881
[5]   Do arterial phase helical CT images improve detection or characterization of colorectal liver metastases? [J].
Chen, IY ;
Katz, DS ;
Jeffrey, RB ;
Daniel, BL ;
Li, KCP ;
Beaulieu, CF ;
Mindelzun, RE ;
Yao, D ;
Olcott, EW .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (03) :391-397
[6]   Detection of liver metastases: Comparison of gadobenate dimeglumine-enhanced and ferumoxides-enhanced MR imaging examinations [J].
Del Frate, C ;
Bazzocchi, M ;
Mortele, KJ ;
Zuiani, C ;
Londero, V ;
Como, G ;
Zanardi, R ;
Ros, PR .
RADIOLOGY, 2002, 225 (03) :766-772
[7]   HEPATIC TUMORS - DETECTION AND CHARACTERIZATION AT 1-T MR-IMAGING ENHANCED WITH AMI-25 [J].
DENYS, A ;
ARRIVE, L ;
SERVOIS, V ;
DUBRAY, B ;
NAJMARK, D ;
SIBERT, A ;
MENU, Y .
RADIOLOGY, 1994, 193 (03) :665-669
[8]   Surgical treatment of liver metastases by radiofrequency ablation, resection, or in combination [J].
Evrard, S ;
Becouarn, Y ;
Fonck, M ;
Brunet, R ;
Mathoulin-Pelissier, S ;
Picot, V .
EJSO, 2004, 30 (04) :399-406
[9]   IRON-OXIDE ENHANCED MR-IMAGING OF THE LIVER AND SPLEEN - REVIEW OF THE 1ST-5 YEARS [J].
FERRUCCI, JT ;
STARK, DD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) :943-950
[10]  
Fusai G, 2003, Colorectal Dis, V5, P2, DOI 10.1046/j.1463-1318.2003.00410.x