Detection of liver metastases: gadobenate dimeglumine-enhanced three-dimensional dynamic phases and one-hour delayed phase MR imaging versus superparamagnetic iron oxide-enhanced MR imaging

被引:67
作者
Kim, YK
Lee, JM [1 ]
Kim, CS
Chung, GH
Kim, CY
Kim, IH
机构
[1] Chonbuk Natl Univ Hosp & Med Sch, Dept Diagnost Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul, South Korea
[3] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul, South Korea
[4] Chonbuk Natl Univ Hosp & Med Sch, Dept Gen Surg, Seoul, South Korea
[5] Chonbuk Natl Univ Hosp & Med Sch, Dept Internal Med, Seoul, South Korea
关键词
liver; neoplasm; magnetic resonance imaging; contrast agents;
D O I
10.1007/s00330-004-2570-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare the diagnostic performance of gadobenate dimeglumine (GdBOPTA)-enhanced MR imaging, including dynamic phases and one-hour delayed phase, versus superparamagnetic iron oxide (SPIO)-enhanced imaging for detection of liver metastases. Twenty-three patients with 59 liver metastases underwent Gd-BOPTA-enhanced MR imaging (unenhanced, arterial, portal, equilibrium and one-hour delayed phase) using three-dimensional volumetric interpolated imaging and SPIO-enhanced T2-weighted turbo spin-echo and T2*-weighted gradient-echo sequences on a 1.5-T unit. Three observers independently interpreted the three sets of images, i.e. Gd-BOPTA-enhanced dynamic MRI (set 1), delayed phase imaging (set 2) and SPIO-enhanced MRI (set 3). Diagnostic accuracy was evaluated using the alternative-free response receiver operating chracteristic (ROC) analysis. Sensitivity and positive predictive value were also evaluated. The mean accuracy (Az values) and sensitivity of Gd-BOPTA-enhanced delayed phase imaging (0.982, 95.5%) were comparable to those of SPIO-enhanced imaging (0.984, 97.2%). In addition, Az values and sensitivities of both imaging sets were significantly higher than those of Gd-BOPTA-enhanced dynamic images (0.826, 77.4%: p<0.05). There was no significant difference in the positive predictive value among the three image sets. Gd-BOPTA-enhanced delayed phase imaging showed comparable diagnostic performance to SPIO-enhanced imaging for the detection of liver metastases, and had a better diagnostic performance than Gd-BOPTA-enhanced dynamic images.
引用
收藏
页码:220 / 228
页数:9
相关论文
共 34 条
[21]   Abdominal MR imaging with a volumetric interpolated breath-hold examination [J].
Rofsky, NM ;
Lee, VS ;
Laub, G ;
Pollack, MA ;
Krinsky, GA ;
Thomasson, D ;
Ambrosino, MM ;
Weinreb, JC .
RADIOLOGY, 1999, 212 (03) :876-884
[22]   HEPATIC MR-IMAGING WITH FERUMOXIDES - A MULTICENTER CLINICAL-TRIAL OF THE SAFETY AND EFFICACY IN THE DETECTION OF FOCAL HEPATIC-LESIONS [J].
ROS, PR ;
FREENY, PC ;
HARMS, SE ;
SELTZER, SE ;
DAVIS, PL ;
CHAN, TW ;
STILLMAN, AE ;
MUROFF, LR ;
RUNGE, VM ;
NISSENBAUM, MA ;
JACOBS, PM .
RADIOLOGY, 1995, 196 (02) :481-488
[23]  
Runge VM, 2000, J MAGN RESON IMAGING, V11, P655, DOI 10.1002/1522-2586(200006)11:6<655::AID-JMRI12>3.0.CO
[24]  
2-H
[25]  
Schima W, 1999, JMRI-J MAGN RESON IM, V10, P80, DOI 10.1002/(SICI)1522-2586(199907)10:1<80::AID-JMRI11>3.0.CO
[26]  
2-S
[27]   Detection of hepatic metastases: Ferumoxides-enhanced MR imaging versus unenhanced MR imaging and CT during arterial portography [J].
Seneterre, E ;
Taourel, P ;
Bouvier, Y ;
Pradel, J ;
VanBeers, B ;
Daures, JP ;
Pringot, J ;
Mathieu, D ;
Bruel, JM .
RADIOLOGY, 1996, 200 (03) :785-792
[28]   Comparison of unenhanced, hepatic arterial-dominant, and portal venous-dominant phase helical CT for the detection of liver metastases in women with breast carcinoma [J].
Sheafor, DH ;
Frederick, MG ;
Paulson, EK ;
Keogan, MT ;
DeLong, DM ;
Nelson, RC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :961-968
[29]  
Soyer P, 1996, EUR RADIOL, V6, P349