World-to-chip microfluidic interface with built-in valves for multichamber chip-based PCR assays

被引:41
作者
Oh, KW [1 ]
Park, CS [1 ]
Namkoong, K [1 ]
Kim, J [1 ]
Ock, KS [1 ]
Kim, S [1 ]
Kim, YA [1 ]
Cho, YK [1 ]
Ko, C [1 ]
机构
[1] Samsung Adv Inst Technol, Bio Lab, Suwon 440600, South Korea
关键词
D O I
10.1039/b503437j
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report a practical world-to-chip microfluidic interfacing method with built-in valves suitable for microscale multichamber chip-based assays. One of the primary challenges associated with the successful commercialization of fully integrated microfluidic systems has been the lack of reliable world-to-chip microfluidic interconnections. After sample loading and sealing, leakage tests were conducted at 100 degrees C for 30 min and no detectable leakage flows were found during the test for 100 microchambers. To demonstrate the utility of our world-to-chip microfluidic interface, we designed a microscale PCR chip with four chambers and performed PCR assays. The PCR results yielded a 100% success rate with no contamination or leakage failures. In conclusion, we have introduced a simple and inexpensive microfluidic interfacing system for both sample loading and sealing with no dead volume, no leakage flow and biochemical compatibility.
引用
收藏
页码:845 / 850
页数:6
相关论文
共 49 条
[41]   The burgeoning power of the shrinking laboratory [J].
Ramsey, JM .
NATURE BIOTECHNOLOGY, 1999, 17 (11) :1061-1062
[42]  
Sato K, 2002, ELECTROPHORESIS, V23, P734, DOI 10.1002/1522-2683(200203)23:5<734::AID-ELPS734>3.0.CO
[43]  
2-W
[44]   Cell lysis and protein extraction in a microfluidic device with detection by a fluorogenic enzyme assay [J].
Schilling, EA ;
Kamholz, AE ;
Yager, P .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1798-1804
[45]   Single-cell analysis by a scanning thermal lens microscope with a microchip:: Direct monitoring of cytochrome c distribution during apoptosis process [J].
Tamaki, E ;
Sato, K ;
Tokeshi, M ;
Sato, K ;
Aihara, M ;
Kitamori, T .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1560-1564
[46]   SoFAR:: Software for fully automatic evaluation of real-time PCR data [J].
Wilhelm, J ;
Pingoud, A ;
Hahn, M .
BIOTECHNIQUES, 2003, 34 (02) :324-+
[47]   Functional integration of PCR amplification and capillary electrophoresis in a microfabricated DNA analysis device [J].
Woolley, AT ;
Hadley, D ;
Landre, P ;
deMello, AJ ;
Mathies, RA ;
Northrup, MA .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4081-4086
[48]   Socket with built-in valves for the interconnection of microfluidic chips to macro constituents [J].
Yang, Z ;
Maeda, R .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1013 (1-2) :29-33
[49]   Precise temperature control and rapid thermal cycling in a micromachined DNA polymerase chain reaction chip [J].
Yoon, DS ;
Lee, YS ;
Lee, Y ;
Cho, HJ ;
Sung, SW ;
Oh, KW ;
Cha, J ;
Lim, G .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2002, 12 (06) :813-823