Highly sensitive regenerable immunosensor for label-free detection of 2,4-dichlorophenoxyacetic acid at ppb levels by using surface plasmon resonance imaging

被引:47
作者
Gobi, KV [1 ]
Tanaka, H
Shoyama, Y
Miura, N
机构
[1] Kyushu Univ, Art Sci & Technol Ctr Cooperat Res, Kasuga, Fukuoka 8168580, Japan
[2] JSPS, Tokyo, Japan
[3] Kyushu Univ, Grad Sch Pharmaceut Sci, Higashi, Fukuoka 8128582, Japan
关键词
2,4-dichlorophenoxyacetic acid; surface plasmon resonance sensor; immunoassay; endocrine disruptors; pepsin;
D O I
10.1016/j.snb.2005.03.118
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports the characteristics of a newly developed optical surface plasmon resonance (SPR) immunosensor for direct, label-free detection of 2,4-dichlorophenoxyacetic acid (2,4-D). The analyte 2,4-D is conjugated with bovine serum albumin (BSA) protein, and the analyte-BSA conjugate is immobilized on to the thin gold-film SPR sensor chip mounted in a continuous flow system by simple physical adsorption. The thin biofilm of 2,4-D-BSA formed on the sensor chip is characterized a monomolecular layer of 2,4-D-BSA conjugate. Functionalization of sensor surface by physical adsorption of 2,4-D-BSA conjugate and followed immunoreaction of surface-bound 2,4-D-BSA with a monoclonal anti-2,4-D-BSA antibody (2,4-D-Ab) are Studied by SPR angle interrogation method. The antibody 2,4-D-Ab immobilizes firmly through selective immunoreaction over the 2,4-D-BSA physisorbed SPR sensor chip. Flow of a general protein such as BSA or a non-related antibody over the 2,4-D-BSA immobilized sensor chip showed negligible response indicating the resistivity of the sensor surface to non-selective adsorption of proteins. The quantification of free 2,4-D is based on competitive immunoassay format, which is performed by co-injecting the sample and the monoclonal antibody 2,4-D-Ab over the 2,4-D-BSA physisorbed thin gold-film SPR chip and measuring the amount of specifically bound monoclonal antibodies. When free 2,4-D molecules present in the analyte solution, competition between free 2,4-D and surface-bound 2,4-D-BSA conjugate for binding to 2,4-D-Ab decreases the affinity interaction of the antibody with the sensor surface. The change in the SPR angle in the presence of 2,4-D is inversely proportional to the concentration of 2,4-D coexisting. Such an analytical system has been shown to be capable of detecting concentrations of 2,4-D in buffer as low as 0.5 ng/ml (ppb) with a response time of 20 min, and the 2,4-D detection is possible in the concentration range from 0.5 ng/ml to 1 mu g/ml (ppm). We used in this investigation a simple SPR instrument, which is not equipped with either regulated flow system or temperature-controller and is similar to a portable SPR analyzer. After an immunoaffinity binding test, the active sensor surface can be regenerated again by simply flowing a chaotropic solution of pepsin (10 ppm in 0.2 M glycine-HCl buffer (pH 2.0)) in the flow system for just 2 min. This regeneration ability enables the achievement of as much as 20 measurement cycles of 2,4-D using a single 2,4-D-BSA conjugate immobilized SPR sensor chip with good reproducibility. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:562 / 571
页数:10
相关论文
共 68 条
[31]   Formation of a self-assembled phenylboronic acid monolayer and its application toward developing a surface plasmon resonance-based monosaccharide sensor [J].
Lee, M ;
Kim, TI ;
Kim, KH ;
Kim, JH ;
Choi, MS ;
Choi, HJ ;
Koh, K .
ANALYTICAL BIOCHEMISTRY, 2002, 310 (02) :163-170
[32]   Fabrication of self-assembled protein A monolayer and its application as an immunosensor [J].
Lee, W ;
Oh, BK ;
Bae, YM ;
Paek, SH ;
Lee, WH ;
Choi, JW .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (03) :185-192
[33]   Structural conformation of bovine serum albumin layers at the air-water interface studied by neutron reflection [J].
Lu, JR ;
Su, TJ ;
Thomas, RK .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1999, 213 (02) :426-437
[34]   Carbon and gold electrodes as electrochemical transducers for DNA hybridisation sensors [J].
Lucarelli, F ;
Marrazza, G ;
Turner, APF ;
Mascini, M .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (06) :515-530
[35]   Simplified urinary immunoassay for 2,4-D: Validation and exposure assessment [J].
Lyubimov, AV ;
Garry, VF ;
Carlson, RE ;
Barr, DB ;
Baker, SE .
JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 2000, 136 (02) :116-124
[36]   Regenerable immunobiosensor for the chemiluminescent flow injection analysis of the herbicide 2,4-D [J].
Marquette, CA ;
Blum, LJ .
TALANTA, 2000, 51 (02) :395-401
[37]  
Matsumura F., 1994, INT ENCY PHARM THERA, P453
[38]   DETECTION OF PESTICIDE IN DRINKING-WATER USING REAL-TIME BIOSPECIFIC INTERACTION ANALYSIS (BIA) [J].
MINUNNI, M ;
MASCINI, M .
ANALYTICAL LETTERS, 1993, 26 (07) :1441-1460
[39]   Regenerable surface plasmon resonance (SPR)-based immunosensor for highly sensitive measurement of sub-ppb levels of benzo(a)pyrene [J].
Miura, N ;
Sasaki, M ;
Sakai, G ;
Gobi, KV .
CHEMISTRY LETTERS, 2002, (03) :342-343
[40]   PIEZOELECTRIC CRYSTAL IMMUNOSENSOR FOR SENSITIVE DETECTION OF METHAMPHETAMINE (STIMULANT DRUG) IN HUMAN URINE [J].
MIURA, N ;
HIGOBASHI, H ;
SAKAI, G ;
TAKEYASU, A ;
UDA, T ;
YAMAZOE, N .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) :188-191