Determination of muscle loading at the hip joint for use in pre-clinical testing

被引:290
作者
Heller, MO
Bergmann, G
Kassi, JP
Claes, L
Haas, NP
Duda, GN
机构
[1] Humboldt Univ, D-13353 Berlin, Germany
[2] Free Univ Berlin, Biomech Lab, D-1000 Berlin, Germany
[3] Univ Ulm, Inst Orthopaed Res & Biomech, D-89069 Ulm, Germany
关键词
hip joint; loading; joint contact; muscle forces; simulation; pre-clinical testing;
D O I
10.1016/j.jbiomech.2004.05.022
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The stability of joint endoprostheses depends on the loading conditions to which the implant-bone complex is exposed. Due to a lack of appropriate muscle force data, less complex loading conditions tend to be considered in vitro. The goal of this study was to develop a load profile that better simulates the in vivo loading conditions of a "typical" total hip replacement patient and considers the interdependence of muscle and joint forces. The development of the load profile was based on a computer model of the lower extremities that has been validated against in vivo data. This model was simplified by grouping functionally similar hip muscles. Muscle and joint contact forces were computed for an average data set of up to four patients throughout walking and stair climbing. The calculated hip contact forces were compared to the average of the in vivo measured forces. The final derived load profile included the forces of up to four muscles at the instances of maximum in vivo hip joint loading during both walking and stair climbing. The hip contact forces differed by less than 10% from the peak in vivo value for a "typical" patient. The derived load profile presented here is the first that is based on validated musculoskeletal analyses and seems achievable in an in vitro test set-up. It should therefore form the basis for further standardisation of pre-clinical testing by providing a more realistic approximation of physiological loading conditions. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1155 / 1163
页数:9
相关论文
共 60 条
[1]
Changes in proximal femoral strain after insertion of uncemented standard and customised femoral stems [J].
Aamodt, A ;
Lund-Larsen, J ;
Eine, J ;
Andersen, E ;
Benum, P ;
Husby, OS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06) :921-929
[2]
Endurance testing of hip prostheses: a comparison between the load fixed in ISO 7206 standard and the physiological loads [J].
Baleani, M ;
Cristofolini, L ;
Viceconti, M .
CLINICAL BIOMECHANICS, 1999, 14 (05) :339-345
[3]
Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[4]
Averaging of strongly varying signals [J].
Bergmann, G ;
Gandini, R ;
Ruder, H .
BIOMEDIZINISCHE TECHNIK, 2001, 46 (06) :168-171
[5]
IS STAIRCASE WALKING A RISK FOR THE FIXATION OF HIP IMPLANTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1995, 28 (05) :535-553
[6]
Bergmann G., 2001, HIP98 LOADING HIP JO
[7]
STEM CURVATURE AND LOAD ANGLE INFLUENCE THE INITIAL RELATIVE BONE-IMPLANT MOTION OF CEMENTLESS FEMORAL STEMS [J].
BERZINS, A ;
SUMNER, DR ;
ANDRIACCHI, TP ;
GALANTE, JO .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1993, 11 (05) :758-769
[8]
BLACK J, 1989, ORTHOP CLIN N AM, V20, P1
[9]
Brand R A, 1994, J Arthroplasty, V9, P45, DOI 10.1016/0883-5403(94)90136-8
[10]
THE SENSITIVITY OF MUSCLE FORCE PREDICTIONS TO CHANGES IN PHYSIOLOGICAL CROSS-SECTIONAL AREA [J].
BRAND, RA ;
PEDERSEN, DR ;
FRIEDERICH, JA .
JOURNAL OF BIOMECHANICS, 1986, 19 (08) :589-596