Clinical step onward with X-ray dark-field imaging and perspective view of medical applications of synchrotron radiation in Japan

被引:22
作者
Ando, M
Hashimoto, E
Hashizume, H
Hyodo, K
Inoue, H
Kunisada, T
Maksimenko, A
Mori, K
Rubenstein, E
Roberson, J
Shimao, D
Sugiyama, H
Takeda, K
Toyofuku, F
Ueno, E
Umetani, K
Wada, H
Pattanasiriwisawa, W
机构
[1] Natl Lab High Energy Phys, KEK, Photon Factory, Tsukuba, Ibaraki 3050801, Japan
[2] GUAS, Dept Photo Sci, Sch Adv Studies, Tsukuba, Ibaraki 3050801, Japan
[3] GUAS, Dept Mat Struct Sci, Sch High Energy Accelerator Sci, Tsukuba, Ibaraki 3050801, Japan
[4] Okayama Univ, Grad Sch Med & Dent, Study Biofunct Recovery & Reconstruct Plast & Rec, Okayama 7008558, Japan
[5] Stanford Univ, Sch Med, Dept Med, Stanford, CA 94305 USA
[6] Calif Ear Inst, Palo Alto, CA 94304 USA
[7] Kyushu Univ, Sch Hlth Sci, Fac Med, Higashi Ku, Fukuoka 8128582, Japan
[8] Univ Tsukuba, Dept Breast Tyroid Endocrine Surg, Inst Clin Med, Tsukuba, Ibaraki 3058571, Japan
[9] JASRI, Sayo, Hyogo 6795198, Japan
[10] Tohoku Univ, Dept Biorobot, Sch Engn, Sendai, Miyagi 9808579, Japan
[11] Suranaree Univ Technol, Dept Phys, Nakhon Ratchasima 30000, Thailand
[12] Ibaraki Prefectural Univ Hlth Sci, Dept Radiol Sci, Inashiki, Ibaraki 3000394, Japan
关键词
SPring-8; KEK; photon factory; synchrotron radiation; clinical application; X-ray dark-field imaging; monochrocollimator; laue diffraction filter; refraction; pseudoclinical diagnosis; excised human femoral head; articular;
D O I
10.1016/j.nima.2005.03.059
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper reports, the application of synchrotron radiation to basic medicine at SPring-8 involving instrumentation and medical application of imaging and scattering. Emphasis should be laid on X-ray dark-field imaging (DFI) whose goal is clinical diagnosis of organs that have been invisible by ordinary techniques. Development of this technique is under way both at SPring-8 and KEK. The X-ray optics of DFI comprises a Bragg asymmetric monochro-collimator and a Lane case analyzer with a diffraction index of 4 4 0 using the X-ray energy of 35 keV (lambda = 0.0354 nm) in a parallel position. This analyzer that can provide with 80 mm x 80 mm view size has 2.15 mm thickness. At present the spatial resolution is around 5-10 mu m. Visibility of some organs such as soft bone tissue at excised human femoral head and breast cancer tissue is under test. This preliminary test shows that the DFI seems feasible in clinical diagnosis. Furthermore, a perspective view of application of synchrotron radiation to clinical medicine in Japan will be given. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 70 条
[1]   AN ATTEMPT AT CORONARY ANGIOGRAPHY WITH A LARGE SIZE MONOCHROMATIC SR BEAM [J].
AKISADA, A ;
ANDO, M ;
HYODO, K ;
HASEGAWA, S ;
KONISHI, K ;
NISHIMURA, K ;
MARUHASHI, A ;
TOYOFUKU, F ;
SUWA, A ;
KOHRA, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :713-718
[2]   Attempt at visualizing breast cancer with X-ray dark field imaging [J].
Ando, M ;
Yamasaki, K ;
Toyofuku, F ;
Sugiyama, H ;
Ohbayashi, C ;
Li, G ;
Pan, L ;
Jiang, XM ;
Pattanasiriwisawa, W ;
Shimao, D ;
Hashimoto, E ;
Kimura, T ;
Tsuneyoshi, M ;
Ueno, E ;
Tokumori, K ;
Maksimenko, A ;
Higashida, Y ;
Hirano, M .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2005, 44 (16-19) :L528-L531
[3]   Construction of X-ray dark-field Imaging with a view size of 80 mm square and first visualization of human articular cartilage of femoral head under a nearly clinical condition [J].
Ando, M ;
Sugiyama, H ;
Kunisada, T ;
Shimao, D ;
Takeda, K ;
Hashizume, H ;
Inoue, H .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2004, 43 (9A-B) :L1175-L1177
[4]   Simple X-ray dark- and bright-field imaging using achromatic lane optics [J].
Ando, M ;
Maksimenko, A ;
Sugiyama, H ;
Pattanasiriwisawa, W ;
Hyodo, K ;
Uyama, C .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2002, 41 (9A-B) :L1016-L1018
[5]   An X-ray trichrome imaging 'trinity': Absorption, phase-interference and angle-resolved contrast [J].
Ando, M ;
Sugiyama, H ;
Zhang, XW ;
Hyodo, K ;
Maksimenko, A ;
Pattanasiriwisawa, W .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2001, 40 (3B) :L298-L301
[6]  
[Anonymous], 1991, HDB SYNCHROTRON RAD
[7]   MAMMOGRAPHY WITH SYNCHROTRON-RADIATION [J].
BURATTINI, E ;
COSSU, E ;
DIMAGGIO, C ;
GAMBACCINI, M ;
INDOVINA, PL ;
MARZIANI, M ;
POCEK, M ;
SIMEONI, S ;
SIMONETTI, G .
RADIOLOGY, 1995, 195 (01) :239-244
[8]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[9]  
CHIKAWA J, COMMUNICATION
[10]   NEW X-RAY TOPOGRAPHIC TECHNIQUE FOR DETECTION OF SMALL DEFECTS IN HIGHLY PERFECT CRYSTALS [J].
CHIKAWA, JI ;
ASAEDA, Y ;
FUJIMOTO, I .
JOURNAL OF APPLIED PHYSICS, 1970, 41 (05) :1922-&