Macular Thickness Interoperator and Intraoperator Reproducibility in Healthy Eyes Using 7 Optical Coherence Tomography Instruments

被引:74
作者
Pierro, Luisa [1 ]
Giatsidis, Silvia M. [1 ]
Mantovani, Elena [1 ]
Gagliardi, Marco [1 ]
机构
[1] Univ Vita Salute, San Raffaele Sci Inst, Dept Ophthalmol, I-20132 Milan, Italy
关键词
TIME-DOMAIN; REPEATABILITY;
D O I
10.1016/j.ajo.2010.03.015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate macular thickness measurement reproducibility using 6 new spectral-domain (SD) optical coherence tomography (OCT) devices and 1 time-domain OCT device DESIGN: Prospective, observational study. METHODS: SETTING: Clinical practice. STUDY POPULATION: Macular thickness was assessed in 18 randomly chosen consecutive eyes of 18 healthy volunteers by 2 masked operators using 6 SD OCT devices and 1 time-domain OCT device. MAIN OUTCOME MEASURES: Intraoperator and interoperator reproducibility of OCT-measured central macular thickness. RESULTS: Mean macular thickness ranged from 172.77 to 272.87 mu m. Intraobserver Intraclass coefficient correlation ranged from 0.75 to 0.96. Intraobserver coefficient of variation ranged from 0.44 to 2.75. In Bland-Altman analysis, interoperator mean difference ranged from 0.22 to -9.69. An analysis of variance used for repeated measurement was statistically significant for instruments (P < .001) and operators (P = .04), but not for instruments x operators (P = .32). CONCLUSIONS: The 7 OCT devices presented differing macular thickness measurement values; the lowest value was with Copernicus, and the highest was with Spectralis HRA+OCT (Heidelberg Engineering). The new generation of SD OCT devices has good intraoperator reproducibility, but the Spectralis presents the highest reproducibility together with the best interoperator agreement. The software, and in particular the algorithm, used is the most important factor regarding reproducibility differences in macular thickness measurement. The main result of our study is that macular thickness absolute value differs for each device. For this reason, the devices are not interchangeable. (Am J Ophthalmol 2010;150:199-204. (C) 2010 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:199 / 204
页数:6
相关论文
共 18 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Optical coherence tomography measurements and analysis methods in optical coherence tomography studies of diabetic macular edema [J].
Browning, David J. ;
Glassman, Adam R. ;
Aiello, Lloyd P. ;
Bressler, Neil M. ;
Bressler, Susan B. ;
Danis, Ronald P. ;
Davis, Matthew D. ;
Ferris, Frederick L. ;
Huang, Suber S. ;
Kaiser, Peter K. ;
Kollman, Craig ;
Sadda, Srinavas ;
Scott, Ingrid U. ;
Qin, Haijing .
OPHTHALMOLOGY, 2008, 115 (08) :1366-1371
[3]   Interobserver variability in optical coherence tomography for macular [J].
Browning, DJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (06) :1116-1117
[4]   Spectral domain optical coherence tomography - Ultra-high speed, ultra-high resolution ophthalmic imaging [J].
Chen, TC ;
Cense, B ;
Pierce, MC ;
Nassif, N ;
Park, BH ;
Yun, SH ;
White, BR ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (12) :1715-1720
[5]   Results and repeatability of retinal thickness measurements from certification submissions [J].
Danis, Ronald P. ;
Fisher, Marian R. ;
Lambert, Ericka ;
Goulding, Anne ;
Wu, Deborah ;
Lee, Li-Yin .
ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (01) :45-50
[6]   State-of-the-art retinal optical coherence tomography [J].
Drexler, Wolfgang ;
Fujimoto, James G. .
PROGRESS IN RETINAL AND EYE RESEARCH, 2008, 27 (01) :45-88
[7]   Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema [J].
Forooghian, Farzin ;
Cukras, Catherine ;
Meyerle, Catherine B. ;
Chew, Emily Y. ;
Wong, Wai T. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (10) :4290-4296
[8]   Comparison of time domain Stratus OCT and spectral domain SLO/OCT for assessment of macular thickness and volume [J].
Forte, R. ;
Cennamo, G. L. ;
Finelli, M. L. ;
de Crecchio, G. .
EYE, 2009, 23 (11) :2071-2078
[9]   OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA [J].
HEE, MR ;
IZATT, JA ;
SWANSON, EA ;
HUANG, D ;
SCHUMAN, JS ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) :325-332
[10]   Reproducibility of macular thickness and volume using zeiss optical coherence tomography in patients with diabetic macular edema [J].
Krzystolik, Magdalena G. ;
Strauber, Samara F. ;
Ai-ello, Lloyd Paul ;
Beek, Roy W. ;
Berger, Brian B. ;
Bressler, Neil M. ;
Browning, David J. ;
Chambers, Robert B. ;
Danis, Ronald P. ;
Davis, Matthew D. ;
Glassman, Adam R. ;
Gonzalez, Victor H. ;
Greenberg, Paul B. ;
Gross, Jeffrey G. ;
Kim, Judy E. ;
Kollman, Craig .
OPHTHALMOLOGY, 2007, 114 (08) :1520-1525