Accuracy of a newly developed integrated system for dental implant planning

被引:74
作者
Dreiseidler, Timo [1 ]
Neugebauer, Joerg [1 ]
Ritter, Lutz [1 ]
Lingohr, Thea [1 ]
Rothamel, Daniel [1 ]
Mischkowski, Robert A. [1 ]
Zoeller, Joachim E. [1 ]
机构
[1] Univ Cologne, Dept Craniomaxillofacial & Plast Surg, D-50924 Cologne, Germany
关键词
computer-aided surgery (CAS); cone-beam imaging (CBCT); dental implantology; surgical templates; drill templates; surgical guides; CONE-BEAM CT; DIGITAL VOLUME TOMOGRAPHY; MAXILLOFACIAL-RADIOLOGY; SURGICAL GUIDE; IN-VITRO; PLACEMENT; SURGERY; DEVICE; NAVIGATION; DENTISTRY;
D O I
10.1111/j.1600-0501.2009.01764.x
中图分类号
R78 [口腔科学];
学科分类号
100302 [口腔临床医学];
摘要
Objectives To evaluate the accuracy of the first integrated system for cone-beam CT (CBCT) imaging, dental implant planning and surgical template-aided implant placement. Materials and methods On the basis of CBCT scans, a total of 54 implant positions were planned for 10 partially edentulous anatomical patient-equivalent models. Surgical guides were ordered from the manufacturer (SICAT). Two different types of guidance were assessed: for assessment of the SICAT system inherent accuracy vendor's titanium sleeves of 2 mm internal diameter and 5 mm length were utilized for pilot drills. The guide sleeves of the NobelGuide system were implemented for fully guided surgery and implant insertion. Deviations perpendicular to the implant axes at the crestal and apical end, as well as the angle deviations between the virtual planning data and the surgical results, were measured utilizing a follow-up CBCT investigation and referential marker-based registration. Results The SICAT system inherent mean deviation rates for the drilled pilot osteotomies were determined to be smaller than 500 mu m even at the apical end. Mean angle deviations of 1.18 degrees were determined. Utilizing the NobelGuide sleeve-in-sleeve system for fully guided implant insertion in combination with the investigated template technology enabled to insert dental implants with the same accuracy. Crestal deviations, in general, were significantly lower than the apical deviations. Conclusion Although hardly comparable due to different study designs and measurement strategies, the investigated SICAT system's inherent accuracy corresponds to the most favourable results for computer-aided surgery systems published so far. In combination with the NobelGuide surgical set for fully guided insertion, the same accuracy level could be maintained for implant positioning. To cite this article:Dreiseidler T, Neugebauer J, Ritter L, Lingohr T, Rothamel D, Mischkowski RA, Zoller JE. Accuracy of a newly developed integrated system for dental implant planning.Clin. Oral Impl. Res. 20, 2009; 1191-1199.doi: 10.1111/j.1600-0501.2009.01764.x.
引用
收藏
页码:1191 / 1199
页数:9
相关论文
共 28 条
[1]
In-vitro assessment of a registration protocol for image guided implant dentistry [J].
Birkfellner, W ;
Solar, P ;
Gahleitner, A ;
Huber, K ;
Kainberger, F ;
Kettenbach, J ;
Homolka, P ;
Diemling, M ;
Watzek, G ;
Bergmann, H .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (01) :69-78
[2]
Evaluation of transversal slice imaging in the diagnosis of tooth displacement with special consideration of the upper canines; [Evaluierung transversaler Schichtaufnahmen zur Diagnostik von Zahnverlagerungen unter besonderer Berücksichtigung oberer Eckzähne] [J].
Broer N. ;
Fuhrmann A. ;
Bremert S. ;
Schulze D. ;
Kahl-Nieke B. .
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2005, 66 (2) :94-109
[3]
Radiation dose in dental radiology [J].
Cohnen, M ;
Kemper, J ;
Möbes, O ;
Pawelzik, J ;
Mödder, U .
EUROPEAN RADIOLOGY, 2002, 12 (03) :634-637
[4]
ROLE OF DIAGNOSTIC-IMAGING IN EVALUATION OF THE DENTAL IMPLANT PATIENT [J].
DELBALSO, AM ;
GREINER, FG ;
LICATA, M .
RADIOGRAPHICS, 1994, 14 (04) :699-719
[5]
Dreiseidler T, 2009, INT J ORAL MAX IMPL, V24, P216
[6]
Computer-aided navigation in dental implantology: 7 years of clinical experience [J].
Ewers, R ;
Schicho, K ;
Truppe, M ;
Seemann, R .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 62 (03) :329-334
[7]
Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine - An in vitro study [J].
Fortin, T ;
Champleboux, G ;
Bianchi, S ;
Buatois, H ;
Coudert, FL .
CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (06) :651-656
[8]
Fortin Thomas, 2004, Clin Implant Dent Relat Res, V6, P111, DOI 10.1111/j.1708-8208.2004.tb00033.x
[9]
A new low-dose CT examination compared with standard-dose CT in the diagnosis of acute sinusitis [J].
Hagtvedt, T ;
Aalokken, TM ;
Notthellen, J ;
Kolbenstvedt, A .
EUROPEAN RADIOLOGY, 2003, 13 (05) :976-980
[10]
Comparative examination of the accuracy of a mechanical and an optical system in CT and MRT based instrument navigation [J].
Hassfeld, S ;
Mühling, J .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 29 (06) :400-407