Speciation analysis of antimony by high-performance liquid chromatography inductively coupled plasma mass spectrometry using ultrasonic nebulization

被引:62
作者
Krachler, M [1 ]
Emons, H [1 ]
机构
[1] Res Ctr Juelich, Inst Appl Phys Chem, D-52425 Julich, Germany
关键词
antimony; speciation; high-performance liquid chromatography; inductively coupled plasma mass spectrometry; ultrasonic nebulization;
D O I
10.1016/S0003-2670(00)01252-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The two inorganic Sb species Sb(III) and Sb(V) as well as trimethlyantimony dichloride (TMSbCl2) were separated by anion exchange chromatography. HPLC eluents were directly aspirated into the plasma of an ICP-MS using ultrasonic nebulization (USN) with membrane desolvation. Leaching of Sb from glass bottles, especially pronounced under alkaline conditions, distinctly increased background Sb-121 signals. The use of conventional HPLC syringes made of glass resulted in non reproducible blank signals for Sb(V). To overcome these problems, polyethylene bottles for the storage of mobile phases and plastic syringes for the injection of Sb compounds onto the analytical columns were employed. The analysis of Sb(III) standard solutions in the sub mu gl(-1) range prepared by dilution of stock standard solutions with high-purity water revealed that Sb(III) is easily oxidized to Sb(V) within a few hours. Deoxygenating the water for dilution of standards by flashing working standard solution with helium or using 1.25 mM EDTA - which served as mobile phase for the chromatographic separation - for the dilution of standards, no oxidation of Sb(III) was observed, at least for 8 h. USN parameters, such as the temperature of the heating area and of the desolvation area as well as the sweep gas flow rate were systematically optimized. Decreasing the USN heating temperature from the conventional settings of 140-80 degreesC enhanced signal intensities by similar to 25% and caused no condensation of the aspirated mobile phase. After optimization detection limits for all three Sb species in the low ng l(-1) range could be established, namely 14 ngl(-1) for Sb(III), 12 ngl(-1) for Sb(V) and 9 ngl(-1) for TMSbCl2. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:125 / 133
页数:9
相关论文
共 21 条
[11]   Potential of high performance liquid chromatography coupled to flow injection hydride generation atomic absorption spectrometry for the speciation of inorganic and organic antimony compounds [J].
Krachler, M ;
Emons, H .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (03) :281-285
[12]   Influence of sample pre-treatment on the determination of trace elements in urine by quadrupole and magnetic sector field inductively coupled plasma mass spectrometry [J].
Krachler, M ;
Alimonti, A ;
Petrucci, F ;
Forastiere, F ;
Caroli, S .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (08) :701-705
[13]  
KRACHLER M, IN PRESS FRESENIUS J
[14]   Simultaneous determination of arsenic, selenium and antimony species using HPLC/ICP-MS [J].
Lindemann, T ;
Prange, A ;
Dannecker, W ;
Neidhart, B .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (05) :462-466
[15]   The analysis of antimony species by using ESI-MS and HPLC-ICP-MS [J].
Lintschinger, J ;
Schramel, O ;
Kettrup, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 361 (02) :96-102
[16]   Determination of antimony species with high-performance liquid chromatography using element specific detection [J].
Lintschinger, J ;
Koch, I ;
Serves, S ;
Feldmann, J ;
Cullen, WR .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (06) :484-491
[17]  
NASH JM, 2000, J ENVIRON MONITOR, V2, P97
[18]   SEPARATION AND DETERMINATION OF ANTIMONY(III) AND ANTIMONY(V) SPECIES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRIC AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETECTION [J].
SMICHOWSKI, P ;
MADRID, Y ;
GUNTINAS, MBD ;
CAMARA, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (10) :815-821
[19]   Speciation of antimony(III), antimony(V) and trimethylstiboxide by ion chromatography with inductively coupled plasma atomic emission spectrometric and mass spectrometric detection [J].
Ulrich, N .
ANALYTICA CHIMICA ACTA, 1998, 359 (03) :245-253
[20]   Speciation of antimony(III) and antimony(V) species by using high-performance liquid chromatography coupled to hydride generation atomic absorption spectrometry [J].
Zhang, XR ;
Cornelis, R ;
Mees, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (03) :205-207