Accuracy of templates for navigated implantation made by rapid prototyping with DICOM datasets of cone beam computer tomography (CBCT)

被引:11
作者
Weitz, Jochen [1 ]
Deppe, Herbert [1 ]
Stopp, Sebastian [2 ]
Lueth, Tim [2 ]
Mueller, Steffen [1 ]
Hohlweg-Majert, Bettina [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Oral & Craniomaxillofacial Surg, D-8000 Munich, Germany
[2] Tech Univ Munich, Dept Microtechnol & Med Device Technol MIMED, D-8000 Munich, Germany
关键词
CBCT; DICOM; Dental implant; Rapid prototyping; CLINICAL-APPLICATION; SURGICAL TEMPLATE; FIXED PROSTHESIS; ORAL IMPLANTS; CT; PLACEMENT; IMAGES; DOSIMETRY; MACHINE; DEVICES;
D O I
10.1007/s00784-010-0468-9
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
The aim of this study is to evaluate the accuracy of a surgical template-aided implant placement produced by rapid prototyping using a DICOM dataset from cone beam computer tomography (CBCT). On the basis of CBCT scans (SironaA (R) Galileos), a total of ten models were produced using a rapid-prototyping three-dimensional printer. On the same patients, impressions were performed to compare fitting accuracy of both methods. From the models made by impression, templates were produced and accuracy was compared and analyzed with the rapid-prototyping model. Whereas templates made by conventional procedure had an excellent accuracy, the fitting accuracy of those produced by DICOM datasets was not sufficient. Deviations ranged between 2.0 and 3.5 mm, after modification of models between 1.4 and 3.1 mm. The findings of this study suggest that the accuracy of the low-dose Sirona GalileosA (R) DICOM dataset seems to show a high deviation, which is not useable for accurate surgical transfer for example in implant surgery.
引用
收藏
页码:1001 / 1006
页数:6
相关论文
共 33 条
[1]
Evaluation of transversal slice imaging in the diagnosis of tooth displacement with special consideration of the upper canines; [Evaluierung transversaler Schichtaufnahmen zur Diagnostik von Zahnverlagerungen unter besonderer Berücksichtigung oberer Eckzähne] [J].
Broer N. ;
Fuhrmann A. ;
Bremert S. ;
Schulze D. ;
Kahl-Nieke B. .
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2005, 66 (2) :94-109
[2]
Comparative study of jaws with multislice computed tomography and cone-beam computed tomography [J].
Carrafiello, G. ;
Dizonno, M. ;
Colli, V. ;
Strocchi, S. ;
Taubert, S. Pozzi ;
Leonardi, A. ;
Giorgianni, A. ;
Barresi, M. ;
Macchi, A. ;
Bracchi, E. ;
Conte, L. ;
Fugazzola, C. .
RADIOLOGIA MEDICA, 2010, 115 (04) :600-611
[3]
The management of a severely resorbed edentulous maxilla using a bone graft and a CAD/CAM-guided immediately loaded definitive implant prosthesis: A clinical report [J].
Cheng, Ansgar C. ;
Tee-Khin, Neo ;
Siew-Luen, Chan ;
Lee, Helena ;
Wee, Alvin G. .
JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02) :85-90
[4]
Di Giacomo GAP, 2005, J PERIODONTOL, V76, P503
[5]
Advances in three dimensional printing - state of the art and future perspectives [J].
Dimitrov, D. ;
Schreve, K. ;
de Beer, N. .
RAPID PROTOTYPING JOURNAL, 2006, 12 (03) :136-147
[6]
Investigating the achievable accuracy of three dimensional printing [J].
Dimitrov, D ;
van Wijck, W ;
Schreve, K ;
de Beer, N .
RAPID PROTOTYPING JOURNAL, 2006, 12 (01) :42-52
[7]
Accuracy of a newly developed integrated system for dental implant planning [J].
Dreiseidler, Timo ;
Neugebauer, Joerg ;
Ritter, Lutz ;
Lingohr, Thea ;
Rothamel, Daniel ;
Mischkowski, Robert A. ;
Zoeller, Joachim E. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (11) :1191-1199
[8]
Computer-aided navigation in dental implantology: 7 years of clinical experience [J].
Ewers, R ;
Schicho, K ;
Truppe, M ;
Seemann, R .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 62 (03) :329-334
[9]
Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine - An in vitro study [J].
Fortin, T ;
Champleboux, G ;
Bianchi, S ;
Buatois, H ;
Coudert, FL .
CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (06) :651-656
[10]
Gebhardt A, 2000, IND RAPID PROTOTYPIN