Spherical navigator echoes for full 3D rigid body motion measurement in MRI

被引:166
作者
Welch, EB
Manduca, A
Grimm, RC
Ward, HA
Jack, CR
机构
[1] Mayo Clin, Dept Diagnost Radiol, MRI Res Lab, Rochester, MN USA
[2] Mayo Clin, Mayo Grad Sch, Rochester, MN USA
关键词
motion correction; rotation; navigator echo; sphere;
D O I
10.1002/mrm.10012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We developed a 3D spherical navigator (SNAV) echo technique that can measure rigid body motion in all six degrees of freedom simultaneously by sampling a spherical shell in k-space. 3D rotations of an imaged object simply rotate the data on this shell and can be detected by registration of k-space magnitude values. 3D translations add phase shifts to the data on the shell and can be detected with a weighted least-squares fit to the phase differences at corresponding points. MRI pulse sequences were developed to study k-space sampling strategies on such a shelf. Data collected with a computer-controlled motion phantom with known rotational and translational motions were used to evaluate the technique. The accuracy and precision of the technique depend on the sampling density. Roughly 2000 sample points were necessary for accurate detection to within the error limits of the motion phantom when using a prototype time-intensive sampling method. This number of samples can be captured in an approximately 27-ms double excitation SNAV pulse sequence with a 3D helical spiral trajectory. Preliminary results with the helical SNAV are encouraging and indicate that accurate motion measurement suitable for retrospective or prospective correction should be feasible with SNAV echoes. Magn Reson Med 47:32-41, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:32 / 41
页数:10
相关论文
共 31 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[3]   Movement-related effects in fMRI time-series [J].
Friston, KJ ;
Williams, S ;
Howard, R ;
Frackowiak, RSJ ;
Turner, R .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) :346-355
[4]   ORBITAL NAVIGATOR ECHOES FOR MOTION MEASUREMENTS IN MAGNETIC-RESONANCE-IMAGING [J].
FU, ZW ;
WANG, Y ;
GRIMM, RC ;
ROSSMAN, PJ ;
FELMLEE, JP ;
RIEDERER, SJ ;
EHMAN, RL .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (05) :746-753
[5]   PROJECTION RECONSTRUCTION TECHNIQUES FOR REDUCTION OF MOTION EFFECTS IN MRI [J].
GLOVER, GH ;
PAULY, JM .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :275-289
[6]   MOTION ARTIFACTS IN FMRI - COMPARISON OF 2DFT WITH PR AND SPIRAL SCAN METHODS [J].
GLOVER, GH ;
LEE, AT .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :624-635
[7]  
GRIMM RC, 1997, P 5 ANN M ISMRM VANC, P1899
[8]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[9]   ARTIFACTS DUE TO STIMULUS CORRELATED MOTION IN FUNCTIONAL IMAGING OF THE BRAIN [J].
HAJNAL, JV ;
MYERS, R ;
OATRIDGE, A ;
SCHWIESO, JE ;
YOUNG, IR ;
BYDDER, GM .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (03) :283-291
[10]   Hybrid ordered phase encoding (HOPE): An improved approach for respiratory artifact reduction [J].
Jhooti, P ;
Wiesmann, F ;
Taylor, AM ;
Gatehouse, PD ;
Yang, GZ ;
Keegan, J ;
Pennell, DJ ;
Firmin, DN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :968-980