Analytical application of poly{methyl[3-(2-hydroxy-3,4-difluoro)phenyl] propyl siloxane} as a QCM coating for DMMP detection

被引:55
作者
He, Wei [1 ]
Liu, Zhongxiang [1 ]
Du, Xiaosong [1 ]
Jiang, Yadong [1 ]
Xiao, Dan [2 ]
机构
[1] Univ Elect Sci & Technol China, State Key Lab Elect Thin Films & Integrated Devic, Chengdu 610054, Peoples R China
[2] Sichuan Univ, Coll Chem, Chengdu 610065, Peoples R China
基金
中国国家自然科学基金;
关键词
poly{methyl[3-(2-hydroxy-3,4-difluoro)phenyl]propyl siloxane}; DMMP; QCM; selectivity;
D O I
10.1016/j.talanta.2008.04.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new material-poly{methyl[3-(2-hydroxy-3,4-difluoro)phenyl]propyl siloxane}(PMDFPS) sensitive to toxic organophosphate vapor was synthesized with 2,3-difluorophenol, allyl bromide and poly (methyl hydrosiloxane) as raw materials, via O-alkylation, Claisen rearrange reaction and hydrosilylation reaction. This novel material was then coated on a quartz crystal microbalance (QCM) to investigate its gas sensitive properties to the nerve agent simulant dimethyl methylphosphonate (DMMP) vapor, as well as known interfering vapors. When tested with competing vapors, the sensor was more than 10 times sensitive to DMMP than to other interfering vapors. Thus, high selectivity of poly{methyl[3-(2-hydroxy-3,4-difluoro)phenyl]propyl siloxane} to DMMP was demonstrated. The poly{methyl[3-(2-hydroxy-3,4-difluoro)phenyl]propyl siloxane}-QCM sensor responded linearly to DMMP vapor with a slope of 14 Hz/ppm in the 1-50 ppm range with a detection limit of 0.21 ppm (S/N = 3). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:698 / 702
页数:5
相关论文
共 22 条
[1]   POLYMER SORBENTS FOR PHOSPHORUS ESTERS .2. HYDROGEN-BOND DRIVEN SORPTION IN FLUORO-CARBINOL SUBSTITUTED POLYSTYRENE [J].
BARLOW, JW ;
CASSIDY, PE ;
LLOYD, DR ;
YOU, CJ ;
CHANG, Y ;
WONG, PC ;
NORIYAN, J .
POLYMER ENGINEERING AND SCIENCE, 1987, 27 (10) :703-715
[2]   ATOMIC-EMISSION DETECTION FOR THE QUANTITATION OF TRIMETHYLSILYL DERIVATIVES OF CHEMICAL-WARFARE-AGENT RELATED-COMPOUNDS IN ENVIRONMENTAL-SAMPLES [J].
CREASY, WR ;
RODRIGUEZ, AA ;
STUFF, JR ;
WARREN, RW .
JOURNAL OF CHROMATOGRAPHY A, 1995, 709 (02) :333-344
[3]   Capillary gas chromatographic analysis of nerve agents using large volume injections [J].
DegenhardtLangelaan, CEAM ;
Kientz, CE .
JOURNAL OF CHROMATOGRAPHY A, 1996, 723 (01) :210-214
[4]   Environmental and forensic applications of field-portable GC-MS: An overview [J].
Eckenrode, BA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2001, 12 (06) :683-693
[5]   SOLUBILITY INTERACTIONS AND THE DESIGN OF CHEMICALLY SELECTIVE SORBENT COATINGS FOR CHEMICAL SENSORS AND ARRAYS [J].
GRATE, JW ;
ABRAHAM, MH .
SENSORS AND ACTUATORS B-CHEMICAL, 1991, 3 (02) :85-111
[6]   Hydrogen bond acidic polymers for surface acoustic wave vapor sensors and arrays [J].
Grate, JW ;
Patrash, SJ ;
Kaganove, SN ;
Wise, BM .
ANALYTICAL CHEMISTRY, 1999, 71 (05) :1033-1040
[7]   Hybrid organic/inorganic copolymers with strongly hydrogen-bond acidic properties for acoustic wave and optical sensors [J].
Grate, JW ;
Kaganove, SN ;
Patrash, SJ ;
Craig, R ;
Bliss, M .
CHEMISTRY OF MATERIALS, 1997, 9 (05) :1201-1207
[8]   Application of microcolumn liquid chromatography and capillary electrophoresis with flame photometric detection for the screening of degradation products of chemical warfare agents in water and soil [J].
Hooijschuur, EWJ ;
Kientz, CE ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2001, 928 (02) :187-199
[9]   Rational materials design of sorbent coatings for explosives: applications with chemical sensors [J].
Houser, EJ ;
Mlsna, TE ;
Nguyen, VK ;
Chung, R ;
Mowery, RL ;
McGill, RA .
TALANTA, 2001, 54 (03) :469-485
[10]   Chromatography and mass spectrometry of chemical warfare agents, toxins and related compounds: state of the art and future prospects [J].
Kientz, CE .