Immobilization of uricase upon polypyrrole-ferrocenium film

被引:22
作者
Cete, Servet [1 ]
Yasar, Ahmet [1 ]
Arslan, Fatma [1 ]
机构
[1] Gazi Univ, Fac Arts & Sci, Dept Chem, Ankara, Turkey
来源
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY | 2007年 / 35卷 / 06期
关键词
glutaraldehyde; immobilization; polypyrrole; uricase;
D O I
10.1080/10731190701378634
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
In this study, uricase was immobilized by a glutaraldehyde/gelatine crosslinking procedure onto polypyrrole film. The K, value for immobilized enzyme 0.44mM was much higher than that of the free enzyme 0.39mM. V-max values were 8.4 x 10(-2) mM/dak and 7.1 x 10(-2) mM/dak for free and immobilized enzyme, respectively. The optimal pH values for free and immobilized enzymes were 8.5 and 8.0, respectively. The optimum temperature for both free and immobilized uricase was 35 degrees C and 55 degrees C. The enzyme activity after storage for 7 weeks was found to be 42% and 49% of the initial activity values for free and immobilized enzymes, respectively. The amperometric current obtained after 30 measurements at a constant uric acid concentration of 5.0 x 10(-5) M was found to be 77.7% of initial activity.
引用
收藏
页码:607 / 620
页数:14
相关论文
共 38 条
[1]   A biosensor based on urate oxidase-peroxidase coupled enzyme system for uric acid determination in urine [J].
Akyilmaz, E ;
Sezgintürk, MK ;
Dinçkaya, E .
TALANTA, 2003, 61 (02) :73-79
[2]   PURIFICATION AND MOLECULAR-PROPERTIES OF URATE OXIDASE FROM CHLAMYDOMONAS-REINHARDTII [J].
ALAMILLO, JM ;
CARDENAS, J ;
PINEDA, M .
BIOCHIMICA ET BIOPHYSICA ACTA, 1991, 1076 (02) :203-208
[3]   Preparation of Pt/polypyrrole-ferrocene hydrogen peroxide sensitive electrode for the use as a biosensor [J].
Arslan, F ;
Yasar, A ;
Kiliç, E .
RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2006, 42 (02) :137-140
[4]  
BARTLETT PN, 1993, J ELECTROANAL CHEM, V362, P1
[5]   ELECTROCONDUCTING CONJUGATED POLYMERS - NEW SENSITIVE MATRICES TO BUILD UP CHEMICAL OR ELECTROCHEMICAL SENSORS - A REVIEW [J].
BIDAN, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) :45-56
[6]  
CASS AEG, 1990, BIOSENSORS
[7]   Conductometric uric acid and urea biosensor prepared from electroconductive polyaniline-poly(n-butyl methacrylate) composites [J].
Castillo-Ortega, MM ;
Rodriguez, DE ;
Encinas, JC ;
Plascencia, M ;
Méndez-Velarde, FA ;
Olayo, R .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (1-2) :19-25
[8]   An amperometric biosensor for uric acid determination prepared from uricase immobilized in polypyrrole film [J].
Cete, Servet ;
Yasar, Ahmet ;
Arslan, Fatma .
ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2006, 34 (03) :367-380
[9]   Mediated biosensors [J].
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :441-456
[10]   A comparative physical study of two different hydrophilic synthetic latex matrices for the construction of a glucose biosensor [J].
Cosnier, S ;
Szunerits, S ;
Marks, RS ;
Novoa, A ;
Puech, L ;
Perez, E ;
Rico-Lattes, I .
TALANTA, 2001, 55 (05) :889-897