Direct loop-mediated isothermal amplification from Plasmodium chabaudi infected blood samples: Inability to discriminate genomic and cDNA sequences

被引:11
作者
Ebbinghaus, Petra [1 ]
von Samson-Himmelstjerna, Georg [1 ]
Kruecken, Juergen [1 ]
机构
[1] Free Univ Berlin, Inst Parasitol & Vet Med, Berlin, Germany
关键词
Loop-mediated isothermal amplification; Plasmodium chabaudi; Gene expression; Direct amplification; RT-control; ELECTROCHEMICAL DNA CHIP; REVERSE-TRANSCRIPTION; RAPID DETECTION; LAMP METHOD; DIAGNOSIS; MALARIA; PARASITES; VIRUS; ASSAY; KNOWLESI;
D O I
10.1016/j.exppara.2012.02.024
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
Loop-mediated isothermal amplification (LAMP) has been increasingly used for diagnosis and quantification of pathogens. Since the Bst DNA polymerase used in this assay is highly resistant to PCR inhibitors present in blood, direct analysis of blood samples without DNA or RNA extraction is possible. Indeed, the presence of Plasmodium chabaudi specific nucleic acids was easily detectable using primer sets for P. chabaudi 18S rRNA and the cir 1 mRNA. Despite the fact that primers for cir 1, glyceraldehyde 3-phosphate dehydrogenase (GAPDH) and actin II mRNAs were used that spanned an intron, selective amplification of mRNA in the presence of contaminating genomic DNA was not possible. Optimization of the reaction temperature could only improve discrimination when low complexity templates (target sequences cloned in a plasmid vector) were used. Placing different LAMP primers across intron exon boundaries did not prevent amplification in the absence of reverse transcriptase. Probably due to the high A + T content and low number of introns only a very limited number of possible primer sets spanning introns could be identified in the target genes and no reaction conditions could be established that would allow quantification of RNA levels in the presence of DNA directly from blood samples. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:40 / 44
页数:5
相关论文
共 38 条
[11]   Using Detergent to Enhance Detection Sensitivity of African Trypanosomes in Human CSF and Blood by Loop-Mediated Isothermal Amplification (LAMP) [J].
Grab, Dennis J. ;
Nikolskaia, Olga V. ;
Inoue, Noboru ;
Thekisoe, Oriel M. M. ;
Morrison, Liam J. ;
Gibson, Wendy ;
Dumler, J. Stephen .
PLOS NEGLECTED TROPICAL DISEASES, 2011, 5 (08)
[12]   A comprehensive survey of the Plasmodium life cycle by genomic, transcriptomic, and proteomic analyses [J].
Hall, N ;
Karras, M ;
Raine, JD ;
Carlton, JM ;
Kooij, TWA ;
Berriman, M ;
Florens, L ;
Janssen, CS ;
Pain, A ;
Christophides, GK ;
James, K ;
Rutherford, K ;
Harris, B ;
Harris, D ;
Churcher, C ;
Quail, MA ;
Ormond, D ;
Doggett, J ;
Trueman, HE ;
Mendoza, J ;
Bidwell, SL ;
Rajandream, MA ;
Carucci, DJ ;
Yates, JR ;
Kafatos, FC ;
Janse, CJ ;
Barrell, B ;
Turner, CMR ;
Waters, AP ;
Sinden, RE .
SCIENCE, 2005, 307 (5706) :82-86
[13]   Discriminating between varicella-zoster virus vaccine and wild-type strains by loop-mediated isothermal amplification [J].
Higashimoto, Yuki ;
Ihira, Masaru ;
Ohta, Akane ;
Inoue, Shigeki ;
Usui, Chie ;
Asano, Yoshizo ;
Yoshikawa, Tetsushi .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (08) :2665-2670
[14]   Development of a multiplex loop-mediated isothermal amplification (mLAMP) method for the simultaneous detection of bovine Babesia parasites [J].
Iseki, Hiroshi ;
Alhassan, Andy ;
Ohta, Naomi ;
Thekisoe, Oriel M. M. ;
Yokoyama, Naoaki ;
Inoue, Noboru ;
Nambota, Andrew ;
Yasuda, Jun ;
Igarashi, Ikuo .
JOURNAL OF MICROBIOLOGICAL METHODS, 2007, 71 (03) :281-287
[15]   Evaluation of a Loop-Mediated Isothermal Amplification Method as a Tool for Diagnosis of Infection by the Zoonotic Simian Malaria Parasite Plasmodium knowlesi [J].
Iseki, Hiroshi ;
Kawai, Satoru ;
Takahashi, Nobuyuki ;
Hirai, Makoto ;
Tanabe, Kazuyuki ;
Yokoyama, Naoaki ;
Igarashi, Ikuo .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (07) :2509-2514
[16]   Deletion of LTβR augments male susceptibility to Plasmodium chabaudi [J].
Krücken, J ;
Braun, JV ;
Dkhil, MA ;
Grunwald, A ;
Wunderlich, F .
PARASITE IMMUNOLOGY, 2005, 27 (06) :205-212
[17]   Augmented particle trapping and attenuated inflammation in the liver by protective vaccination against Plasmodium chabaudi malaria [J].
Kruecken, Juergen ;
Delic, Denis ;
Pauen, Heike ;
Wojtalla, Anna ;
El-Khadragy, Manal ;
Dkhil, Mohamed A. ;
Mossmann, Horst ;
Wunderlich, Frank .
MALARIA JOURNAL, 2009, 8
[18]   Prevalence of Trypanosoma sp in cattle from Tanzania estimated by conventional PCR and loop-mediated isothermal amplification (LAMP) [J].
Laohasinnarong, Dusit ;
Thekisoe, Oriel M. M. ;
Malele, Imna ;
Namangala, Boniface ;
Ishii, Akihiro ;
Goto, Yasuyuki ;
Kawazu, Shin-ichiro ;
Sugimoto, Chihiro ;
Inoue, Noboru .
PARASITOLOGY RESEARCH, 2011, 109 (06) :1735-1739
[19]   Specific, Sensitive, and Rapid Diagnosis of Active Toxoplasmosis by a Loop-Mediated Isothermal Amplification Method Using Blood Samples from Patients [J].
Lau, Yee Ling ;
Meganathan, Puviarasi ;
Sonaimuthu, Parthasarathy ;
Thiruvengadam, Girija ;
Nissapatorn, Veeranoot ;
Chen, Yeng .
JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (10) :3698-3702
[20]   Specific, sensitive and rapid detection of human plasmodium knowlesi infection by loop-mediated isothermal amplification (LAMP) in blood samples [J].
Lau, Yee-Ling ;
Fong, Mun-Yik ;
Mahmud, Rohela ;
Chang, Phooi-Yee ;
Palaeya, Vanitha ;
Cheong, Fei-Wen ;
Chin, Lit-Chein ;
Anthony, Claudia N. ;
Al-Mekhlafi, Abdulsalam M. ;
Chen, Yeng .
MALARIA JOURNAL, 2011, 10