Chemiluminescence nitrogen detection in ion chromatography for the determination of nitrogen-containing anions

被引:15
作者
Lucy, CA [1 ]
Harrison, CR [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
关键词
chemiluminescence nitrogen detection; detection; LC; inorganic anions;
D O I
10.1016/S0021-9673(01)00711-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chemiluminescence nitrogen detection (CLND) provides equimolar response for nitrogen-containing ions such as nitrate, nitrite, cyanide, ammonium and tetradecyltrimethylammonium. Only azide yields a lower response. Nitrite, azide and nitrate are separated on a Dionex AS11 column using 5 mM NaOH as eluent with a 3 muM (1 ng N) limit of detection. Matrices, such as 1:10 diluted seawater, do not degrade these detection limits. CLND also provides equally sensitive (Limit of detection 3 muM, 78 ppb) detection of weak acids such, as cyanide, which yield poor sensitivity with suppressed conductivity detection. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 22 条
[1]  
BOEHM KA, 1995, J AOAC INT, V78, P301
[2]  
BORNY JF, 1998, ANTEK 8060 MANUAL
[3]   Enhanced conductometric detection of cyanide in suppressed ion chromatography [J].
Caliamanis, A ;
McCormick, MJ ;
Carpenter, PD .
JOURNAL OF CHROMATOGRAPHY A, 2000, 884 (1-2) :75-80
[4]  
CHANG R, 1991, CHEMISTRY, P377
[5]   A study of the thermal decomposition of azidoacetone by photoelectron and matrix isolation spectroscopy [J].
Dyke, JM ;
Groves, AP ;
Morris, A ;
Ogden, JS ;
Catarino, MI ;
Dias, AA ;
Oliveira, AMS ;
Costa, ML ;
Barros, MT ;
Cabral, MH ;
Moutinho, AMC .
JOURNAL OF PHYSICAL CHEMISTRY A, 1999, 103 (41) :8239-8245
[6]   Chemiluminescent nitrogen detection for HPLC: An important new tool in organic analytical chemistry [J].
Fitch, WL ;
Szardenings, AK ;
Fujinari, EM .
TETRAHEDRON LETTERS, 1997, 38 (10) :1689-1692
[7]   Determination of molecular-mass distribution of food-grade protein hydrolyzates by size-exclusion chromatography and chemiluminescent nitrogen detection [J].
Fujinari, EM ;
Manes, JD .
JOURNAL OF CHROMATOGRAPHY A, 1997, 763 (1-2) :323-329
[8]   NITROGEN-SPECIFIC LIQUID-CHROMATOGRAPHY DETECTOR BASED ON CHEMILUMINESCENCE - APPLICATION TO THE ANALYSIS OF AMMONIUM NITROGEN IN WASTE-WATER [J].
FUJINARI, EM ;
COURTHAUDON, LO .
JOURNAL OF CHROMATOGRAPHY, 1992, 592 (1-2) :209-214
[9]   POSTCOLUMN LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF CYANIDE WITH FLUOROMETRIC DETECTION [J].
GAMOH, K ;
IMAMICHI, S .
ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) :255-259
[10]   MECHANISM AND MODELING OF HYDROGEN-CYANIDE OXIDATION IN A FLOW REACTOR [J].
GLARBORG, P ;
MILLER, JA .
COMBUSTION AND FLAME, 1994, 99 (3-4) :475-483