Fluid absorption study in ultra-high molecular weight polyethylene( UHMWPE) sterilized and unsterilized acetabular cups

被引:25
作者
Affatato, S
Vandelli, C
Bordini, B
Toni, A
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Ist Ortoped Rizzoli, Div 1, I-40136 Bologna, Italy
关键词
water absorption; serum absorption; polyethylene absorption; fluid absorption; hip simulator;
D O I
10.1243/0954411011533463
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The weight gain due to fluid absorption was measured in gamma -sterilized, ethylene oxide (ETO) gas-sterilized, and unsterilized ultra-high molecular weight (UHMW) polyethylene acetabular cups. After about 2 months the total average fluid absorption gain of the polyethylene cups was: 1.76 +/- 0.45 mg (average +/- standard deviation) for the unsterilized polyethylene cups, 2.81 +/- 0.95 mg for the gamma -sterilized polyethylene cups and 1.51 +/- 0.34 for the ETO gas-sterilized polyethylene cups. There was little difference in fluid absorption between the sterilized and unsterilized specimens. In particular, the gamma -sterilized acetabular cups absorbed more than the ETO gas-sterilized and the unsterilized cups. However, the weight gain was higher in serum compared with that in water.
引用
收藏
页码:107 / 111
页数:5
相关论文
共 18 条
[1]   Hip prothesis:: an in vitro wear protocol based on a comparison between gravimetric and profilometric analysis [J].
Affatato, S ;
Tagliati, M ;
Toni, A .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1999, 22 (04) :226-229
[2]   The influence of lubricant on the morphology of ultra-high molecular weight polyethylene wear debris generated in laboratory tests [J].
Besong, AA ;
Tipper, JL ;
Mathews, BJ ;
Ingham, E ;
Stone, MH ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H2) :155-158
[3]   EVALUATION OF HIP ARTHROPROSTHESES BY MEANS OF BODY ENVIRONMENT SIMULATORS [J].
CAPPOZZO, A ;
CINI, L ;
PIZZOFERRATO, A ;
TRENTANI, C ;
CORTESI, SS .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1977, 11 (05) :657-669
[4]   ROUGHNESS MEASUREMENT WITH A LASER SCANNING ANALYZER [J].
CLARKE, GM ;
THOMAS, TR .
WEAR, 1979, 57 (01) :107-116
[5]   FLUID-SORPTION PHENOMENA IN STERILIZED POLYETHYLENE ACETABULAR PROSTHESES [J].
CLARKE, IC ;
STARKEBAUM, W ;
HOSSEINIAN, A ;
MCGUIRE, P ;
OKUDA, R ;
SALOVEY, R ;
YOUNG, R .
BIOMATERIALS, 1985, 6 (03) :184-188
[6]   Hip-simulator ranking of polyethylene wear - Comparisons between ceramic heads of different sizes [J].
Clarke, IC ;
Gustafson, A ;
Jung, H ;
Fujisawa, A .
ACTA ORTHOPAEDICA SCANDINAVICA, 1996, 67 (02) :128-132
[7]  
EIFFE VC, 1998, HIP INT, V8, P1
[8]  
ILCHMANN T, 1998, HIP INT, V8, P16
[9]  
KRANEZIS IA, 1999, HIP INT, V9, P25
[10]   Femoral component wear in retrieved hip prostheses [J].
Kusaba, A ;
Kuroki, Y .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (02) :331-336