Validation and comparison of luminex multiplex cytokine analysis kits with ELISA: Determinations of a panel of nine cytokines in clinical sample culture supernatants

被引:239
作者
duPont, NC
Wang, KH
Wadhwa, PD
Culhane, JF
Nelson, EL
机构
[1] Univ Calif Irvine, Dept Obstet & Gynecol, Div Gynecol Oncol, Orange, CA 92868 USA
[2] Univ Calif Irvine, Dept Med, Div Hematol Oncol, Irvine, CA 92697 USA
[3] Univ Calif Irvine, Dept Psychiat & Human Behav, Irvine, CA 92697 USA
[4] Drew Univ, Coll Med, Sch Publ Hlth, Dept Obstet & Gynecol, Philadelphia, PA USA
[5] Univ Calif Irvine, Sch Biol Sci, Dept Mol Biol & Biochem, Irvine, CA 92697 USA
关键词
reproductive immunology; clinical study; cytokine; ELISA; luminex; multiplex analysis;
D O I
10.1016/j.jri.2005.03.005
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Problem: Analyses of the expression pattern of multiple cytokines are frequently required for characterization of the status of the immune system as it pertains to Th type bias and intrinsic levels of inflammation. Classically, analysis of cytokine expression patterns has been performed by enzyme-linked immunosorbent assays (ELISA) for each separate analyte. A new technology, Luminex MAP(R), facilitates the simultaneous evaluation of multiple immune mediators with advantages of higher throughput, smaller sample volume, and lower cost. Validation of this technology has been limited to small sample sets, limited use of clinical study specimens, and use of non-commercial reagents. Methods: Ninety-six specimens from women over the course of their respective pregnancies were evaluated for cytokine concentrations using commercially available ELISA kits and commercially available Luminex MAP(R) kits according to the manufacturers' directions. Correlations between data sets were evaluated using Pearson's correlation coefficient (r). Results: Excellent correlations were demonstrated for IL-1 beta, IL-4, IL-5, IL-6, IL-10, IFN gamma, and TNF alpha, in contrast to IL-12 p70 and IL-13. Conclusions: Luminex multiplex technology has distinct advantages and is a valid alternative method to ELISA for the evaluation of the majority of cytokines tested and for the characterization of immune system status. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:175 / 191
页数:17
相关论文
共 77 条
  • [1] Ader R., 2001, PSYCHONEUROIMMUNOLOG
  • [2] T-helper 2-cytokine levels in women with threatened abortion
    Balkanli-Kaplan, P
    Güçer, F
    Yüce, MA
    [J]. EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2004, 114 (02) : 239 - 240
  • [3] IL-15: The role of translational regulation in their expression
    Bamford, RN
    Battiata, AP
    Waldmann, TA
    [J]. JOURNAL OF LEUKOCYTE BIOLOGY, 1996, 59 (04) : 476 - 480
  • [4] Becher B, 2000, GLIA, V29, P293
  • [5] Besedovsky HO, 2000, Z RHEUMATOL, V59, P26, DOI 10.1007/s003930070014
  • [6] Comparison of a multiplexed fluorescent covalent microsphere immunoassay and an enzyme-linked immunosorbent assay for measurement of human immunoglobulin G antibodies to anthrax toxins
    Biagini, RE
    Sammons, DL
    Smith, JP
    MacKenzie, BA
    Striley, CAF
    Semenova, V
    Steward-Clark, E
    Stamey, K
    Freeman, AE
    Quinn, CP
    Snawder, JE
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2004, 11 (01) : 50 - 55
  • [7] Method for simultaneous measurement of antibodies to 23 pneumococcal capsular polysaccharides
    Biagini, RE
    Schlottmann, SA
    Sammons, DL
    Smith, JP
    Snawder, JC
    Striley, CAF
    MacKenzie, BA
    Weissman, DN
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2003, 10 (05) : 744 - 750
  • [8] Brailey Paul, 2003, Human Immunology, V64, pS117, DOI 10.1016/j.humimm.2003.08.220
  • [9] Flow cytometric microsphere-based immunoassay:: Analysis of secreted ctytokines in whole-blood samples from asthmatics
    Camilla, C
    Mély, L
    Magnan, A
    Casano, B
    Prato, S
    Debono, S
    Montero, F
    Defoort, JP
    Martin, M
    Fert, V
    [J]. CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, 2001, 8 (04) : 776 - 784
  • [10] Simultaneous quantitation of 15 cytokines using a multiplexed flow cytometric assay
    Carson, RT
    Vignali, DAA
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1999, 227 (1-2) : 41 - 52