Evaluation of a stereotactic frame for repositioning of the rat brain in serial positron emission tomography imaging studies

被引:25
作者
Rubins, DJ [1 ]
Meadors, AK [1 ]
Yee, S [1 ]
Melega, WP [1 ]
Cherry, SR [1 ]
机构
[1] Univ Calif Los Angeles, Sch Med, Crump Inst Mol Imaging, Dept Mol & Med Pharmacol, Los Angeles, CA USA
关键词
in vivo imaging of small animals; positron emission tomography; image data analysis; imaging instrumentation; rat model of disease; neuroimaging; stereotactic head holder;
D O I
10.1016/S0165-0270(01)00352-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For serial imaging studies of the rat brain with positron emission tomography (PET), reproducible positioning of the head can facilitate spatial alignment of images and quantitative analysis. To achieve this aim, we constructed a plastic head frame and tested the positioning reproducibility on a high-resolution small-animal PET scanner, microPET. Two sets of ear bars, with tapers of either 18 degrees (sharp) or 45 degrees (blunt), were evaluated for their relative precision in securing the animal to the frame. For sequential positioning of an animal, average distances from the mean position of 0.51 mm (SD 0.41 mm) and 0.91 mm (SD 0.48 mm) were measured with the sharp and blunt ear bars, respectively. These results show that a rat brain can be reproducibly positioned using the frame, with a variation of position less than the spatial resolution of modern animal PET scanners. Brain regions of interest defined on one scan and copied across subsequent scans of a frame-repositioned animal resulted in an average coefficient of variation of 5.4% (SD 2.7%) using the sharp ear bars and 6.8% (SD 2.5%) using the blunt ear bars. This methodology has the potential to improve quantitative assessment for serial PET studies. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:63 / 70
页数:8
相关论文
共 17 条
[1]   THE DESIGN AND PHYSICAL CHARACTERISTICS OF A SMALL ANIMAL POSITRON EMISSION TOMOGRAPH [J].
BLOOMFIELD, PM ;
RAJESWARAN, S ;
SPINKS, TJ ;
HUME, SP ;
MYERS, R ;
ASHWORTH, S ;
CLIFFORD, KM ;
JONES, WF ;
BYARS, LG ;
YOUNG, J ;
ANDREACO, M ;
WILLIAMS, CW ;
LAMMERTSMA, AA ;
JONES, T .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (06) :1105-1126
[2]   In vivo PET imaging in rat of dopamine terminals reveals functional neural transplants [J].
Brownell, AL ;
Livni, E ;
Galpern, W ;
Isacson, O .
ANNALS OF NEUROLOGY, 1998, 43 (03) :387-390
[3]   Comparison of 3-D maximum a posteriori and filtered backprojection algorithms for high-resolution animal imaging with microPET [J].
Chatziioannou, A ;
Qi, J ;
Moore, A ;
Annala, A ;
Nguyen, K ;
Leahy, R ;
Cherry, SR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) :507-512
[4]  
Chatziioannou AF, 1999, J NUCL MED, V40, P1164
[5]   MicroPET: A high resolution PET scanner for imaging small animals [J].
Cherry, SR ;
Shao, Y ;
Silverman, RW ;
Meadors, K ;
Siegel, S ;
Chatziioannou, A ;
Young, JW ;
Jones, WF ;
Moyers, JC ;
Newport, D ;
Boutefnouchet, A ;
Farquhar, TH ;
Andreaco, M ;
Paulus, MJ ;
Binkley, DM ;
Nutt, R ;
Phelps, ME .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1161-1166
[6]  
Hirani E, 2000, SYNAPSE, V36, P330, DOI 10.1002/(SICI)1098-2396(20000615)36:4<330::AID-SYN10>3.0.CO
[7]  
2-H
[8]   A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals [J].
Jeavons, AP ;
Chandler, RA ;
Dettmar, CAR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :468-473
[9]   In vivo imaging of neuronal activation and plasticity in the rat brain by high resolution positron emission tomography (microPET) [J].
Kornblum, HI ;
Araujo, DM ;
Annala, AJ ;
Tatsukawa, KJ ;
Phelps, ME ;
Cherry, SR .
NATURE BIOTECHNOLOGY, 2000, 18 (06) :655-660
[10]   DESIGN AND ENGINEERING ASPECTS OF A HIGH-RESOLUTION POSITRON TOMOGRAPH FOR SMALL ANIMAL IMAGING [J].
LECOMTE, R ;
CADORETTE, J ;
RICHARD, P ;
RODRIGUE, S ;
ROULEAU, D .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) :1446-1452