5.6 Tesla Fourier transform ion cyclotron resonance mass spectrometer for analysis of volatile complex mixtuues

被引:20
作者
Rodgers, RP [1 ]
White, FM [1 ]
McIntosh, DG [1 ]
Marshall, AG [1 ]
机构
[1] Florida State Univ, Natl High Magnet Field Lab, Ctr Interdisciplinary Magnet Resonance, Tallahassee, FL 32310 USA
关键词
D O I
10.1063/1.1148932
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An all-glass healed inlet coupled to a homebuilt 5.6 T Fourier transform ion cyclotron resonance mass spectrometer generates stable mass spectra from a volatile mixture for 2 h from as little as 1 mu L of injected sample. A dynamic range of similar to 500 and ultrahigh mass resolving power, m/Delta m(50%)approximate to 320 000, are shown for a series of test compounds. A raw diesel fuel sample (with hundreds of components over a wide boiling point range) mass spectrum gave similar to 500 resolved peaks over a range, 90 less than or equal to m/z<300, from which molecular formulas could be assigned from accurate (less than or equal to+/-0.8 ppm) mass measurements. (C) 1998 American Institute of Physics. [S0034-6748(98)04406-2].
引用
收藏
页码:2278 / 2284
页数:7
相关论文
共 56 条
[11]  
COMISAROW MB, 1978, ADV MASS SPECTROM, V7, P1042
[12]  
Dienes T, 1996, MASS SPECTROM REV, V15, P163, DOI 10.1002/(SICI)1098-2787(1996)15:3<163::AID-MAS2>3.0.CO
[13]  
2-G
[14]   New and efficient microextraction solid-phase extraction method for the gas chromatographic analysis of wine volatiles [J].
Ferreira, V ;
Sharman, M ;
Cacho, JF ;
Dennis, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 731 (1-2) :247-259
[15]   DETERMINATION OF UNSATURATED HYDROCARBONS BY LOW VOLTAGE MASS SPECTROMETRY [J].
FIELD, FH ;
HASTINGS, SH .
ANALYTICAL CHEMISTRY, 1956, 28 (08) :1248-1255
[16]  
Freiser BS, 1996, J MASS SPECTROM, V31, P703
[17]   TRAPPING OF POSITIVE-IONS IN ELECTRON-BEAM OF AN ION-CYCLOTRON RESONANCE SPECTROMETER [J].
FREISER, BS .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1978, 26 (01) :39-47
[18]   Stored waveform inverse Fourier transform (SWIFT) ion excitation in trapped-ion mass spectometry: Theory and applications [J].
Guan, SH ;
Marshall, AG .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1996, 157 :5-37
[19]   Resolution and chemical formula identification of aromatic hydrocarbons and aromatic compounds containing sulfur, nitrogen, or oxygen in petroleum distillates and refinery streams [J].
Guan, SH ;
Marshall, AG ;
Scheppele, SE .
ANALYTICAL CHEMISTRY, 1996, 68 (01) :46-71
[20]   Coupled subcritical water extraction with solid-phase microextraction for determining semivolatile organics in environmental solids [J].
Hageman, KJ ;
Mazeas, L ;
Grabanski, CB ;
Miller, DJ ;
Hawthorne, SB .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3892-3898