A multiple-capillary electrophoresis system for smallscale DNA sequencing and analysis

被引:61
作者
Zhang, Jianzhong [1 ]
Voss, Karl O. [1 ]
Shaw, Diana F. [1 ]
Roos, K. Pieter [1 ]
Lewis, Darren F. [1 ]
Yan, Juying [1 ]
Jiang, Rong [1 ]
Ren, Hongji [1 ]
Hou, Joan Y. [1 ]
Fang, Yu [1 ]
Puyang, Xiaoling [1 ]
Ahmadzadeh, Hossein [1 ]
Dovichi, Norman J. [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1093/nar/27.24.e36
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A five-capillary system has been developed for DNA sequencing and analysis. The post-column fluorescence detector is based on a sheath-flow cuvette. The instrument provides uniform and continuous illumination of the samples. The cuvette virtually eliminates cross-talk in the fluorescence signal between capillaries. Discrete single-photon counting avalanche photodiodes provide high efficiency light detection. The instrument has detection limits (3 sigma) of 130 +/- 30 fluorescein molecules injected onto each capillary. Over 650 bases of sequence at 98.8% accuracy were generated in 100 min at 50 degrees C from M13mp18. Separation and detection of short tandem repeats proved efficient and accurate with the use of internal standards for direct comparison of migration times between capillaries.
引用
收藏
页数:7
相关论文
共 30 条
[11]  
HUNKAPILLER T, 1991, SCIENCE, V254, P67
[12]   MULTIPLE-SHEATHFLOW CAPILLARY ARRAY DNA ANALYZER [J].
KAMBARA, H ;
TAKAHASHI, S .
NATURE, 1993, 361 (6412) :565-566
[13]   MULTIWAVELENGTH FLUORESCENCE DETECTION FOR DNA SEQUENCING USING CAPILLARY ELECTROPHORESIS [J].
KARGER, AE ;
HARRIS, JM ;
GESTELAND, RF .
NUCLEIC ACIDS RESEARCH, 1991, 19 (18) :4955-4962
[14]   ESTIMATION OF THE LIMIT OF DETECTION IN CHROMATOGRAPHY [J].
KNOLL, JE .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1985, 23 (09) :422-425
[15]   OPTIMIZATION OF EXCITATION AND DETECTION GEOMETRY FOR MULTIPLEXED CAPILLARY ARRAY ELECTROPHORESIS OF DNA FRAGMENTS [J].
LU, XD ;
YEUNG, ES .
APPLIED SPECTROSCOPY, 1995, 49 (05) :605-609
[16]   OPTIMIZATION OF ELECTRIC-FIELD STRENGTH FOR DNA-SEQUENCING IN CAPILLARY GEL-ELECTROPHORESIS [J].
LUCKEY, JA ;
SMITH, LM .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2841-2850
[17]   CAPILLARY ARRAY ELECTROPHORESIS - AN APPROACH TO HIGH-SPEED, HIGH-THROUGHPUT DNA SEQUENCING [J].
MATHIES, RA ;
HUANG, XC .
NATURE, 1992, 359 (6391) :167-169
[18]   Multiple capillary DNA sequencer that uses fiber-optic illumination and detection [J].
Quesada, MA ;
Zhang, SP .
ELECTROPHORESIS, 1996, 17 (12) :1841-1851
[19]   SEPARATION OF DNA SEQUENCING FRAGMENTS AT 53 BASES MINUTE BY CAPILLARY GEL-ELECTROPHORESIS [J].
ROCHELEAU, MJ ;
DOVICHI, NJ .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1992, 4 (05) :449-453
[20]   FORMAMIDE MODIFIED POLYACRYLAMIDE GELS FOR DNA SEQUENCING BY CAPILLARY GEL-ELECTROPHORESIS [J].
ROCHELEAU, MJ ;
GREY, RJ ;
DA, YC ;
HARKE, HR ;
DOVICHI, NJ .
ELECTROPHORESIS, 1992, 13 (08) :484-486