Baseline radon detectors for shipboard use: Development and deployment in the First Aerosol Characterization Experiment (ACE 1)

被引:113
作者
Whittlestone, S [1 ]
Zahorowski, W [1 ]
机构
[1] ANSTO, Lucas Heights, NSW 2234, Australia
关键词
D O I
10.1029/98JD00687
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
A new design of two-filter radon detector has been developed for measurement of extremely low levels of radon in the harsh environments an board ships and remote islands. These were needed for the First Aerosol Characterization (ACE 1) multiplatform experiment in the Southern Ocean. By employing an internal recirculation system and a wire mesh screen as the second filter it has been possible to reduce the power consumption by as much as a factor of 10 and the weight and cost by a factor of 2 compared to current designs of comparable sensitivity. A very high efficiency of 0.38 count s(-1) Bq(-1) radon in the instrument has been achieved by counting while sampling. This is a key parameter because the larger this number, the smaller the volume and power consumption of the detector. Two air flow paths are used to separate the high flow rate needed to prevent loss of radon daughters to the walls of the detector and the lower flow rate needed to change the air sample in the instrument. As a result, the inlet air lines and delay chamber needed to remove thoron are compact. With a volume of 750 L the detectors used on board ships for ACE 1 bad a sensitivity of about 0.2 counts s(-1) Bq(-1) m(-3) and a lower limit of detection of 40 mBq m(-3) for a 1 hour count. An instrument with a volume of 10 m(3) and incorporating improvements made since ACE 1 could be expected to have sensitivity of 3.7 c s(-1) Bq(-1) m(-3) and a lower limit of detection of 2 mBq m(-3). At 45 min the time resolution is twice as good as that of instruments using a low internal flow rate, but not as good as instruments with a moving filter, where the sampling period is precisely defined. Dual-flow loop radon detectors with screens have the virtues of simplicity and freedom from routine maintenance. This new technology extends the range of sites at which baseline radon measurements can be made to remote areas with little regular technical support and a harsh environment.
引用
收藏
页码:16743 / 16751
页数:9
相关论文
共 25 条
[1]  
BATES TS, J GEOPHYS RES
[2]   THE NATURE OF UNATTACHED RAA (PO-218) PARTICLES [J].
BUSIGIN, A ;
VANDERVOOREN, AW ;
BABCOCK, JC ;
PHILLIPS, CR .
HEALTH PHYSICS, 1981, 40 (03) :333-343
[3]   THEORY OF A SCREEN-TYPE DIFFUSION BATTERY [J].
CHENG, YS ;
YEH, HC .
JOURNAL OF AEROSOL SCIENCE, 1980, 11 (03) :313-&
[4]   AN INTERNATIONAL INTERCOMPARISON OF MARINE ATMOSPHERIC RADON-222 MEASUREMENTS IN BERMUDA [J].
COLLE, R ;
UNTERWEGER, MP ;
HODGE, PA ;
HUTCHINSON, JMR ;
WHITTLESTONE, S ;
POLIAN, G ;
ARDOUIN, B ;
KAY, JG ;
FRIEND, JP ;
BLOMQUIST, BW ;
NADLER, W ;
DANG, TT ;
LARSEN, RJ ;
HUTTER, AR .
JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1995, 100 (D8) :16617-16638
[5]   An international marine-atmospheric Rn-222 measurement intercomparison in Bermuda .2. Results for the participating laboratories [J].
Colle, R ;
Unterweger, MP ;
Hutchinson, JMR ;
Whittlestone, S ;
Polian, G ;
Ardouin, B ;
Kay, JG ;
Friend, JP ;
Blomquist, BW ;
Nadler, W ;
Dang, TT ;
Larsen, RJ ;
Hutter, AR .
JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1996, 101 (01) :21-46
[6]   ENGINEERS GUIDE TO ELEMENTARY BEHAVIOR OF RADON DAUGHTERS [J].
EVANS, RD .
HEALTH PHYSICS, 1969, 17 (02) :229-+
[7]  
GEORGE AC, 1972, HEALTH PHYS, V23, P390
[8]   RADON AND CN - COMPLEMENTARY TRACERS OF POLLUTED AIR MASSES AT COASTAL AND ISLAND SITES [J].
GRAS, JL ;
WHITTLESTONE, S .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1992, 161 (01) :293-306
[9]  
GRUMM D, 1990, 1990 INT S RAD RAD T
[10]  
HUTTER AR, 1990, EML522 US DEP EN NAT