Changes in proximal femoral strain after insertion of uncemented standard and customised femoral stems

被引:63
作者
Aamodt, A [1 ]
Lund-Larsen, J [1 ]
Eine, J [1 ]
Andersen, E [1 ]
Benum, P [1 ]
Husby, OS [1 ]
机构
[1] Univ Trondheim Hosp, Dept Orthopaed Surg, Biomech Lab, N-7006 Trondheim, Norway
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2001年 / 83B卷 / 06期
关键词
D O I
10.1302/0301-620X.83B6.9726
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We have compared the changes in the pattern of the principal strains in the proximal femur after insertion of eight uncemented anatomical stems and eight customised stems in human cadaver femora. During testing we aimed to reproduce the physiological loads on the proximal femur and to simulate single-leg stance and stair-climbing. The strains in the intact femora were measured and there were no significant differences in principal tensile and compressive strains in the left and right femora of each pair. The two types of femoral stem were then inserted randomly into the left or right femora and the cortical strains were again measured. Both induced significant stress shielding in the proximal part of the metaphysis, but the deviation from the physiological strains was most pronounced after insertion of the anatomical stems. The principal compressive strain at the calcar was reduced by 90% for the anatomical stems and 67% for the customised stems. Medially, at the level of the lesser trochanter, the corresponding figures were 59% and 21%. The anatomical stems induced more stress concentration on the anterior aspect of the femur than did the customised stems. They also increased the hoop strains in the proximomedial femur. Our study shows a consistently more physiological pattern of strain in the proximal femur after insertion of customised stems compared with standard, anatomical stems.
引用
收藏
页码:921 / 929
页数:9
相关论文
共 37 条
[1]   In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur [J].
Aamodt, A ;
Lund-Larsen, J ;
Eine, J ;
Andersen, E ;
Benum, P ;
Husby, OS .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (06) :927-931
[2]   Determination of the Hounsfield value for CT-based design of custom femoral stems [J].
Aamodt, A ;
Kvistad, KA ;
Andersen, E ;
Lund-Larsen, J ;
Eine, J ;
Benum, P ;
Husby, OS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1999, 81B (01) :143-147
[3]  
AAMODT A, IN PRESS HIP INT
[4]  
AAMODT A, 1996, ACT ORTHOP SCAN S270, V67, P16
[5]  
BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
[6]   ROLE OF LOADS AND PROSTHESIS MATERIAL PROPERTIES ON THE MECHANICS OF THE PROXIMAL FEMUR AFTER TOTAL HIP-ARTHROPLASTY [J].
CHEAL, EJ ;
SPECTOR, M ;
HAYES, WC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (03) :405-422
[7]  
Clarke H J, 1992, J Arthroplasty, V7, P235, DOI 10.1016/0883-5403(92)90042-O
[8]   A critical analysis of stress shielding evaluation of hip prostheses [J].
Cristofolini, L .
CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 1997, 25 (4-5) :409-483
[9]   INFLUENCE OF THIGH MUSCLES ON THE AXIAL STRAINS IN A PROXIMAL FEMUR DURING EARLY STANCE IN GAIT [J].
CRISTOFOLINI, L ;
VICECONTI, M ;
TONI, A ;
GIUNTI, A .
JOURNAL OF BIOMECHANICS, 1995, 28 (05) :617-624
[10]   In vitro stress shielding measurements can be affected by large errors [J].
Cristofolini, L ;
Viceconti, M .
JOURNAL OF ARTHROPLASTY, 1999, 14 (02) :215-219