Square stent:: A new self-expandable endoluminal device and its applications

被引:18
作者
Pavcnik, D [1 ]
Uchida, B [1 ]
Timmermans, H [1 ]
Keller, FS [1 ]
Rösch, J [1 ]
机构
[1] Oregon Hlth & Sci Univ, Dotter Intervent Inst, Portland, OR 97201 USA
关键词
stents and prostheses; filters; interventional procedures; embolism; pulmonary; embolization; endovascular stent graft; venous valve; aortic valve; biomaterial;
D O I
10.1007/s00270-001-0041-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The square stent is a new, simply constructed, self-expanding device that has recently been described. Compared with other stents, the square stent has a minimal amount of metal and thus requires a smaller-diameter catheter for introduction. Despite the small amount of metal present, the square stent has adequate expansile force. We have been evaluating the square stent for various interventional. applications. In addition to the basic square stent, combinations of square stents and coverings for square stents were developed and evaluated to expand its uses and indications. One of the coverings tested is a new biomaterial: small intestinal submucosa (SIS). This paper will discuss the various applications of the square stent, which include a retrievable inferior vena cava filter, vascular occluder, graft adapter, and venous and aortic valves. In addition, we will review the important properties of SIS as a covering for the square stent.
引用
收藏
页码:207 / 217
页数:11
相关论文
共 20 条
  • [1] AIKEN SW, 1994, VET COMP ORTHOPAED, V7, P124
  • [2] BADYLAK SF, 1993, TISSUE ENGINEERING, P179
  • [3] SMALL INTESTINAL SUBMUCOSA AS A LARGE DIAMETER VASCULAR GRAFT IN THE DOG
    BADYLAK, SF
    LANTZ, GC
    COFFEY, A
    GEDDES, LA
    [J]. JOURNAL OF SURGICAL RESEARCH, 1989, 47 (01) : 74 - 80
  • [4] MECHANICAL-PROPERTIES OF XENOGENEIC SMALL-INTESTINAL SUBMUCOSA WHEN USED AS AN AORTIC GRAFT IN THE DOG
    HILES, MC
    BADYLAK, SF
    LANTZ, GC
    KOKINI, K
    GEDDES, LA
    MORFF, RJ
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (07): : 883 - 891
  • [5] BIOCOMPATIBILITY OF SMALL-INTESTINAL SUBMUCOSA IN URINARY-TRACT AS AUGMENTATION CYSTOPLASTY GRAFT AND INJECTABLE SUSPENSION
    KNAPP, PM
    LINGEMAN, JE
    SIEGEL, YI
    BADYLAK, SF
    DEMETER, RJ
    [J]. JOURNAL OF ENDOUROLOGY, 1994, 8 (02) : 125 - 130
  • [6] Lantz G C, 1993, J Invest Surg, V6, P297, DOI 10.3109/08941939309141619
  • [7] MCGEE P, 1998, ORTHOPEDICS TODAY, V18, P43
  • [8] Small intestinal submucosa covered expandable Z stents for treatment of tracheal injury:: An experimental pilot study in swine
    Park, JW
    Pavcnik, D
    Uchida, BT
    Timmermans, H
    Corless, CL
    Yamakado, K
    Yamada, K
    Keller, FS
    Rösch, J
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (10) : 1325 - 1330
  • [9] Retrievable IVC square stent filter:: Experimental study
    Pavcnik, D
    Uchida, BT
    Keller, FS
    Corless, CL
    Rösch, J
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 22 (03) : 239 - 245
  • [10] Pavcnik D, 2000, MINIM INVASIV THER, V9, P287, DOI 10.1080/13645700009169659