Quantification of coronary artery calcium using multidetector CT and a retrospective ECG-gating reconstruction algorithm

被引:39
作者
Horiguchi, J
Nakanishi, T
Ito, K
机构
[1] Hiroshima Univ, Sch Med, Dept Radiol, Minami Ku, Hiroshima 7348551, Japan
[2] Mazda Hosp, Dept Radiol, Huchu, Hiroshima 7350017, Japan
关键词
D O I
10.2214/ajr.177.6.1771429
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to evaluate the quality of and motion artifacts on multidetector CT scans and to compare the results with those of and on electron beam CT scans for the assessment of coronary calcium scores. MATERIALS AND METHODS. First, 20 volunteers were scanned using multidetector CT. We compared the signal-to-noise ratio in the heart, motion artifacts at the heart border, and the highest CT values in the regions of the coronary arteries using single-sector and multisector reconstruction algorithms. Next, 60 patients with coronary calcified deposits underwent both multidetector CT and electron beam CT. We compared coronary calcium scores determined with multidetector CT using the two algorithms (thresholds of 90 and 130 H) with those determined using electron beam CT. RESULTS. The signal-to-noise ratio was higher and motion artifacts were reduced when we used. the multisector algorithm. The highest CT value in the region of the coronary arteries exceeded 90 H in one of 55 arteries on the multisector algorithm images and 17 of 55 arteries on single-sector algorithm images (chi-square test, p < 0.01). In coronary calcium scoring, correlation coefficients ranged from 0.920 to 0.992 (Pearson's product moment) and from 0.932 to 0.969 (Spearman's rank correlation coefficient). CONCLUSION. Multidetector CT with a retrospective ECG-gating algorithm (multisector reconstruction) produced cardiac images with fewer motion artifacts and showed a high correlation with coronary calcium scores determined using electron beam CT. Therefore, multidetector CT is a potential tool for coronary calcium scoring.
引用
收藏
页码:1429 / 1435
页数:7
相关论文
共 26 条
[1]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[2]   QUANTIFICATION OF CORONARY-ARTERY CALCIUM USING ULTRAFAST COMPUTED-TOMOGRAPHY [J].
AGATSTON, AS ;
JANOWITZ, WR ;
HILDNER, FJ ;
ZUSMER, NR ;
VIAMONTE, M ;
DETRANO, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (04) :827-832
[3]  
BASKIN KM, 1995, CIRCULATION S1, V92, P651
[4]   Visualization and quantification of coronary calcifications with electron beam and spiral computed tomography [J].
Becker, CR ;
Knez, A ;
Ohnesorge, B ;
Schoepf, UJ ;
Flohr, T ;
Bruening, R ;
Haberl, R ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2000, 10 (04) :629-635
[5]   Helical and single-slice conventional CT versus electron beam CT for the quantification of coronary artery calcification [J].
Becker, CR ;
Jakobs, TF ;
Aydemir, S ;
Becker, A ;
Knez, A ;
Schoepf, UJ ;
Bruening, R ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (02) :543-547
[6]   Coronary artery calcium measurement: Agreement of multirow detector and electron beam CP [J].
Becker, CR ;
Kleffel, T ;
Crispin, A ;
Knez, A ;
Young, J ;
Schoepf, UJ ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1295-1298
[7]   SMALL LESIONS IN THE HEART IDENTIFIED AT ELECTRON-BEAM CT - CALCIFICATION OR NOISE [J].
BIELAK, LF ;
KAUFMANN, RB ;
MOLL, PP ;
MCCOLLOUGH, CH ;
SCHWARTZ, RS ;
SHEEDY, PF .
RADIOLOGY, 1994, 192 (03) :631-636
[8]   CORONARY-ARTERY CALCIFICATION DETECTED WITH ULTRAFAST CT AS AN INDICATION OF CORONARY-ARTERY DISEASE - WORK IN PROGRESS [J].
BREEN, JF ;
SHEEDY, PF ;
SCHWARTZ, RS ;
STANSON, AW ;
KAUFMANN, RB ;
MOLL, PP ;
RUMBERGER, JA .
RADIOLOGY, 1992, 185 (02) :435-439
[9]   Measurement of coronary artery calcium with dual-slice helical CT compared with coronary angiography: Evaluation of CT scoring methods, interobserver variations, and reproducibility [J].
Broderick, LS ;
Shemesh, J ;
Wilensky, RL ;
Eckert, GJ ;
Zhou, XH ;
Torres, WE ;
Balk, MA ;
Rogers, WJ ;
Conces, DJ ;
Kopecky, KK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) :439-444
[10]   Evaluation of subsecond gated helical CT for quantification of coronary artery calcium and comparison with electron beam CT [J].
Carr, JJ ;
Crouse, JR ;
Goff, DC ;
D'Agostino, RB ;
Peterson, NP ;
Burke, GL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :915-921