Less invasive determination of cardiac output from the arterial pressure by aortic diameter-calibrated pulse contour

被引:55
作者
de Vaal, JB
de Wilde, RBP
van den Berg, PCM
Schreuder, JJ
Jansen, JRC
机构
[1] Leiden Univ, Med Ctr, Dept Intens Care H4Q, NL-2300 RC Leiden, Netherlands
[2] Hosp San Raffaele, Dept Cardiac Surg, I-20132 Milan, Italy
关键词
arterial pressure; arteries; aortic diameter; heart; cardiac output; measurement techniques; thermodilution; model; computer simulation;
D O I
10.1093/bja/aei189
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Cardiac output by modelflow pulse contour method can be monitored quantitatively and continuously only after an initial calibration, to adapt the model to an individual patient. The modelflow. method computes beat-to-beat cardiac output (COmf) from the radial artery pressure, by simulating a three-element model of aortic impedance with post-mortem data from human aortas. Methods. In our improved version of modelflow (COmfc) we adapted this model to a real time measure of the aortic cross-sectional area (CSA) of the descending aorta just above the diaphragm, measured by a new transoesophageal echo device (HemoSonic 100). COmf and COmfc were compared with thermodilution cardiac output (COtd) in 24 patients in the intensive care unit. Each thermodilution value was the mean of four measurements equally spread over the ventilatory cycle. Results. Least squares regression of COtd vs COmf gave y = 1.09x[95% confidence interval (CI) 0.96-1.22], R-2=0. 15, and of COtd vs COmfc resulted in y= 1.02x(95% CI 0.96-1.08), R-2=0.69. The limits of agreement of the un-calibrated COmf were -3.53 to 2.79, bias=0.37 litre min(-1) and of the diameter-calibrated method COmfc, - 1.48 to 1.32, bias=-0.08 litre min(-1). The coefficient of variation for the difference between methods decreased from 28 (un-calibrated) to 12% after diameter-calibration. Conclusions. After diameter-calibration, the improved modelflow pulse contour method reliably estimates cardiac output without the need of a calibration with thermodilution, leading to a less invasive cardiac output monitoring method.
引用
收藏
页码:326 / 331
页数:6
相关论文
共 18 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   ASSESSMENT OF WINDKESSEL AS A MODEL OF AORTIC INPUT IMPEDANCE [J].
BURKHOFF, D ;
ALEXANDER, J ;
SCHIPKE, J .
AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 255 (04) :H742-H753
[3]   Noninvasive cardiac output monitoring by aortic blood flow determination:: Evaluation of the Sometec Dynemo-3000 system [J].
Cariou, A ;
Monchi, M ;
Joly, LM ;
Bellenfant, F ;
Claessens, YE ;
Thébert, D ;
Brunet, F ;
Dhainaut, JF .
CRITICAL CARE MEDICINE, 1998, 26 (12) :2066-2072
[4]  
CRITCHLEY LAH, 1999, J CLIN MONITOR, V24, P1684
[5]   Continuous and intermittent cardiac output measurement:: pulmonary artery catheter versus aortic transpulmonary technique [J].
Della Rocca, G ;
Costa, MG ;
Pompei, L ;
Coccia, C ;
Pietropaoli, P .
BRITISH JOURNAL OF ANAESTHESIA, 2002, 88 (03) :350-356
[6]   Less invasive, continuous hemodynamic monitoring during minimally invasive coronary surgery [J].
Gödje, O ;
Thiel, C ;
Lamm, P ;
Reichenspurner, H ;
Schmitz, C ;
Schütz, A ;
Reichart, B .
ANNALS OF THORACIC SURGERY, 1999, 68 (04) :1532-1536
[7]   CONTINUOUS CARDIAC-OUTPUT MONITORING BY PULSE CONTOUR DURING CARDIAC-SURGERY [J].
JANSEN, JRC ;
WESSELING, KH ;
SETTELS, JJ ;
SCHREUDER, JJ .
EUROPEAN HEART JOURNAL, 1990, 11 :26-32
[8]   THE THERMODILUTION METHOD FOR THE CLINICAL-ASSESSMENT OF CARDIAC-OUTPUT [J].
JANSEN, JRC .
INTENSIVE CARE MEDICINE, 1995, 21 (08) :691-697
[9]   A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients [J].
Jansen, JRC ;
Schreuder, JJ ;
Mulier, JP ;
Smith, NT ;
Settels, JJ ;
Wesseling, KH .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (02) :212-222
[10]   Mean cardiac output by thermodilution with a single controlled injection [J].
Jansen, JRC ;
Schreuder, JJ ;
Punt, KD ;
van den Berg, PCM ;
Alfieri, O .
CRITICAL CARE MEDICINE, 2001, 29 (10) :1868-1873