Direct and simultaneous determination of copper, chromium, aluminum, and manganese in urine with a multielement graphite furnace atomic absorption spectrometer

被引:199
作者
Lin, TW [1 ]
Huang, SD [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, Hsinchu 300, Taiwan
关键词
D O I
10.1021/ac010319h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method was developed for the direct and simultaneous determination of copper, chromium, aluminum, and manganese in urine using a multielement GFAAS (Perkin-Elmer SIMAA6000). Pd was used as the chemical modifier along with a special purge gas (5% H-2 in Ar). A simple calibration curve method can be used (with 1:1 dilution). A standard reference material (Seronorm Trace Elements Urine) was used to find the optimal temperature program and to confirm the accuracy of the technique. The analyzed values were within 90-110% of the certified values. The relative standard deviations were 1.7, 1.5, 1.6, and 1.5% for these four elements and the detection limits were 0.08 mug L-1 for Cu, 0.05 mug L-1 for Cr, 0.06 mug L-1 for Al, and 0.06 mug L-1 for Mn. The recoveries of Cu, Cr, Al, and Mn from real urine samples were 100 5%, except for Cu (80%). The found values of Cu, Cr, Al, and Mn in a real urine sample were 14.3, 0.78, 18.9, and 0.06 mug L-1, respectively. Scanning electron micrographs were used to investigate the physical form of Pd on the surface of the platform in the graphite furnace. Use of 5% H-2 in Ar as the purge gas resulted in smaller and more uniformly distributed Pd particles (Pd particle diameters 0.4-0.6 mum using 5% H-2 in Ar compared to 0.4-1.2 mum using pure Ar), increasing the effect of the Pd chemical modifier and promoting the efficiency of atomization.
引用
收藏
页码:4319 / 4325
页数:7
相关论文
共 42 条
[32]   GRAPHITE-FURNACE AAS - APPLICATION OF REDUCED PALLADIUM AS A CHEMICAL MODIFIER [J].
SHRADER, DE ;
BEACH, LM ;
RETTBERG, TM .
JOURNAL OF RESEARCH OF THE NATIONAL BUREAU OF STANDARDS, 1988, 93 (03) :450-452
[33]   Direct and simultaneous determination of molybdenum and vanadium in sea-water using a multielement electrothermal atomic absorption spectrometer [J].
Su, PG ;
Huang, SD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (07) :641-645
[34]  
SU PG, 1998, SPECTROCHIM ACTA, V55, P708
[35]  
Teraoka H., 1981, Journal of the Japanese Society of Food and Nutrition [Eiyo to Shokuryo], V34, P221
[36]  
TSALEV DL, 1984, OCCUPATIONAL ENV HLT, V2
[37]   INVESTIGATIONS OF A REDUCED PALLADIUM CHEMICAL MODIFIER FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
VOTHBEACH, LM ;
SHRADER, DE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (01) :45-50
[38]   BIOLOGICALLY-ACTIVE METALS IN HUMAN TISSUES .1. EFFECT OF AGE AND SEX ON CONCENTRATION OF COPPER IN AORTA, HEART, KIDNEY, LIVER, LUNG, PANCREAS AND SKELETAL-MUSCLE [J].
VUORI, E ;
HUUNANSEPPALA, A ;
KILPIO, JO .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1978, 4 (02) :167-175
[39]  
WAWSCHINEK O, 1982, MIKROCHIM ACTA, V1, P335
[40]   PALLADIUM NITRATE - MAGNESIUM-NITRATE MODIFIER FOR GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY .2. DETERMINATION OF ARSENIC, CADMIUM, COPPER, MANGANESE, LEAD, ANTIMONY, SELENIUM AND THALLIUM IN WATER [J].
WELZ, B ;
SCHLEMMER, G ;
MUDAKAVI, JR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (05) :695-701