Direct and simultaneous determination of copper, chromium, aluminum, and manganese in urine with a multielement graphite furnace atomic absorption spectrometer

被引:199
作者
Lin, TW [1 ]
Huang, SD [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, Hsinchu 300, Taiwan
关键词
D O I
10.1021/ac010319h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method was developed for the direct and simultaneous determination of copper, chromium, aluminum, and manganese in urine using a multielement GFAAS (Perkin-Elmer SIMAA6000). Pd was used as the chemical modifier along with a special purge gas (5% H-2 in Ar). A simple calibration curve method can be used (with 1:1 dilution). A standard reference material (Seronorm Trace Elements Urine) was used to find the optimal temperature program and to confirm the accuracy of the technique. The analyzed values were within 90-110% of the certified values. The relative standard deviations were 1.7, 1.5, 1.6, and 1.5% for these four elements and the detection limits were 0.08 mug L-1 for Cu, 0.05 mug L-1 for Cr, 0.06 mug L-1 for Al, and 0.06 mug L-1 for Mn. The recoveries of Cu, Cr, Al, and Mn from real urine samples were 100 5%, except for Cu (80%). The found values of Cu, Cr, Al, and Mn in a real urine sample were 14.3, 0.78, 18.9, and 0.06 mug L-1, respectively. Scanning electron micrographs were used to investigate the physical form of Pd on the surface of the platform in the graphite furnace. Use of 5% H-2 in Ar as the purge gas resulted in smaller and more uniformly distributed Pd particles (Pd particle diameters 0.4-0.6 mum using 5% H-2 in Ar compared to 0.4-1.2 mum using pure Ar), increasing the effect of the Pd chemical modifier and promoting the efficiency of atomization.
引用
收藏
页码:4319 / 4325
页数:7
相关论文
共 42 条
[21]   Investigations into the simultaneous determination of bismuth and selenium by 'in atomizer trapping' electrothermal atomic absorption spectrometry [J].
Murphy, J ;
Jones, P ;
Schlemmer, G ;
Shuttler, IL ;
Hill, SJ .
ANALYTICAL COMMUNICATIONS, 1997, 34 (11) :359-362
[22]   Simultaneous multi-element determination of hydride-forming elements by "in-atomiser trapping" electrothermal atomic absorption spectrometry on an iridium-coated graphite tube [J].
Murphy, J ;
Schlemmer, G ;
Shuttler, IL ;
Jones, P ;
Hill, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (10) :1593-1600
[23]  
NORSETH T, 1979, HDB TOXICOLOGY METAL, P275
[24]  
PETHES G, 1980, ELEMENT ANAL BIOL MA, P3
[25]  
PISCATOR M, 1979, HDB TOXICOLOGY METAL, P185
[26]   MECHANISM OF MODIFICATION BY PALLADIUM IN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
QIAO, HC ;
JACKSON, KW .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (14) :1841-1859
[27]  
REES EL, 1979, J ORTHOMOL MED, V8, P37
[29]   PALLADIUM AND MAGNESIUM NITRATES, A MORE UNIVERSAL MODIFIER FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
SCHLEMMER, G ;
WELZ, B .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1986, 41 (11) :1157-1165
[30]  
SEARS D, 1998, PE NEWSL, V11, P48