Atomic spectrometry update. Industrial analysis: metals, chemicals and advanced materials

被引:13
作者
Fisher, A
Goodall, PS
Hinds, MW
Nelms, SM
Penny, DM
机构
[1] Univ Plymouth, Sch Earth Ocean & Environm Sci, Plymouth PL4 8AA, Devon, England
[2] BNFL, Seascale CA20 1PG, Cumbria, England
[3] Royal Canadian Mint, Ottawa, ON K1A 0G8, Canada
[4] Thermo Electron Corp, Winsford CW7 3BX, Cheshire, England
[5] Shell Res & Technol Ctr, Chester CH1 3SH, Cheshire, England
关键词
D O I
10.1039/b314153p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This Atomic Spectrometry Update is the latest in an annual series(1) under the title 'Industrial Analysis'. The writing team has remained unchanged this year, although the writing duties have been re-arranged slightly. The general structure of the review is fundamentally the same as in previous years' but in an,attempt to keep the review focused on, atomic spectrometry, there have been a few omissions. Included in these omissions are numerous papers that have described the derivatization of a commercial resin with an organic functional group, so that analytes may be. preconcentrated and/or separated from the matrix. Although the chemistry is interesting in such papers, it was thought that this does not really count as being analysis of an organic chemical nor, in most cases, was it a serious advance in knowledge of atomic spectrometry. The use of SIMS as a depth-profiling tool is still extremely common. Many papers however give little detail on the atomic spectroscopy side and inclusion of all the papers would lead to an enormous number of references whilst adding very little in the way of detail. Therefore, only a few papers have been chosen to give the,reader a taste of what research is being performed. The use of LIBS appears to be gaining popularity, especially in the area of metals analysis, although applications for polymers, ceramics and semi-conductors have also appeared. Much of the methodology reported in the organics section, is similar to that described in previous reviews with only relatively minor tweaks but in some areas, e.g. oils, the introduction of more advanced techniques have been reported. This is a function of the more ambitious analyses being performed requiring more imaginative techniques to be employed to ensure success.
引用
收藏
页码:1497 / 1528
页数:32
相关论文
共 408 条
[51]   Design and simulation of antireflection coating for application to silicon solar cells [J].
Chakravarty, BC ;
Vinod, PN ;
Singh, SN ;
Chakraborty, BR .
SOLAR ENERGY MATERIALS AND SOLAR CELLS, 2002, 73 (01) :59-66
[52]   A rapid method for the determination of mercury in mainstream cigarette smoke by two-stage amalgamation cold vapor atomic absorption spectrometry [J].
Chang, MJ ;
McDaniel, RL ;
Naworal, JD ;
Self, DA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (07) :710-715
[53]   Absolute isotopic composition and atomic weight of samariurn [J].
Chang, TL ;
Zhao, MT ;
Li, WJ ;
Wang, J ;
Qian, QY .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 218 (02) :167-172
[54]   Determination of heavy metals in industrial wastes by SXRF method [J].
Chatterjee, JM ;
Sarkar, M ;
Roy, S ;
Weidenbrü, K .
RADIATION PHYSICS AND CHEMISTRY, 2002, 64 (5-6) :369-372
[55]  
Chen M, 2001, FERROELECTRICS, V263, P1573, DOI 10.1080/00150190108225211
[56]   242Pu as tracer for simultaneous determination of 237Np and 239,240Pu in environmental samples [J].
Chen, QJ ;
Dahlgaard, H ;
Nielsen, SP ;
Aarkrog, A .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 253 (03) :451-458
[57]   Non-destructive analysis and appraisal of ancient Chinese pocelain by PIXE [J].
Cheng, HS ;
Zhang, ZQ ;
Xia, HN ;
Jiang, JC ;
Yang, FJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 190 :488-491
[58]   High precision measurements of arsenic and phosphorous implantation dose in silicon by secondary ion mass spectrometry [J].
Chi, PH ;
Simons, DS ;
McKinley, JM ;
Stevie, FA ;
Granger, CN .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2002, 20 (03) :688-692
[59]   Sample preparation for quantitation of tritium by accelerator mass spectrometry [J].
Chiarappa-Zucca, ML ;
Dingley, KH ;
Roberts, ML ;
Velsko, CA ;
Love, AH .
ANALYTICAL CHEMISTRY, 2002, 74 (24) :6285-6290
[60]   Measurement of low currents in an external beam set-up [J].
Chiari, M ;
Migliori, A ;
Mandò, PA .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 188 :162-165