A new small coil-volume CCC instrument for direct interfacing with MS

被引:27
作者
Janaway, L
Hawes, D
Ignatova, S
Wood, P
Sutherland, IA [1 ]
机构
[1] Brunel Univ, Brunel Inst Bioengn, Uxbridge UB8 3PH, Middx, England
[2] Russian Acad Sci, Vernadsky Inst Geochem & Analyt Chem, Moscow, Russia
关键词
small volume CCC machine; J-type coil planet centrifuge; mass spectrometry coupling;
D O I
10.1081/JLC-120021254
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
One of the major factors restricting the use of CCC as an analytical tool is the speed at which a separation may be conducted. This paper describes the phased development of a new low volume capacity Milli-CCC device, which is as rapid as HPLC, achieving high resolutions in minutes as opposed to hours, with the capability of linking with a mass spectrometer (CCC/MS). The Milli-CCC J-type apparatus has gears enclosed in a lubricated case to minimize noise. Its volume with one coil mounted in a cantilever style is 4.6 mL with 2.5 m of 0.76 nun bore tubing. It can rotate at a maximum speed of 2 100 rpm. Stationary phase retention factor higher than 60% could be obtained with 1500 rpm and 1 mL/min producing separation of compounds with K-D distribution coefficient of 1 in less than 5 min. The connection to MS was straightforward.
引用
收藏
页码:1345 / 1354
页数:10
相关论文
共 14 条
[1]   EFFICIENCY AND RESOLUTION IN COUNTERCURRENT CHROMATOGRAPHY [J].
BOUSQUET, O ;
FOUCAULT, AP ;
LEGOFFIC, F .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1991, 14 (18) :3343-3363
[2]   ANALYTICAL HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY WITH A COIL PLANET CENTRIFUGE [J].
ITO, Y ;
LEE, YW .
JOURNAL OF CHROMATOGRAPHY, 1987, 391 (01) :290-295
[3]   Separation and characterisation of five polar herbicides using countercurrent chromatography with detection by negative ion electrospray ionisation mass spectrometry [J].
Kidwell, H ;
Jones, JJ ;
Games, DE .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (14) :1181-1186
[4]   LUNG RESPONSE TO ULTRAFINE KEVLAR ARAMID SYNTHETIC FIBRILS FOLLOWING 2-YEAR INHALATION EXPOSURE IN RATS [J].
LEE, KP ;
KELLY, DP ;
ONEAL, FO ;
STADLER, JC ;
KENNEDY, GL .
FUNDAMENTAL AND APPLIED TOXICOLOGY, 1988, 11 (01) :1-20
[5]  
Mandava N.B., 1988, COUNTER CURRENT CHRO, V44, P79
[6]   EVALUATION OF ANALYTICAL COUNTERCURRENT CHROMATOGRAPHS - HIGH-SPEED COUNTERCURRENT CHROMATOGRAPH-4000 VS ANALYTICAL TOROIDAL COIL CENTRIFUGE [J].
OKA, H ;
IKAI, Y ;
KAWAMURA, N ;
YAMADA, M ;
HARADA, KI ;
SUZUKI, M ;
CHOU, FE ;
LEE, YW ;
ITO, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (12) :2309-2328
[7]   DIRECT INTERFACING OF HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY TO FRIT ELECTRON IONIZATION, CHEMICAL IONIZATION, AND FAST-ATOM-BOMBARDMENT MASS-SPECTROMETRY [J].
OKA, H ;
IKAI, Y ;
KAWAMURA, N ;
HAYAKAWA, J ;
HARADA, K ;
MURATA, H ;
SUZUKI, M ;
ITO, Y .
ANALYTICAL CHEMISTRY, 1991, 63 (24) :2861-2865
[8]   Countercurrent chromatography (CCC) and its versatile application as an industrial purification & production process [J].
Sutherland, IA ;
Brown, L ;
Forbes, S ;
Games, G ;
Hawes, D ;
Hostettmann, K ;
McKerrell, EH ;
Marston, A ;
Wheatley, D ;
Wood, P .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (03) :279-298
[9]   Modelling CCC using an eluting countercurrent distribution model [J].
Sutherland, IA ;
de Folter, J ;
Wood, P .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (9-10) :1449-1474
[10]   Resolution in CCC: The effect of operating conditions and phase system properties on scale-up [J].
Sutherland, IA ;
Hawes, D ;
van den Heuvel, R ;
Janaway, L ;
Tinnion, E .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (9-10) :1475-1491