Helical CT angiography in evaluation of live kidney donors

被引:50
作者
Patil, UD
Ragavan, A
Nadaraj
Murthy, K
Shankar, R
Bastani, B [1 ]
Ballal, SH
机构
[1] St Louis Univ, Sch Med, Div Nephrol, St Louis, MO 63110 USA
[2] Manipal Hosp, Div Nephrol, Bangalore, Karnataka, India
[3] Manipal Hosp, Div Radiol, Bangalore, Karnataka, India
[4] St Louis Univ, Sch Med, Div Radiol, St Louis, MO 63110 USA
关键词
donor evaluation; helical CT scan; renal angiography; transplantation;
D O I
10.1093/ndt/16.9.1900
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Live kidney donor evaluation mandates anatomical and functional assessment of the donor kidney. Helical computed tomography (CT) with advanced 3-D techniques provides detailed description of the vascular, parenchymal, and collecting system. Methods. We compared the accuracy of helical CT angiography with intra-operative findings in the evaluation of 102 live kidney donors. Results. Identification of vascular anomalies was best on direct viewing of the axial images using interactive scrolling through the images and cine-loop paging. In 204 kidneys evaluated, a single renal artery was present in 74.5% and a single renal vein in 87.5%. Multiple renal arteries were more common on the left side (31%) vs the right side (20%). Early branching of the arteries was seen with equal frequency (approximate to 10%) on either side. Multiple renal veins were more often on the right side (20%) vs the left side (5%), and one patient was found to have double inferior vena cava. CT angiographic, findings were concordant with the intra-operative findings in 97% of the cases, missing a small renal vein, an accessory artery that was visualized in retrospect, and a very early branch that was read as accessory artery. CT also revealed cortical cysts (four cases), duplex collecting system (two cases), hydronephrosis (one case), renal stone (one; case), and liver haemangioma (two cases). Conclusion. CT angiography is highly accurate for detecting vascular anomalies, and providing anatomical information. It may serve as the primary tool for donor evaluation.
引用
收藏
页码:1900 / 1904
页数:5
相关论文
共 16 条
[1]   Preoperative evaluation of living renal donors with gadolinium-enhanced magnetic resonance angiography [J].
Bakker, J ;
Ligtenberg, G ;
Beek, FJA ;
van Reedt Dortland, RWH ;
Hené, RJ .
TRANSPLANTATION, 1999, 67 (08) :1167-1172
[2]  
BARRETT BJ, 1994, J AM SOC NEPHROL, V5, P125
[3]   TECHNICAL OPTIMIZATION OF SPIRAL CT FOR DEPICTION OF RENAL-ARTERY STENOSIS - IN-VITRO ANALYSIS [J].
BRINK, JA ;
LIM, JT ;
WANG, G ;
HEIKEN, JP ;
DEYOE, LA ;
VANNIER, MW .
RADIOLOGY, 1995, 194 (01) :157-163
[4]   Use of gadolinium-enhanced, ultrafast, three-dimensional, spoiled gradient-echo magnetic resonance angiography in the preoperative evaluation of living renal allograft donors [J].
Buzzas, GR ;
Shield, CF ;
Pay, NT ;
Neuman, MJ ;
Smith, JL .
TRANSPLANTATION, 1997, 64 (12) :1734-1737
[5]   Helical CT angiography for examination of living renal donors [J].
Cochran, ST ;
Krasny, RM ;
Danovitch, GM ;
Rajfer, J ;
Barbaric, ZM ;
Wilkinson, A ;
Rosenthal, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (06) :1569-1573
[6]   Helical CT examination of potential kidney donors [J].
Dachman, AH ;
Newmark, GM ;
Mitchell, MT ;
Woodle, ES .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) :193-200
[7]   Helical computerized tomography arteriography for evaluation of live renal donors undergoing laparoscopic nephrectomy [J].
Del Pizzo, JJ ;
Sklar, GN ;
You-Cheong, JW ;
Levin, B ;
Krebs, T ;
Jacobs, SC .
JOURNAL OF UROLOGY, 1999, 162 (01) :31-34
[8]  
KAYNAN AM, 1999, J UROLOGY, V161, P1969
[9]   Interactive 3-dimensional computerized tomography reconstruction in evaluation of living renal donor [J].
Lerner, LB ;
Henriques, HF ;
Harris, RD .
JOURNAL OF UROLOGY, 1999, 161 (02) :403-407
[10]   Potential renal transplant donors: Evaluation with gadolinium-enhanced MR angiography and MR urography [J].
Low, RN ;
Martinez, AG ;
Steinberg, SM ;
Alzate, GD ;
Kortman, KE ;
Bower, BB ;
Dwyer, WJ ;
Prince, SK .
RADIOLOGY, 1998, 207 (01) :165-172