A new method based on ICBM152 head surface for probe placement in multichannel fNIRS

被引:92
作者
Cutini, Simone [1 ,2 ]
Scatturin, Pietro [2 ]
Zorzi, Marco [1 ]
机构
[1] Univ Padua, Dept Gen Psychol, I-35131 Padua, Italy
[2] Univ Padua, Dept Dev Psychol & Socializat, I-35131 Padua, Italy
关键词
NEAR-INFRARED SPECTROSCOPY; TRANSCRANIAL FUNCTIONAL BRAIN; SPATIAL REGISTRATION; ELECTRODE PLACEMENT; MNI SPACE; SYSTEM; MRI; NEURONAVIGATION; LOCALIZATION; ACTIVATION;
D O I
10.1016/j.neuroimage.2010.09.030
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We propose a new probe placement method for multichannel functional Near Infrared Spectroscopy (fNIRS) based on the ICBM152 template, the most commonly used reference brain for neuroimaging. Our method is based on the use of a physical model of the ICBM152 head surface as reference scalp and its validity is supported by previous investigations of cranio-cerebral correlation. The method, intended for fNIRS group studies. dispenses with the use of individual MRI scan and digitizing procedure for each participant. The present approach offers a fast, simple, reproducible and straightforward method to place the probes on the head surface according to the MNI coordinates of the regions of interest with an average measurement error similar to those of previous methods. This ensures that fNIRS results can be readily compared within the neuroimaging community, both across studies and techniques. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:919 / 927
页数:9
相关论文
共 35 条
[21]   A probabilistic atlas and reference system for the human brain: International Consortium for Brain Mapping (ICBM) [J].
Mazziotta, J ;
Toga, A ;
Evans, A ;
Fox, P ;
Lancaster, J ;
Zilles, K ;
Woods, R ;
Paus, T ;
Simpson, G ;
Pike, B ;
Holmes, C ;
Collins, L ;
Thompson, P ;
MacDonald, D ;
Iacoboni, M ;
Schormann, T ;
Amunts, K ;
Palomero-Gallagher, N ;
Geyer, S ;
Parsons, L ;
Narr, K ;
Kabani, N ;
Le Goualher, G ;
Boomsma, D ;
Cannon, T ;
Kawashima, R ;
Mazoyer, B .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 2001, 356 (1412) :1293-1322
[22]  
Mazziotta J. C., 2000, BRAIN MAPPING SYSTEM, P141
[23]   THE VALUE OF CLOSELY SPACED SCALP ELECTRODES IN THE LOCALIZATION OF EPILEPTIFORM FOCI - A STUDY OF 26 PATIENTS WITH COMPLEX PARTIAL SEIZURES [J].
MORRIS, HH ;
LUDERS, H ;
LESSER, RP ;
DINNER, DS ;
KLEM, GH .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1986, 63 (02) :107-111
[24]  
Okamoto M, 2005, NEUROIMAGE, V26, P18, DOI 10.1016/j.neuroimage.2005.01.018
[25]   Three-dimensional probabilistic anatomical cranio-cerebral correlation via the international 10-20 system oriented for transcranial functional brain mapping [J].
Okamoto, M ;
Dan, H ;
Sakamoto, K ;
Takeo, K ;
Shimizu, K ;
Kohno, S ;
Oda, I ;
Isobe, S ;
Suzuki, T ;
Kohyama, K ;
Dan, I .
NEUROIMAGE, 2004, 21 (01) :99-111
[26]   ABSORPTION-SPECTROSCOPY IN TISSUE-SIMULATING MATERIALS - A THEORETICAL AND EXPERIMENTAL-STUDY OF PHOTON PATHS [J].
PATTERSON, MS ;
ANDERSSONENGELS, S ;
WILSON, BC ;
OSEI, EK .
APPLIED OPTICS, 1995, 34 (01) :22-30
[27]   Neuronavigation accuracy dependence on CT and MR imaging parameters: a phantom-based study [J].
Poggi, S ;
Pallotta, S ;
Russo, S ;
Gallina, P ;
Torresin, A ;
Bucciolini, M .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (14) :2199-2216
[28]   Virtual pointer projection of the central sulcus to the outside of the skull using frameless neuronavigation -: Accuracy and applications [J].
Reinges, MHT ;
Krings, T ;
Nguyen, HH ;
Küker, W ;
Spetzger, U ;
Rohde, V ;
Hütter, BO ;
Thron, A ;
Gilsbach, JM .
ACTA NEUROCHIRURGICA, 2000, 142 (12) :1385-1390
[29]   Altered frontal brain oxygenation patients with unaffected verbal in fluency performance [J].
Schecklmann, Martin ;
Ehlis, Ann-Christine ;
Plichta, Michael M. ;
Boutter, Heike K. ;
Metzger, Florian G. ;
Fallgatter, Andreas J. .
PSYCHIATRY RESEARCH-NEUROIMAGING, 2007, 156 (02) :129-138
[30]   Spatial registration of multichannel multi-subject fNIRS data to MNI space without MRI [J].
Singh, AK ;
Okamoto, M ;
Dan, H ;
Jurcak, V ;
Dan, I .
NEUROIMAGE, 2005, 27 (04) :842-851